ACiQ 3.5 Ton 16.7 SEER2 High Efficiency Central Heat Pump | Inverter | Extreme Series - R454B

ACiQ 3.5 Ton 16.7 SEER2 High Efficiency Central Heat Pump | Inverter | Extreme Series - R454B
ACIQ
SKU:
ACiQ-42-HPD-9CE02F

Additional Information

AC Type:
Heat Pump Condensers
Refrigerant Type:
R454B
Voltage:
208-230V
SEER2 Rating:
16.7
New
$3,119.99
Adding to cart… The item has been added

ACiQ
ACiQ 3.5 Ton 16.7 SEER2 High Efficiency Central Heat Pump | Inverter | Extreme Series - R454B

Product Overview

OVERVIEW

Inverter - The ACIQ-42-HPD 3.5 ton Extreme series central inverter heat pump utilizes inverter technology to convert AC power to DC, allowing the compressor inside your condenser to speed up and slow down. This allows the system to self-adjust BTU output based on demand. As the weather changes, so will your system output.

Learning Condenser - Equipped with advanced sensors, this condenser monitors indoor and outdoor air temperature, duct pressure, refrigerant temperature, and overall performance. During the initial startup, it enters a learning mode that optimizes future operations for maximum efficiency by collecting and storing data.

Adaptive Sizing - With its self-adjusting inverter design, the ACIQ-42-HPD can be sized based on your heating needs. Standard heat pumps may cause discomfort during summer when sized for heat, but this unit automatically adjusts to function like a smaller unit, ensuring ideal cooling performance without excess humidity.

Extreme Heat Technology - "Extreme Heat" means extended temperature range heating all the way down to -22°F. Traditional heat pumps cannot produce significant heat below about 30°F outside temperature. Below that threshold, they rely on expensive backup electric heat. The ACIQ-42-HPD uses the inverter to vary the refrigerant flow, allowing for maximum heat extraction during extreme cold temperatures. The backup electric heat supplements the heat pump, and only takes over below -22°F. The heat pump gives 100% at 0°F, and still gives 80% at -22°F, saving you up to 75% on cold weather heating bills.

QUICK FACTS

  • Variable BTU output based on demand: 12,000-42,000 BTU for cooling, 12,000-50,000 for heating
  • R454B refrigerant
  • Inverter heat pump system for ducted applications
  • Efficient cooling from -22°F to 122°F outdoor temperatures
  • Efficient heating from -22°F to 75°F outdoor temperatures
  • Durable gold fin condenser coil coating for longevity
  • Quiet operation, even under high workloads

3.5 Ton, 16.7 SEER2

Boasting an efficiency rating of 16.7 SEER2, the ACIQ-42-HPD provides versatile comfort across a range of climates by providing reliable comfort with a variable output that eliminates short cycling for lasting efficiency. Use our sizing calculator (found ) to determine the demand for your home.


Extreme Heat Base Pan Heater Technology

Each ACiQ condenser has integrated Extreme Heat technology to maximize heat performance in extreme cold weather. Extended heat pump performance (HyperHeat) harnesses the power of inverter condenser with outdoor temp sensing, variable refrigerant flow and variable condenser fan speed to maximize heat extraction all the way down to -22°F. Plus, every Extreme Heat ACiQ condenser includes a base pan heater to keep ice from collecting on the condenser coil during heat pump operation.


Quality Construction

State-of-the-Art manufacturing is behind every ACiQ product, resulting in quiet, effective operation over a long service life. Most models have low ambient heating and cooling.


Highest Efficiency

ACiQ saves you money up front, but also over time by reducing energy bills. Every ACiQ condenser features a variable inverter twin rotary compressor, lowering wear and increasing performance. Compare specs against other brands in the same price category, and you will agree, ACiQ is the best value.


Longer life, longer warranty

Intelligent design goes into every element of ACiQ’s manufacturing ensuring flawless performance for years. Low friction, variable inverter twin rotary compressors give bulletproof reliability. Register equipment at ACiQ.com to extend warranty protection to 7 years parts, 12 years compressor.

Technical Specifications — ACiQ-42-HPD

sku ACiQ-42-HPD
refrigerant charge 25'
weight 232.360000
manufacturer ACiQ
replaces ACiQ-42-HPB
product features Inverter, Low Ambient Heating, Two Stage Condenser, Variable Speed Condenser
hspf2 9.5
cooling btu 42,000 BTU
heating btu 50,000 BTU
maximum cfm 3037
decibel level (dba) 65
electric heat Heat Pump
refrigerant R454B
seer2 16.7
condenser stages Variable Speed
compressor type Rotary
liquid valve size "3/8""
suction valve size "3/4""
electrical 208/230V 1 Phase 60 Hz
max breaker size 40 Amps
min. breaker size 38 Amps
tonnage 3.5 Ton
btu/tonnage 42,000 BTU/3.5 Ton
min/max outdoor temp for heating -22°F - 75°F
min/max outdoor temp for cooling -22°F - 122°F
ambient temperature range -22°F - 122°F
height "38.4""
width "38.6""
depth "16.3""
warranty 12 Years Compressor and 7 Years Parts with Online Registration