ACIQ 55,000 BTU 22.2 SEER2 ACiQ Multi Zone Condenser Extreme Series| R454B

ACIQ 55,000 BTU 22.2 SEER2 ACiQ Multi Zone Condenser Extreme Series| R454B
ACIQ
SKU:
ACIQ-55Z-HH-M6C-1733CE

Additional Information

AC Type:
Multi-zone Condenser
Refrigerant Type:
R454B
Voltage:
208-230V
SEER2 Rating:
22.2
Energy Star:
Yes
New
$5,199.99
Adding to cart… The item has been added

ACIQ
ACIQ 55,000 BTU 22.2 SEER2 ACiQ Multi Zone Condenser Extreme Series| R454B

Product Overview

OVERVIEW

ACIQ is the smart solution to adaptive heating and cooling in almost any space and climate -all at an affordable cost. With the ACIQ-55z-HH-M6C, you can have up to 6 air handlers run off a single condenser, saving space outside and keeping you perfectly comfortable in your home.

QUICK FACTS

  • 55,000 BTU, 22.2 SEER2 multi zone heat pump condenser
  • Designed to function with up to 6 attached air handlers
  • Efficient cooling from -22°F to 122°F outdoor temperatures
  • Efficient heating from -22°F to 75°F outdoor temperatures
  • Integrated Extreme Heat technology with base pan heater
  • Gold Fin full-protection coating on condenser coil
  • Quiet operation at even the highest workloads

55,000 BTU, 22.2 SEER2

The 55,000 BTU, ACIQ-55z-HH-M6C is designed to easily support up to 4 air handlers at up to 1.25 times the condenser BTU rating, or 60,000 BTU across all air handlers. This adaptive, inverter condenser is constantly self-adjusting to provide the precise amount of heating or cooling needed to maintain your desired temperature in each room or zone. You can set different temperatures room by room, even turn off heating and cooling in unused areas. This, combined with a high efficiency rating of 22.2 SEER2, means you are buying a system designed to intelligently save you money both up front and over the lifetime of the unit.

Although the condenser is pre-charged, please note that this model of equipment does not have quick connect line set connectors and is not a self-install unit. You will need a professional to add more refrigerant and vacuum the lines as needed. Installation materials such as line sets, control wire, drain hose, whip and disconnect are not included, but are available at additional cost in the Accessories section to the right of this text. For all multi zone ACIQ condensers, a minimum of two air handlers is needed for the unit to function.


Extreme Heat Base Pan Heater Technology

Each ACiQ condenser has integrated Extreme Heat technology to maximize heat performance in extreme cold weather. Extended heat pump performance (HyperHeat) harnesses the power of inverter condenser with outdoor temp sensing, variable refrigerant flow and variable condenser fan speed to maximize heat extraction all the way down to -22°F. Plus, every Extreme Heat ACiQ condenser includes a base pan heater to keep ice from collecting on the condenser coil during heat pump operation.


Quality Construction

State-of-the-Art manufacturing is behind every ACiQ product, resulting in quiet, effective operation over a long service life. Most models have low ambient heating and cooling.


Highest Efficiency

ACiQ saves you money up front, but also over time by reducing energy bills. Every ACiQ condenser features a variable inverter twin rotary compressor, lowering wear and increasing performance. Compare specs against other brands in the same price category, and you will agree, ACiQ is the best value.


Longer life, longer warranty

Intelligent design goes into every element of ACiQ’s manufacturing ensuring flawless performance for years. Low friction, variable inverter twin rotary compressors give bulletproof reliability. Register equipment at ACiQ.com to extend warranty protection to 7 years parts, 12 years compressor.


Installation and Maintenance

ACiQ multi zone condensers are pre-charged with R410-A refrigerant for 25' per air handler connection. In many cases, no additional refrigerant is needed. All units are run-tested at the factory for years of trouble-free performance. Troubleshooting is easy thanks to unit's self diagnosing control board with alerts that are sent to each connected air handler.

Technical Specifications — ACIQ-55Z-HH-M6C

sku ACIQ-55Z-HH-M6C
refrigerant charge 151.68 oz.
weight (in lbs) 276.680000
ahri certificate number 216032373
brand/manufacturer ACiQ
replaces ACIQ-55Z-HH-M5B
product features Low Ambient Heating
hspf2 10.5
cooling btu 51000
heating btu 55000
maximum cfm 4503
decibel level (dba) 65
electric heat Heat Pump
energy star Yes
refrigerant R454B
seer2 (efficiency) 22.2
compressor type Twin Rotary
liquid line 1/4" (6)
suction line 3/8" (4); 1/2" (2)
electrical 208/230V, 1 Phase, 60 Hz
phase Single Phase
max breaker size 40A
min. breaker size 39.5A
tonnage 4.5 Ton
btu/tonnage 55,000 BTU/4.5 Ton
mini split type Wall Mounted
zone compatibility Multi Zone
height 52.48"
width 37.48"
depth 16.34"
warranty 12 year compressor, 7 year parts with online registration
safety information PROPOSITION 65 WARNINGThis product and many products on our site may contain a chemical know to the state of California to cause cancer or birth defects or other reproductive harm. For more information about Proposition 65 pleaseClick Here.