Condensate Pump — AB-C-PUMP-24P
Highlights
- Ultra-silent performance: Low noise operation at 17 dB(A) @ 1 m.
- Reliable drainage: Up to 24 L/H max flow with 15 m max discharge head.
- Built-in level meter: Supports stable operation and responsive drainage control.
- Double control design: Designed for dependable condensate handling and system protection.
- Built-in indicator: Quick status visibility during operation and service.
- Water overflow alarm: Added protection to help prevent overflow events.
- Wide-range power: 110–240V, AC 50/60Hz.
Specifications
| Spec | Value |
|---|---|
| Voltage / Frequency | 110–240V AC, 50/60Hz |
| Max flow | 24 L/H |
| Sound level | 17 dB(A) @ 1 m |
| Max discharge head | 15 m |
| Safety switch | 3A |
| Max water temperature | 140°F |
| Tank capacity | 75 mL |
Dimensions & Weight
| Box size (in) | Net weight | Gross weight |
|---|---|---|
| 10.23 × 6.69 × 2.52 | 0.89 lb | 1.13 lb |
Description
The Armbridge AB-C-PUMP-24P Condensate Pump delivers reliable condensate removal with durable construction and ultra-silent operation. Designed with a built-in level meter, double control design, and clear operating indicator, it helps keep condensate moving safely away from your HVAC equipment. An integrated overflow alarm adds an extra layer of protection in the event of abnormal water rise.
Installation and wiring should be performed by a qualified technician/electrician and must follow local code requirements.
Troubleshooting Q&A
Practical checks to resolve common condensate pump issues.
| Symptom | Possible cause | Recommended action |
|---|---|---|
| Pump running successively | 1) Water box is not at horizontal level 2) Mud or debris in water box or the probe |
Adjust the level of the water box Clean the box and probe |
| Noisy when starting or stopping | 1) Syphon in the pump | Check if the outlet entrance of the pump is lower than pump height (causing syphon) and adjust the position of the outlet entrance. |
| Pump is running but no water drained | 1) Air leakage at the connection hose 2) Inlet hose of the pump blocking |
Check if there is air leakage between water box and the pump. Check if the water box, filter, and inlet hose are blocked by mud or debris. |
| Pump malfunction | 1) Water box is not at horizontal level 2) Inadequate power supply 3) Voltage error 4) Wire connection error 5) Mini motor emits heat and thermal cut-off protection |
Adjust the level of the water box Check the power supply Check the voltage Check the wire connection Check the thermal cut-off device |
Maintenance Tip
Proper use and maintenance will improve the lifespan of the pump. Clean the condensing drain pump during seasonal changeover or before the next season of use.