Summary
The Cooper&Hunter Universal Floor/Ceiling units provide a versatile cooling and heating solution, suitable for both ceiling and wall installations. These units are engineered for flexibility, allowing placement horizontally on ceilings or vertically on walls to meet diverse architectural needs.
Available in capacities of 18K, 24K, 36K, 48K, and 60K BTU/h, these systems are designed for both single-zone and multi-zone applications, offering high efficiency with ratings of up to 23 SEER. This adaptability makes them perfect for various settings, from residential to commercial spaces.
The installation is streamlined and discreet, ensuring the units blend seamlessly into any environment without compromising interior aesthetics. Additionally, these systems can operate efficiently in extreme conditions, heating effectively in ambient temperatures as low as -13°F for standard units and up to -22°F for Hyper Units.
Control options include a remote control and wall thermostat enhancing user comfort and ease of use. These features, combined with their flexible installation options, make the Universal Floor/Ceiling units an excellent choice for those seeking efficient and adaptable heating and cooling solutions.
Important
All units must be installed by a licensed HVAC professional for the warranty to be valid. Registration is required within 60 days of installation and can be completed online or by phone. The installation kit is necessary for the system to function. Ensure that you have selected the desired installation kit above. This kit comes with Pre-Flared 99% Copper Lines, Data Communication Wires, PVC Drainage Attachment, Wrapping Bands, etc.
What's Included
- Indoor Unit CH-RSH18MFC (18,000 BTU 230V Universal Floor/Ceiling Air Conditioning Unit)
- Optional, Pre-Flared 99% Copper Installation Kit (16ft, 25ft or 50ft.) MUST BE SELECTED ABOVE.
- Wireless Remote Control
- Thermostat included
- Installation Manual
- User’s Manual
- Manufacturer Warranty
Compatible Standard Outdoor Units
| Capacity | BTU | SKU |
| Dual/Tri (2 or 3) Zone: | 18,000 BTU |
CH-R18MES-230VO
|
| Dual/Tri/Quad (2, 3 or 4) Zone: | 28,000 BTU |
CH-R28MES-230VO
|
| Dual/Tri/Quad/Pent (2, 3, 4 or 5) Zone: | 36,000 BTU |
CH-R36MES-230VO
|
| Dual/Tri/Quad/Pent/Hexa (2, 3, 4, 5 or 6) Zone: | 48,000 BTU |
CH-R48MES-230VO
|
| Dual/Tri/Quad/Pent/Hexa (2, 3, 4, 5 or 6) Zone: | 55,000 BTU |
CH-R60MES-230VO
|
Compatible Hyper Outdoor Units
| Capacity | BTU | SKU |
| Dual/Tri (2 or 3) Zone: | 19,000 BTU |
CH-RVHP19M-230VO
|
| Dual/Tri/Quad (2, 3 or 4) Zone: | 28,000 BTU |
CH-RVHP28M-230VO
|
| Dual/Tri/Quad/Pent (2, 3, 4 or 5) Zone: | 36,000 BTU |
CH-RVHP36M-230VO
|
| Dual/Tri/Quad/Pent/Hexa (2, 3, 4, 5 or 6) Zone: | 48,000 BTU |
CH-RVHP48M-230VO
|
| Dual/Tri/Quad/Pent/Hexa (2, 3, 4, 5 or 6) Zone: | 55,000 BTU |
CH-RVHP55M-230VO
|
Sizing and Compatibility:
Combination Chart
The capacity and number of systems can vary for each outdoor unit. Consult the combination chart for potential loading configurations. Ensure the total capacity of all connected indoor units aligns with the minimum and maximum loading range of the selected outdoor unit. It is not mandatory to utilize all circuits on an outdoor unit; some circuits may remain sealed without an attached indoor unit.
Warranty
- 7 year compressor limited warranty
- 5 year parts limited warranty (must be installed by a licensed HVAC technician)
- 1 year remote control
Technical Information
Model Number: CH-RSH18MFC
| Panel Model Numbers | CH-RSH18MFC | ||
| Power Supply | Rated | V,Ph,Hz | 208/230,1.60 |
|
Rated Capacity
|
Cooling | Btu/h | 17,000 |
| Heating | Btu/h | 19,000 | |
| Minimum Circuit Ampacity (MCA) | A | 1.9 | |
| Max. Fuse | A | 15 | |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) | CFM | 576.8/547.4/485.64 420.8/NA | |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) | dB(A) | 45/42.5/39.5/30.5/29 | |
|
Indoor
|
Dimension (WxDxH) | inch | 42.05x26.57x9.25 |
| Packing (WxDxH) | inch | 45.08x29.72x12.52 | |
| Net/Gross Weight | lbs. | 58.42/70.55 | |
|
Room Temperature
|
Cooling | °F | 60-90 |
| Heating | °F | 32-86 | |
| Liquid Side/Gas Side | inch | 1/4"/1/2" | |
Certifications
Performance Data/Features
-
Versatile Installation: Cooper&Hunter Universal Floor/Ceiling units are engineered for both ceiling and wall installations, capable of being placed horizontally or vertically to meet diverse architectural demands.
-
Broad Capacity Range: Available in 18K, 24K, 36K, 48K, and 60K BTU/h, these systems accommodate single-zone and multi-zone applications, making them suitable for both residential and commercial spaces.
-
High Efficiency: With an impressive SEER rating of up to 25, these units offer top-tier energy efficiency, reducing operational costs and environmental impact.
-
Streamlined and Discreet Design: The units are designed to integrate seamlessly into any setting, ensuring a discreet presence that does not disrupt interior aesthetics.
-
Extreme Weather Operation: Capable of operating effectively in ambient temperatures as low as -13°F for standard units and -22°F for Hyper Units, ensuring reliable heating even in harsh conditions.
-
Flexible Control Options: Control these units via remote control or wall thermostat, providing ease of use and enhanced user comfort.
-
Adaptable and Efficient: The flexibility in installation and control, combined with high efficiency and robust operation in various conditions, makes the Universal Floor/Ceiling units a prime choice for efficient and adaptable heating and cooling solutions.