Summary
Experience the ultimate combination of performance and versatility with C&H’s Multi Zone Hyper Heat condenser series, available in 19K, 28K, 36K, 48K, and 55K BTU/h capacities. Designed to deliver reliable heating and cooling, even in extreme conditions as low as -22°F, these outdoor units boast impressive efficiency with up to 22 SEER.
Certified for superior performance, these units support up to 5 independent zones, offering a customizable solution tailored to your space. Choose from a variety of indoor model types, including Wall Mounts, Ceiling Cassettes, Universal Floor/Ceiling, Mini Floor Consoles, Slim Ducts, and Air Handler Units, to match your unique needs and aesthetic preferences.
Important
All units must be installed by a licensed HVAC professional for the warranty to be valid. Registration is required within 60 days of installation and can be completed online or by phone. This is an Outdoor Unit ONLY. Please ensure that you have made a correct selection for an indoor unit as well in our Indoor Units section. Units are pre-charged with refrigerant up to 50FT.
What's Included
- 19,000 BTU 230V Multi-Zone Outdoor High Efficiency Hyper Heat Condenser Air Conditioner (CH-HPR19M-230VO)
- Installation Manual
- User’s Manual
- Manufacturer Warranty
Zone Combinations
| 2 ZONES |
| 6K + 6K |
| 6K + 9K |
| 6K + 12K |
| 6K + 18K |
| 9K + 9K |
| 9K + 12K |
| 9K + 18K |
| 12K + 12K |
6,000 BTU Compatible Units
| Wall Mounts | SKU |
Dimensions(WxDxH) |
| Astoria (Up to 28.1 SEER2) | CH-06MASTWM-230VI | 33.66x9.09x11.69 |
| Olivia (Up to 26.4 SEER2) | CH-06MOLVWM-230VI | 28.70x7.87x11.50 |
| Olivia Midnight (Black Style, Up to 26.4 SEER2) | CH-B06MOLVWM-230VI | 28.70x7.87x11.50 |
|
Ceiling Cassettes |
SKU | Dimensions(WxDxH) |
| One-Way Cassette (Up to 24 SEER2) | СH-06MCT1W-W | 50.31x13.19x8.98 |
9,000 BTU Compatible Units
| Wall Mounts | SKU |
Dimensions(WxDxH) |
| Astoria (Up to 28.1 SEER2) | CH-09MASTWM-230VI | 33.66x9.09x11.69 |
| Olivia (Up to 26.4 SEER2) | CH-09MOLVWM-230VI | 28.70x7.87x11.50 |
| Olivia Midnight (Black Style, Up to 26.4 SEER2) | CH-B09MOLVWM-230VI | 28.70x7.87x11.50 |
| Ceiling Cassettes | SKU | Dimensions(WxDxH) |
| One-Way Cassette (Up to 24 SEER2) | СH-09MCT1W-W | 50.31x13.19x8.98 |
| Ceiling Cassette (Up To 22.7 SEER2) | CH-09MSPHCT-230VI | 22.44x22.44x10.24 |
| Other Units | SKU | Dimensions(WxDxH) |
| Slim Duct/Concealed Duct (Up To 20.2 SEER2) | CH-M09DTUI | 27.56x19.92x7.87 |
12,000 BTU Compatible Units
| Wall Mounts | SKU |
Dimensions(WxDxH) |
| Astoria (Up to 28.1 SEER2) | CH-12MASTWM-230VI | 33.66x9.09x11.69 |
| Olivia (Up to 26.4 SEER2) | CH-12MOLVWM-230VI | 31.57x7.87x11.61 |
| Olivia Midnight (Black Style, Up to 26.4 SEER2) | CH-B12MOLVWM-230VI | 31.57x7.87x11.61 |
| Ceiling Cassettes | SKU | Dimensions(WxDxH) |
| One-Way Cassette (Up to 24 SEER2) | СH-12MCT1W-W | 50.31x13.19x8.98 |
| Ceiling Cassette (Up To 22.7 SEER2) | CH-12MSPHCT-230VI | 22.44x22.44x10.24 |
| Other Units | SKU | Dimensions(WxDxH) |
| Slim Duct/Concealed Duct (Up To 20.2 SEER2) | CH-M12DTUI | 27.56x19.92x7.87 |
| Mini Floor Console (Up to 25 SEER2) | CH-12MMC-230VI | 31.26x7.87x24.45 |
Sizing and Compatability:
Combination Chart
The capacity and number of systems can vary for each outdoor unit. Consult the combination chart for potential loading configurations. Ensure the total capacity of all connected indoor units aligns with the minimum and maximum loading range of the selected outdoor unit. It is not mandatory to utilize all circuits on an outdoor unit; some circuits may remain sealed without an attached indoor unit.
Warranty
- 7 year compressor limited warranty
- 5 year parts limited warranty (must be installed by a licensed HVAC technician)
- 1 year remote control
Technical Information
Model Number: CH-HPR19M-230VO
| Specification | Details |
| System type | Multi-zone unit |
| BTU Rated | 19,000 |
| Power source |
208-230V, 1Ph, 60Hz
|
| Dehumidification value (pnt/day) | 3.57 |
| Max. pipe length (ft) | 131 |
| Refrigerant type | R410A |
| Voltage range (V) | 187-253 |
| Packing dimensions (WxDxH) |
42.91x19.69x34.84
|
| Refrigerant piping Liquid/Gas side (inch) | 2x1/4" - 2x3/8" |
| HSPF2-5 | 7.7 |
| HSPF2-4 | 9.8 |
| EER2 | 12.5 |
| Cooling capacity (Min/Max) (BTU/h) |
19,000(5,500~25,000)
|
| SEER2 | 22 |
| Unit Net/Gross weight | 138.23/149.03 |
| Unit dimensions (W*H*D) |
37.24x16.14x31.89
|
| Refrigerant precharge | up to 50 |
| Outdoor Noise Level | 61 |
| Outdoor Air Flow | 2,129.41 |
| Minimum circuit ampacity | 20 |
| Max. fuse | 25 |
| Max height difference between Indoor and Outdoor unit | 49.21 |
| Heating capacity (Min/Max) (Btu/h) |
20,000(8,100~29,600)
|
| COP | 3.4 |
| Ambient temperature - Heating (F) | -22~75 |
| Ambient temperature - Cooling (F) | 5~122 |
| Additional Refrigerant Charge 3/8 liquid line | 0.32 |
| Additional Refrigerant Charge 1/4 liquid line | 0.16 |