MRCOOL 60K Hyper Heat Central Ducted Heat Pump Condenser | R-454B – CENTRAL-60-HP-C-230B00-O
MRCOOL 60K Hyper Heat Central Ducted Heat Pump Condenser | R-454B – CENTRAL-60-HP-C-230B00-O
Summary
The 60K MRCOOL® Hyper Heat Central Ducted Condenser is built to perform exceptionally in all weather conditions, whether enduring the chill of winter or the heat of summer. This advanced Hyper Heat system leverages DC Inverter technology and variable speed capabilities to ensure reliable and efficient operation. With a SEER2 rating of up to 16 and an HSPF2-4 rating of up to 9, it offers robust heating and cooling while optimizing energy usage. The included MRCOOL® Smart thermostat makes it easy to control your home’s climate. The 60K MRCOOL® VersaPro® Central Ducted Air Handler pairs seamlessly with the 60K MRCOOL® Hyper Heat Central Ducted Condenser. Designed for versatility, the air handler supports a variety of installation options and can be paired with an optional heat kit to enhance functionality. It uses R-454B refrigerant, an eco-conscious choice that reduces environmental impact. Durability is key to the outdoor heat pump, which is constructed with painted galvanized steel for lasting strength. The air handler is designed for convenience, featuring a compact size, slide-out blower, and a self-diagnostic panel to simplify maintenance and troubleshooting. With a 10-year warranty covering the compressor, parts, and labor, you can enjoy peace of mind knowing your system is covered. The labor warranty activates automatically at installation, with no registration necessary. Upgrade your home’s heating and cooling with the reliable, efficient 60K MRCOOL® Hyper Heat Central Ducted Condenser today!
Important
R-454B refrigerant (low GWP). Variable-speed DC inverter. Side-discharge, compact footprint. Smart thermostat included. Pairs with VersaPro® Central Ducted Air Handler (matching capacity).
What's Included
- Outdoor Condenser (CENTRAL-60-HP-C-230B00-O)
- MRCOOL® Smart Thermostat
- Installation & Owner’s Manual
- Service Manual
- Warranty Information
Features
- Up to SEER2 16 / EER2 10; HSPF4 9 / HSPF5 8
- Eco-forward R-454B refrigerant
- DC inverter, variable-speed compressor for precise comfort
- Quiet operation (~65 dBA), compact side-discharge chassis
- Painted galvanized steel construction
- Self-diagnostics for easier service
- Wi-Fi/App control via included Smart Thermostat
Technical Specifications
| Brand / Series | MRCOOL / Central Ducted Hyper Heat 2nd Gen |
| Model | CENTRAL-60-HP-C-230B00-O |
| GTIN | 00840255586542 |
| UPC | 840255586542 |
| Unit Type | Split System Heat Pump |
| Equipment Type | Condenser |
| SEER2 | 16 |
| EER2 | 10 |
| HSPF-4 | 9 |
| HSPF-5 | 8 |
| CFM (Outdoor Airflow) | 2648.6 |
| Tonnage | 5 |
| Cooling Capacity (BTU) | 54,000 |
| Heating Capacity (BTU) | 56,000 |
| Voltage / Phase / Cycle | 208–230 V / 1-Phase / 60 Hz |
| Max Fuse / Breaker (A) | 40 |
| Min Circuit Ampacity (A) | 40 |
| Color | Gray |
| Refrigerant | R-454B |
| Factory Charge (oz) | 183.42 |
| Decibel Rating (dBA) | ~65 |
| Liquid / Suction Line Sizes | 3/8" / 3/4" |
| Wi-Fi / App Compatibility | Yes / Yes (Smart Thermostat included) |
| Certifications | ETL Certified; AHRI Certified; ENERGY STAR®: Yes |
| Net Dimensions (W × D × H) | 37.48" × 16.34" × 52.48" |
| Net / Gross Weight | 242.95 lbs / 275.13 lbs |
| Gross Dimensions (W × D × H) | 43.11" × 19.49" × 58.27" |
| Contains Electronics / Chemicals / Compressed Gas | Yes / Yes / Yes |
Airflow, Refrigerant & Installation Limits
| Outdoor Airflow | 2648.6 CFM |
| Line Set Sizes | Liquid 3/8" • Suction 3/4" |
| Line Length & Elevation | See Installation/Service Manual for rated & max lengths and elevation limits. |
| Additional Refrigerant | See manual for charge adjustment per added line length. |
Compatibility & Pairing
| Works With | VersaPro® Central Ducted Air Handler (matching capacity) |
Warranty Information
- Base Parts Warranty: 10 Years (limited)
- Base Compressor Warranty: 10 Years (limited)
- Base Labor Warranty: 10 Years (limited; automatically activated at installation)
Manuals & Downloads
Safety & Install Notes
- Install on a solid, level base; follow clearances and anchoring guidance.
- Dedicated 208/230V, 1-phase circuit; include proper disconnect and follow wiring/torque specifications.
- Use specified line sizes; evacuate, leak-check, and charge per R-454B (A2L) procedures.
- Provide adequate ventilation; avoid flammables and corrosive atmospheres near the unit.
- Comply with national/local codes; installation and service by qualified personnel only.
Environmental & Efficiency Features
Low-GWP R-454B and inverter technology deliver efficient, cold-climate performance with reduced environmental impact and steady comfort.