MRCOOL
SKU:
MCAESHS4T2421AA

Additional Information

AC Type:
Air Handler
Refrigerant Type:
R-454B
Indoor Unit:
2 Ton (24K Class)
Voltage:
208/230
SEER2 Rating:
14.3 SEER2 • 7.5 HSPF2
HSPF2:
7.5
EER2:
11.7
Tonnage:
2
Cooling Capacity (BTU):
22000
Heating Capacity (BTU):
22000
CFM:
1950
Decibel (dBA):
60
Inverter:
No
Energy Star:
No
Max Lineset (ft):
100
Min Ambient Cool (°F):
59
Min Ambient Heat (°F):
5
Net Weight (lbs):
144
Brand:
MRCOOL
Volt:
230V
SEER:
14.3
WIFI:
Included
Zone:
Single Zone
Type:
Air Handler
BTU:
22,000 BTU
Freon Type:
R-454B
New
$2,741.22
Adding to cart… The item has been added

MRCOOL — Signature Series Split System (Multi-Position Air Handler + Heat Pump Condenser)

MRCOOL® Signature Series 24K (2 Ton) Heat Pump System — MCAEAMPSF24C21AA + MCAESHS4T2421AA

Overview

24K Class 2 Ton Heat Pump 14.3 SEER2 11.7 EER2 7.5 HSPF2 R-454B Multi-Position Air Handler Upflow / Downflow / Horizontal AHRI Certified 10-Year Parts Warranty

The MRCOOL® Signature Series 24K heat pump system pairs a multi-position air handler with a split-system heat pump condenser for year-round heating and cooling. The air handler supports upflow, downflow, and horizontal installations for flexible placement, and both components use R-454B refrigerant.

Highlights

  • Year-round comfort: Heat pump provides heating + cooling from one outdoor unit.
  • Efficient ratings: Outdoor unit listed at 14.3 SEER2, 11.7 EER2, and 7.5 HSPF2.
  • Flexible install: Air handler supports upflow, downflow, and horizontal configurations.
  • Modern refrigerant: System uses R-454B.
  • Cold-weather note: Outdoor unit lists 5°F minimum ambient heating operation.
System Size
2 Ton (24K Class)
Efficiency
14.3 SEER2 • 7.5 HSPF2
Line Sizes
3/8" Liquid • 3/4" Suction
Min Ambient
59°F Cool • 5°F Heat

Performance varies by climate and installation. Manual J sizing is recommended.

What’s Included

  • Multi-Position Air Handler: MCAEAMPSF24C21AA
  • Heat Pump Condenser: MCAESHS4T2421AA
  • Documentation (see Documents & Downloads)

Indoor Specs

Model: MCAEAMPSF24C21AA (Signature Series Multi-Position Air Handler)

Unit Type Air Handler
Configuration / Mount Multi-Position (Upflow / Downflow / Horizontal)
Tonnage 2 Ton
Airflow (CFM) 761
Sound 53 dB(A)
Refrigerant R-454B
Metering Device Orifice
Drain Connection Size 3/4"
Line Sizes Liquid 3/8" • Suction 3/4"
Blower Motor Type PSC
Blower Motor 1/3 HP • 3 Speeds • 910 RPM
Filter Replaceable • 18" × 21" × 1"
Electrical 208/230V • 1-Phase • 60 Hz
Min Circuit Ampacity (MCA) 2.4A
Max Fuse / Breaker 3A
Aux Heat Not included • Optional heat kit available (5 kW, 7.5 kW, 10 kW)
Certifications UL Listed • CSA Listed • ETL Listed • AHRI Certified
Color Grey
Dimensions (W×D×H) 19.625" × 22" × 45.75"
Net Weight 128 lb
GTIN / UPC GTIN 00840255595858 • UPC 840255595858
Proposition 65 Yes

Designed to work with Signature Series top discharge condensers.

Outdoor Specs

Model: MCAESHS4T2421AA (Signature Series Split System Heat Pump Condenser)

Unit Type Split System Heat Pump Condenser
Tonnage 2 Ton
Cooling / Heating Capacity 22,000 BTU / 22,000 BTU
Efficiency 14.3 SEER2 • 11.7 EER2 • 7.5 HSPF2
Airflow (CFM) 1950
Sound 60 dB(A)
Inverter No
Min Ambient (Cooling) 59°F
Min Ambient (Heating) 5°F
Refrigerant R-454B • 91.7 oz
Max Line Set Length 100 ft
Line Sizes Liquid 3/8" • Suction 3/4"
Compressor Scroll
Condenser Fan Motor PSC • 1/9 HP
Electrical 208/230V • 1-Phase • 60 Hz
Min Circuit Ampacity (MCA) 15.2A
Max Fuse / Breaker 20A
Certifications UL Listed • CSA Listed • ETL Listed • AHRI Certified
Color Grey
Dimensions (W×D×H) 23.6" × 23.6" × 25"
Net Weight 144 lb
GTIN / UPC GTIN 00840255595780 • UPC 840255595780
Proposition 65 Yes

Designed to work with Signature Series Multi-Position or Stud Mount air handlers.

Documents & Downloads

  • Signature Series Multi-Position Air Handler (MCAEAMPSF24C21AA)
  • Signature Series Heat Pump Condenser (MCAESHS4T2421AA)

Important

  • Heat pump operation: This pairing includes a heat pump condenser for heating + cooling.
  • Minimum outdoor temps: Outdoor unit lists 59°F minimum ambient for cooling and 5°F minimum ambient for heating.
  • Line sizes: Listed as 3/8" liquid and 3/4" suction; confirm routing and any long-line requirements in the installation manual.
  • Line set length: Outdoor unit lists up to 100 ft maximum line set length; verify long-line accessories/requirements in the install manual.
  • Electrical: Both components are 208/230V, 1-phase, 60 Hz. Verify breaker/fuse sizing per install manual and local code.
  • Aux heat option: Air handler supports optional heat kits (listed as 5 kW, 7.5 kW, and 10 kW) for added cold-weather comfort (sold separately).

FAQs

Does this system provide heating and cooling?

Yes. The outdoor unit is a heat pump condenser, so the system is listed for both heating and cooling.


What installation positions does the air handler support?

The air handler is multi-position and supports upflow, downflow, and horizontal configurations.


What refrigerant and line sizes does it use?

Refrigerant is listed as R-454B. Line sizes are 3/8" liquid and 3/4" suction.


How cold can it run in heating?

The outdoor unit lists a minimum ambient heating temperature of 5°F.


What warranty coverage is included?

Warranty is listed as 10-year limited parts, with limited lifetime compressor coverage referenced for the outdoor unit.