Cooper & Hunter 48,000 BTU 3-Zone 18k+18k+24k Universal Floor/Ceiling, 230V, R454B - Ductless Mini Split Air Conditioner Heat Pump

Cooper & Hunter7-Yr WarrantySKU: CH-R48MES-230VO18FC24FC
Product specifications
- Voltage
- 230V
- Type
- Universal Floor/Ceiling
- Freon
R454B
Choose Your Configuration
Save 10% on these accessories
ARMBRIDGE Mini Split Wall Mounting Bracket High Load Capacity Zinc, Vibration-Absorbing (Up to 550 lbs Each)-10%$49.00
ARMBRIDGE Heavy-Duty Mini Split Ground Stand, Zinc-Coated Brackets for 24,000–60,000 BTU Units Weatherproof Design, 330+ lbs Capacity-10%$89.00
ARMBRIDGE 30 AMP Fusible Metallic Disconnect Box Durable Enclosed Disconnect for Residential and Light Commercial HVAC Systems-10%$29.00
ARMBRIDGE Non-Metallic A/C Whip 3/4" x 6 ft – Pre-Wired Liquid tight Conduit with 8/2 & 10/1 Wires for HVAC & Air Conditioner Power Connection-10%$34.00
FREE Delivery
Ships from the nearest of our three US warehouses, leaves in 1–2 business days. Shipping policy
COOPER & HUNTER · UNIVERSAL FLOOR/CEILING
Built for year-round comfort

CH-R48MES-230VO18FC24FC
Product Description
With its high efficiency and high SEER compressor, this newest model Cooper & Hunter ductless mini split will both heat and cool your home or office. The DC inverter heat pump pulls heat from the air down to temperatures as low as -13°F! You are well protected by a seven year warranty on the compressor, a five year parts warranty (must be installed by a licensed HVAC technician), abundant parts availability and smart, experienced technicians should you ever need assistance. This model features a safe and rugged Toshiba-GMCC inverter compressor. CAPACITY
6 Modes for Maximum Comfort
Engineered to adapt to every season, every room, every need.
Maintain a comfortable indoor temperature by automatically switching between heating and cooling as needed. Ideal for year-round use.
WHEREVER YOU ARE
Control your comfort, your way
- Easy scheduling & timer
- Multiple ways to control your comfort
- Smart geo location
- In-app support & assistance
- Voice control

WARRANTY
BACKED BY COOPER & HUNTER
Industry-leading protection on every unit
Compressor: 7-year coverage
With product registration after professional installation.
Parts & components: 5-year coverage
All major components and refrigerant circuit parts.
Technical Specifications
Series Comparison Table
Technical specifications for every model in the series — this product is one of them.
Indoor Model
| Specification | CH-18MSPHFC-230VI | CH-24MSPHFC-230VI | CH-36LCFC/I | CH-48LCFC/I | CH-60LCFC-W |
|---|---|---|---|---|---|
| Power Supply Rated (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity Cooling (Btu/h) | 18,000 | 24,000 | 36,000 | 48,000 | 54,000 |
| Rated Capacity Heating (Btu/h) | 20,000 | 24,000 | 38,000 | 50,000 | 60,000 |
| Minimum Circuit Ampacity (MCA) (A) | 1.9 | 2.5 | 1.9 | 2.3 | 3 |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) | 583/548/485/421 | 795/759/708/598 | 1,075/1,036/917/638 | 1,400/1,353/1,118/1,000 | 1,430/1,384/1,029/795 |
| Indoor Noise Level (Hi/Mi/Lo) (dB(A)) | 47/43.5/40.5 | 51/47/42 | 51.5/48.0/40.5 | 55/49.5/44.5 | 55/48/42 |
| Indoor Dimension (WxDxH) (inch) | 42.05x26.57x9.25 | 42.05x26.57x9.25 | 50.59x26.57x9.25 | 64.96x26.57x9.25 | 64.96x26.57x9.25 |
| Indoor Packing (WxDxH) (inch) | 45.08x29.72x12.52 | 45.08x29.72x12.52 | 53.54x29.72x12.52 | 67.91x29.72x12.52 | 67.91x29.72x12.52 |
| Indoor Net/Gross Weight (lbs.) | 57.10/68.34 | 60.63/72.09 | 69/81.57 | 87.74/102.29 | 96.56/111.99 |
| Room Temperature Cooling (°F) | 62~90 | 62~90 | 62~90 | 62~90 | 62~90 |
| Room Temperature Heating (°F) | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 |
| Liquid Side/Gas Side (inch) | 1/4"/1/2" | 3/8"/5/8" | 3/8"/5/8" | 3/8"/5/8" | 3/8"/7/8" |
Outdoor Models Regular
| Specification | CH-R48MES-230VOThis model | CH-R18MES-230VO | CH-R28MES-230VO | CH-R36MES-230VO | CH-R60MES-230VO |
|---|---|---|---|---|---|
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Rated Capacity (range) (Btu/h) | 12,000~55,000 | 5,400~21,600 | 7,200~32,000 | 9,000~42,000 | 19,000~62,000 |
| Cooling Rated Current (A) | 16.6 | 6 | 9.2 | 13.5 | 26.2 |
| EER2 | 12.5 | 14 | 13 | 12 | 10 |
| SEER2 | 24 | 25.1 | 25 | 24 | 22 |
| Heating Rated Capacity (range) (Btu/h) | 13,000~53,000 | 5,700~21,600 | 8,400~29,000 | 10,000~42,500 | 20,000~60,000 |
| Heating Rated Current (A) | 16.3 | 6.8 | 9.2 | 14 | 21 |
| Heating at 47°F COP (W/W) | 3.8 | 3.8 | 3.8 | 3.5 | 3.7 |
| HSPF4 | 10.3 | 9.8 | 9.5 | 9.5 | 9.5 |
| HSPF5 | 8 | 7.8 | 7 | 7 | 7.4 |
| Heating at 5°F Rated Capacity (Btu/h) | 36,000 | 13,500 | 19,000 | 26,000 | 39,000 |
| Minimum Circuit Ampacity (Outdoor unit) (A) | 40 | 16 | 23 | 30.5 | 40 |
| Max. Fuse (Outdoor unit) (A) | 45 | 20 | 25 | 35 | 45 |
| Outdoor Air Flow (Max) (CFM) | 4,502.8 | 1,765.8 | 2,130.7 | 2,148.4 | 4,502.8 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 63 | 59.5 | 61 | 64.5 | 65 |
| Dimension (W×D×H) (inch) | 37.48x16.34x52.48 | 35.04x13.46x26.50 | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 |
| Packing (W×D×H) (inch) | 43.11x19.49x58.27 | 40.55x17.24x29.53 | 42.91x19.68x34.84 | 42.91x19.68x34.84 | 43.11x19.49x58.27 |
| Net/Gross Weight (lbs) | 222.00/254.19 | 100.53/109.35 | 138.89/149.69 | 168.87/180.12 | 237.88/270.28 |
| Refrigerant Type/Charged (oz) | R454B/148.15 | R454B/61.73 | R454B/84.66 | R454B/120.63 | R454B/151.68 |
| Refrigerant Precharge (ft) | 150 | 75 | 100 | 125 | 150 |
| Additional Charge for Each (0.16 for 1/4 in liquid pipe / *0.32 for 3/8 in liquid pipe) (oz/ft) | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side (inch) | 6 x 1/4" | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 6 x 1/4" |
| Refrigerant Piping Gas Side (inch) | 4 x 3/8" + 2 x 1/2" | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 4 x 3/8" + 1 x 1/2" | 4 x 3/8" + 2 x 1/2" |
| Max. Pipe Length (ft) | 262.4 | 196.8 | 262.4 | 262.4 | 262.4 |
| Max. Length for One Indoor Unit (ft) | 114.8 | 98.4 | 114.8 | 114.8 | 114.8 |
| Max. Height Difference in Level (ft) | 49.2 | 49.2 | 49.2 | 49.2 | 49.2 |
| Max. Height Difference Between Indoor Units (ft) | 33 | 33 | 33 | 33 | 33 |
| Ambient Temperature Cooling (°F) | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 |
| Ambient Temperature Heating (°F) | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 |
| Certification: AHRI | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: Energy Star | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: NEEP | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: ETL | ✔ | ✔ | ✔ | ✔ | ✔ |
Indoor Models Hyper
| Specification | CH-18MSPHFC-230VI | CH-24MSPHFC-230VI | CH-36LCFC/I | CH-48LCFC/I | CH-60LCFC-W |
|---|---|---|---|---|---|
| Power Supply Rated (V, Ph, Hz) | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 |
| Rated Capacity Cooling (Btu/h) | 17,000 | 24,000 | 36,000 | 48,000 | 55,000 |
| Rated Capacity Heating (Btu/h) | 18,000 | 25,000 | 39,000 | 51,000 | 60,000 |
| Minimum Circuit Ampacity (MCA) (A) | 1.9 | 2.5 | 1.9 | 2.3 | 3 |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) | 583/548/485/421 | 795/759/708/598 | 1,075/1,036/917/638 | 1,400/1,353/ 1,118/1,000 | 1,430/1,384/1,029/795 |
| Indoor Noise Level (Hi/Mi/Lo) (dB(A)) | 45.5/43/39 | 51/47.5/42 | 52.5/48.5/42.5 | 55/50/44 | 54/47/44 |
| Indoor Dimension (WxDxH) (inch) | 42.05x26.57x9.25 | 42.05x26.57x9.25 | 50.59x26.57x9.25 | 64.96x26.57x9.25 | 64.96x26.57x9.25 |
| 45.08×29.72x12.52 | 45.08x29.72x12.52 | 53.54x29.72x12.52 | 67.91x29.72x12.52 | 67.91x29.72x12.52 | |
| Indoor Net/Gross Weight (lbs.) | 57.10/68.34 | 60.63/72.09 | 69/81.57 | 87.74/102.29 | 96.56/111.99 |
| Room Temperature (°F) | Cooling: 62~90 | Cooling: 62~90 | Cooling: 62~90 | Cooling: 62 ~ 90 | Cooling: 62~ 90 |
| Heating: 32~86 | Heating: 32~86 | Heating: 32~86 | Heating: 32~86 | Heating: 32~86 | |
| Liquid Side/Gas Side (inch) | 1/4"/1/2" | 3/8"/5/8" | 3/8"/5/8" | 3/8"/5/8" | 3/8"/7/8" |
Outdoor Models Hyper
| Specification | CH-RVHP19M-230VO | CH-RVHP28M-230VO | CH-RVHP36M-230VO | CH-RVHP48M-230VO | CH-RVHP55M-230VO |
|---|---|---|---|---|---|
| Power Supply (V/Ph/Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Operating Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Capacity (BTU/h) | 5,400~28,000 | 7,200~37,000 | 9,000~43,000 | 12,000~57,000 | 19,000~59,000 |
| SEER2 | 5.6 | 9.5 | 12 | 17.3 | 18.5 |
| EER | 15 | 12.5 | 13 | 12 | 12 |
| IEER | 25 | 23 | 23 | 23 | 22.2 |
| Heating Capacity (BTU/h) | 5,700~27,000 | 8,400~36,000 | 10,000~44,000 | 13,000~57,000 | 20,000~59,000 |
| HSPF2 | 6.5 | 9.1 | 11.5 | 17.3 | 20.1 |
| COP | 4 | 3.8 | 4 | 3.7 | 3.5 |
| SCOP | 10.4 | 10.5 | 10.7 | 11 | 10.5 |
| Power Input (W) | 8.5 | 8.5 | 8.5 | 9 | 8.5 |
| Air Flow (CFM) | 19,000 | 27,000 | 36,000 | 47,000 | 47,000 |
| Sound Level Indoor (dBA) | 17.5 | 30 | 37 | 37 | 39.5 |
| Sound Level Outdoor (dBA) | 20 | 35 | 40 | 40 | 40 |
| Weight Indoor (lbs) | 2,130.7 | 2,148.4 | 3,037.2 | 4,502.8 | 4,502.8 |
| Weight Outdoor (lbs) | 61.5 | 61 | 65 | 65 | 65 |
| Dimensions Indoor (in) | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 38.58x16.34x38.39 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Dimensions Outdoor (in) | 42.91x19.68x34.84 | 42.91x19.68x34.84 | 45.08x19.68x42.52 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Shipping Weight Indoor/Outdoor (lbs) | 137.35/148.15 | 168.43/179.67 | 211.86/244.71 | 246.47/276.68 | 246.47/276.68 |
| Refrigerant Type/Amount (lbs) | R454B/78.31 | R454B/120.63 | R454B/134.04 | R454B/151.68 | R454B/151.68 |
| Fuse Size (A) | 75 | 100 | 125 | 150 | 150 |
| Wire Size (AWG) | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 |
| Control Voltage (V) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Liquid Line | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 6 x 1/4" | 6 x 1/4" |
| Suction Line | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 3 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" |
| Max Line Length (ft) | 196.8 | 262.4 | 262.4 | 262.4 | 262.4 |
| Max Elevation Diff (ft) | 98.4 | 114.8 | 114.8 | 114.8 | 114.8 |
| Max Head Pressure (ft) | 49.2 | 49.2 | 49.2 | 49.2 | 49.2 |
| Max Suction Pressure (ft) | 33 | 33 | 33 | 33 | 33 |
| Operating Range Cooling (°F) | -22~122 | -22~122 | -22~122 | -22~122 | -22~122 |
| Operating Range Heating (°F) | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 |
| Feature 1 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 2 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 3 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 4 | ✓ | ✓ | ✓ | ✓ | ✓ |
Manufacturer Technical Support
Reach your brand's tech support team directly
You may also like
- R32SEER2 22.0Heats & Cools
7-Yr Warranty
Bravo2 zone 18,000 BTU BRAVO Non-Ducted Mini Split AC Universal Floor & Ceiling Console 9k+9KFree Shipping
- R32SEER2 22.0Heats & Cools
7-Yr Warranty
Bravo2 zone 18,000 BTU BRAVO Non-Ducted Mini Split AC Universal Floor & Ceiling Console 9k+12KFree Shipping
- R32SEER2 22.0Heats & Cools
7-Yr Warranty
Bravo2 zone 18,000 BTU BRAVO Non-Ducted Mini Split AC Universal Floor & Ceiling Console 12k+12KFree Shipping
- R454BSEER2 23.3HEATS down to −13°FCOOLS up to 122°F
7-Yr Warranty
Cooper & HunterCooper & Hunter 18,000 BTU Single Zone Universal Floor/Ceiling, 230V, R454B - Ductless Mini Split Air Conditioner Heat PumpFree Shipping
* ALL OF OUR MULTI ZONE SYSTEMS COME PRE-BUNDLED WITH A 25FT INSTALLATION KIT FOR EACH ZONE. WE CARRY 16FT, 25FT, AND 50FT. TO CUSTOMIZE, SEND US A MESSAGE OR GIVE US A CALL!
|
CAPACITY |
POWER |
EFFICIENCY |
|
48,000 BTU |
230V |
24 SEER |
- High Density Filter
- Inverter Technology
- Turbo Function
- Silent Function
- Auto Swing Louvers
- Follow Me Function
- Comfortable Sleep Mode
- Multiple Fan Speed Options
- Drain Connection
- Refrigerant Leakage Detection
- Timer
INCLUDED IN YOUR ORDER:
Cooper & Hunter Multi Zone Ductless Mini Split System 48,000 BTU Inverter with Heat Pump
* OUTDOOR UNIT 48,000 BTU (1pc)
* INDOOR UNIT 18,000 BTU (2pcs) + 24,000 BTU (1pc) with remotes
Cooper&Hunter Limited Warranty terms are available if the product is registered within 60 days of installation. THE UNIT(S) MUST BE INSTALLED BY A LICENSED HVAC PROFESSIONAL FOR VALID WARRANTY. Registration can be completed online or by phone.