Cooper & Hunter 6 Zone 48,000 BTU Concealed Duct Mini Split AC R454B 6K+9K+9K+9K+9K+12K
Cooper & Hunter7-Yr WarrantySKU: CH-R48MES-230VO/M06DT+M09DT+M09DT+M09DT+M09DT+M12DT-NO
Product specifications
- Voltage
- 230V
- SEER
- 22.0
- WiFi
- Included
- Zone
- Six Zone
- Type
- Concealed Duct
- Freon
R454B
Choose Your Configuration
Save 10% on these accessories
ARMBRIDGE Mini Split Wall Mounting Bracket High Load Capacity Zinc, Vibration-Absorbing (Up to 550 lbs Each)-10%$49.00
ARMBRIDGE Heavy-Duty Mini Split Ground Stand, Zinc-Coated Brackets for 24,000–60,000 BTU Units Weatherproof Design, 330+ lbs Capacity-10%$89.00
ARMBRIDGE 30 AMP Fusible Metallic Disconnect Box Durable Enclosed Disconnect for Residential and Light Commercial HVAC Systems-10%$29.00
ARMBRIDGE Non-Metallic A/C Whip 3/4" x 6 ft – Pre-Wired Liquid tight Conduit with 8/2 & 10/1 Wires for HVAC & Air Conditioner Power Connection-10%$34.00
FREE Delivery
Ships from the nearest of our three US warehouses, leaves in 1–2 business days. Shipping policy
COOPER & HUNTER · CONCEALED DUCT
Built for year-round comfort
CH-R48MES-230VO/M06DT+M09DT+M09DT+M09DT+M09DT+M12DT-NO
System Specs
| Cooling Capacity | 47,000 BTU/h |
|---|---|
| Heating Capacity | 48,000 BTU/h |
| SEER2 | 24 |
| EER2 | 12.5 |
| Voltage | 230V |
| Refrigerant | R454B |
|---|---|
| Compressor | Inverter |
| Climate Range | -13–122°F / -13–75°F outdoor ambient |
| Sound Level (indoor) | 36/34.5/32.5 dB |
| Warranty | 7-Yr Compressor |
Indoor Unit Specs
| Unit Dimensions (WxDxH) | Net / Gross Weight | Remote Control |
|---|---|---|
| 27.56 × 19.92 × 7.87 in | 39.46 / 46.74 lb | Wire controller + remote controller available |
Product Description
The Cooper & Hunter 6-Zone Mini Split System features a 48,000 BTU capacity, 24 SEER2 efficiency, and built-in Wi-Fi control for seamless temperature management across six zones. It utilizes R454B refrigerant and operates effectively in heating conditions as low as -13°F, ensuring reliable performance in colder climates.
6 Modes for Maximum Comfort
Engineered to adapt to every season, every room, every need.
Maintain a comfortable indoor temperature by automatically switching between heating and cooling as needed. Ideal for year-round use.
WHEREVER YOU ARE
Control your comfort, your way
- Easy scheduling & timer
- Multiple ways to control your comfort
- Smart geo location
- In-app support & assistance
- Voice control

IN THE BOX
Everything included with this system
- Cooper & Hunter MES 48,000 BTU Outdoor Condenser, 230V, R454B - Mini Split Air Conditioner Heat Pump
- Indoor Concealed Duct — CH-RS06-12MDT- MS × 6
WARRANTY
BACKED BY COOPER & HUNTER
Industry-leading protection on every unit
Compressor: 7-year coverage
With product registration after professional installation.
Parts & components: 5-year coverage
All major components and refrigerant circuit parts.
Technical Specifications
Outdoor Unit Specs— CH-R48MES-230VO
| Model | CH-R48MES-230VO |
|---|---|
| Unit Dimensions (WxDxH) | 37.48 x 16.34 x 52.48 in |
| Net/Gross Weight | 222.00/254.19 lb |
| Packing Dimensions (WxDxH) | 43.11 x 19.49 x 58.27 in |
| Power Supply | 208-230V, 1Ph, 60Hz |
| Maximum Fuse Size | 40 A |
| Min. Circuit Ampacity | 34 A |
| Copper Line Size (Liquid/Gas) | 6x1/4" - 4x3/8"+2x1/2" |
| Noise Level | 63 dB |
| Airflow | 4,502.8 CFM |
| Dehumidification | 6.98 pt/h |
Indoor Unit Specs— CH-RS06-12MDT- MS
| Model | CH-RS06-12MDT- MS |
|---|---|
| Unit Dimensions (WxDxH) | 27.56 x 19.92 x 7.87 in |
| Net/Gross Weight | 39.46/46.74 lb |
| Packing Dimensions (WxDxH) | 33.86 x 21.26 x 11.22 in |
| Power Supply | 208-230V, 1Ph, 60Hz |
| Maximum Fuse Size | 15 A |
| Min. Circuit Ampacity | 3 A |
| Copper Line Size (Liquid/Gas) | 1/4"/3/8" |
| Noise Level (Hi/Med/Lo) | 36/34.5/32.5 dB |
| Dehumidification | 2.66 pt/h |
| Filter Dimensions | 23.3x7.24 in |
| Drain Pipe Diameter | 1" |
| Controller | wire controller + remote controller available |
System Specs
| Cooling — Rated Capacity (Range) | 47,000 Btu/h (12,000–55,000) |
|---|---|
| Heating at 47°F — Rated Capacity (Range) | 48,000 Btu/h (13,000–53,000) |
| Rated Heating at 5°F | 36,000 Btu/h |
| SEER2 / EER2 | 24 / 12.5 |
| HSPF4 / HSPF5 / COP (47°F) | 10.3 / 8 / 3.8 |
| Outdoor Unit MCA / Max. Fuse | 34 A / 40 A |
| Max. Connectable Indoor Units | 6 |
| Outdoor Noise Level | 63 dB(A) |
| Outdoor Unit Dimensions (W×D×H) | 37.48 × 16.34 × 52.48 in |
| Outdoor Unit Net / Gross Weight | 222.00 / 254.19 lbs |
| Refrigerant Type / Charge | R454B / 148.15 oz |
| Pre-charged Line Length | 150 ft (add 0.16 oz/ft for 1/4 in liquid pipe / 0.32 oz/ft for 3/8 in liquid pipe) |
| Max. Total Pipe Length / Max. to One Indoor | 262.4 ft / 114.8 ft |
| Max. Height Difference (Indoor–Outdoor / Between Indoors) | 49.2 ft / 33 ft |
| Operating Range — Cooling / Heating | -13–122°F / -13–75°F outdoor ambient |
Series Comparison Table
Technical specifications for every model in the series — this product is one of them.
Indoor
| Specification | CH-RS06MDT-MSCH-RS06-12MDT-MS (Dip Switch 6) | CH-RS09MDT-MSCH-RS06-12MDT-MS (Dip Switch 9) | CH-RS12MDT-MSCH-RS06-12MDT-MS (Dip Switch 12) | CH-RS18MDT-MS | CH-RS24MDT-HS | CH-RS36LCDT-HS | CH-RS48LCDT-HS | CH-RS60LCDT-HS |
|---|---|---|---|---|---|---|---|---|
| Power Supply | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 | 208/230,1, 60 |
| Rated Capacity | 6,500/8,000 | 9,000/10,000 | 12,000/12,500 | 17,000/19,000 | 24,000/26,000 | 36,000/42,000 | 48,000/52,000 | 55,000/60,000 |
| Minimum Circuit Ampacity (MCA) | 3 | 3 | 3 | 3 | 3 | 4 | 5 | 5 |
| Max. Fuse | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) CFM | 323.7/264.9/206.0/147.2/117.7 | 323.7/264.9/206.0/147.2/117.7 | 400.2/323.7/264.9/176.6/117.7 | 600.4/559.2/500.3/441.4/NA | 853.5/706.3/618.0/500.3/NA | 1236.1/1059.5/941.8/766.5/NA | 1648.1/1471.5/1294.9/1059.5/NA | 2001.2/1706.9/1412.6/1118.3/NA |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) dB(A) | NA/32.5/30.5/29.5/22 | NA/32.5/31/29.5/23 | NA/36/34.5/32.5/25.5 | NA/40/39/38/32 | NA/40/37/35/29.5 | NA/45/40/34/31 | NA/51/46/42/40 | NA/52/48/42/41 |
| Dimension (WxDxH) inch | 27.56 x 19.92 x 7.87 | 27.56 x 19.92 x 7.87 | 27.56 x 19.92 x 7.87 | 34.65 x 26.54 x 8.27 | 39.37 x 29.53 x 9.65 | 47.24 x 29.53 x 11.81 | 47.24 x 29.53 x 11.81 | 55.12 x 31.50 x 14.96 |
| Packing (WxDxH) inch | 33.86 x 21.26 x 11.22 | 33.86 x 21.26 x 11.22 | 33.86 x 21.26 x 11.22 | 42.13 x 28.54 x 11.02 | 48.23 x 33.86 x 11.97 | 56.10 x 33.86 x 14.13 | 56.10 x 33.86 x 14.13 | 62.99 x 36.02 x 17.52 |
| Net/Gross Weight lbs. | 39.46/46.74 | 39.46/46.74 | 39.46/46.74 | 54.45/66.14 | 80.47/91.93 | 106.26/120.37 | 111.33/124.78 | 161.38/178.13 |
| Room Temperature Cooling °F | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 |
| Room Temperature Heating °F | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 |
| Liquid Side/Gas Side inch | 1/4"/3/8" | 1/4"/3/8" | 1/4"/3/8" | 1/4"/1/2" | 3/8"/5/8" | 3/8"/3/4" | 3/8"/3/4" | 3/8"/3/4" |
Outdoor Regular
| Specification | CH-R48MES-230VOThis model | CH-R18MES-230VO | CH-R28MES-230VO | CH-R36MES-230VO | CH-R60MES-230VO |
|---|---|---|---|---|---|
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Rated Capacity (range) (Btu/h) | 12,000~55,000 | 5,400~21,600 | 7,200~32,000 | 9,000~42,000 | 19,000~62,000 |
| Cooling Rated Current (A) | 16.6 | 6 | 9.2 | 13.5 | 26.2 |
| EER2 | 12.5 | 14 | 13 | 12 | 10 |
| SEER2 | 24 | 25.1 | 25 | 24 | 22 |
| Heating Rated Capacity (range) (Btu/h) | 13,000~53,000 | 5,700~21,600 | 8,400~29,000 | 10,000~42,500 | 20,000~60,000 |
| Heating Rated Current (A) | 16.3 | 6.8 | 9.2 | 14 | 21 |
| Heating at 47°F COP (W/W) | 3.8 | 3.8 | 3.8 | 3.5 | 3.7 |
| HSPF4 | 10.3 | 9.8 | 9.5 | 9.5 | 9.5 |
| HSPF5 | 8 | 7.8 | 7 | 7 | 7.4 |
| Heating at 5°F Rated Capacity (Btu/h) | 36,000 | 13,500 | 19,000 | 26,000 | 39,000 |
| Minimum Circuit Ampacity (Outdoor unit) (A) | 40 | 16 | 23 | 30.5 | 40 |
| Max. Fuse (Outdoor unit) (A) | 45 | 20 | 25 | 35 | 45 |
| Outdoor Air Flow (Max) (CFM) | 4,502.8 | 1,765.8 | 2,130.7 | 2,148.4 | 4,502.8 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 63 | 59.5 | 61 | 64.5 | 65 |
| Dimension (W×D×H) (inch) | 37.48x16.34x52.48 | 35.04x13.46x26.50 | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 |
| Packing (W×D×H) (inch) | 43.11x19.49x58.27 | 40.55x17.24x29.53 | 42.91x19.68x34.84 | 42.91x19.68x34.84 | 43.11x19.49x58.27 |
| Net/Gross Weight (lbs) | 222.00/254.19 | 100.53/109.35 | 138.89/149.69 | 168.87/180.12 | 237.88/270.28 |
| Refrigerant Type/Charged (oz) | R454B/148.15 | R454B/61.73 | R454B/84.66 | R454B/120.63 | R454B/151.68 |
| Refrigerant Precharge (ft) | 150 | 75 | 100 | 125 | 150 |
| Additional Charge for Each (0.16 for 1/4 in liquid pipe / *0.32 for 3/8 in liquid pipe) (oz/ft) | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side (inch) | 6 x 1/4" | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 6 x 1/4" |
| Refrigerant Piping Gas Side (inch) | 4 x 3/8" + 2 x 1/2" | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 4 x 3/8" + 1 x 1/2" | 4 x 3/8" + 2 x 1/2" |
| Max. Pipe Length (ft) | 262.4 | 196.8 | 262.4 | 262.4 | 262.4 |
| Max. Length for One Indoor Unit (ft) | 114.8 | 98.4 | 114.8 | 114.8 | 114.8 |
| Max. Height Difference in Level (ft) | 49.2 | 49.2 | 49.2 | 49.2 | 49.2 |
| Max. Height Difference Between Indoor Units (ft) | 33 | 33 | 33 | 33 | 33 |
| Ambient Temperature Cooling (°F) | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 |
| Ambient Temperature Heating (°F) | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 |
| Certification: AHRI | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: Energy Star | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: NEEP | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: ETL | ✔ | ✔ | ✔ | ✔ | ✔ |
Outdoor Hyper
| Specification | CH-RVHP19M-230VO | CH-RVHP28M-230VO | CH-RVHP36M-230VO | CH-RVHP48M-230VO | CH-RVHP55M-230VO |
|---|---|---|---|---|---|
| Power Supply (V/Ph/Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Operating Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Capacity (BTU/h) | 5,400~28,000 | 7,200~37,000 | 9,000~43,000 | 12,000~57,000 | 19,000~59,000 |
| SEER2 | 5.6 | 9.5 | 12 | 17.3 | 18.5 |
| EER | 15 | 12.5 | 13 | 12 | 12 |
| IEER | 25 | 23 | 23 | 23 | 22.2 |
| Heating Capacity (BTU/h) | 5,700~27,000 | 8,400~36,000 | 10,000~44,000 | 13,000~57,000 | 20,000~59,000 |
| HSPF2 | 6.5 | 9.1 | 11.5 | 17.3 | 20.1 |
| COP | 4 | 3.8 | 4 | 3.7 | 3.5 |
| SCOP | 10.4 | 10.5 | 10.7 | 11 | 10.5 |
| Power Input (W) | 8.5 | 8.5 | 8.5 | 9 | 8.5 |
| Air Flow (CFM) | 19,000 | 27,000 | 36,000 | 47,000 | 47,000 |
| Sound Level Indoor (dBA) | 17.5 | 30 | 37 | 37 | 39.5 |
| Sound Level Outdoor (dBA) | 20 | 35 | 40 | 40 | 40 |
| Weight Indoor (lbs) | 2,130.7 | 2,148.4 | 3,037.2 | 4,502.8 | 4,502.8 |
| Weight Outdoor (lbs) | 61.5 | 61 | 65 | 65 | 65 |
| Dimensions Indoor (in) | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 38.58x16.34x38.39 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Dimensions Outdoor (in) | 42.91x19.68x34.84 | 42.91x19.68x34.84 | 45.08x19.68x42.52 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Shipping Weight Indoor/Outdoor (lbs) | 137.35/148.15 | 168.43/179.67 | 211.86/244.71 | 246.47/276.68 | 246.47/276.68 |
| Refrigerant Type/Amount (lbs) | R454B/78.31 | R454B/120.63 | R454B/134.04 | R454B/151.68 | R454B/151.68 |
| Fuse Size (A) | 75 | 100 | 125 | 150 | 150 |
| Wire Size (AWG) | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 |
| Control Voltage (V) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Liquid Line | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 6 x 1/4" | 6 x 1/4" |
| Suction Line | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 3 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" |
| Max Line Length (ft) | 196.8 | 262.4 | 262.4 | 262.4 | 262.4 |
| Max Elevation Diff (ft) | 98.4 | 114.8 | 114.8 | 114.8 | 114.8 |
| Max Head Pressure (ft) | 49.2 | 49.2 | 49.2 | 49.2 | 49.2 |
| Max Suction Pressure (ft) | 33 | 33 | 33 | 33 | 33 |
| Operating Range Cooling (°F) | -22~122 | -22~122 | -22~122 | -22~122 | -22~122 |
| Operating Range Heating (°F) | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 |
| Feature 1 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 2 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 3 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 4 | ✓ | ✓ | ✓ | ✓ | ✓ |
Which system is right for you?
| Your selection | ||||
|---|---|---|---|---|
| Cooling Capacity | 48,000 BTU/h | 48,000 BTU/h | 48,000 BTU/h | 48,000 BTU/h |
| SEER2 Rating | 22.0 | 24.0 | 20.5 | 20.5 |
| Refrigerant | R454B | R454B | R454B | R454B |
| Zones | Six Zone | Dual Zone | Three Zone | Four Zone |
| Voltage | 230V | 230V | 230V | 230V |
| Shop Now → | Shop Now → | Shop Now → |
Frequently asked questions.
How many rooms can this Cooper & Hunter mini split system cool?
The Cooper & Hunter 6 Zone 48,000 BTU mini split can effectively cool up to six rooms, thanks to its multiple indoor units, which include configurations of 6K, 9K, and 12K BTU units. This setup is ideal for managing temperature across a larger space of up to 2000 sq ft.
Can I mix BTU sizes with the Cooper & Hunter mini split system?
Yes, the Cooper & Hunter mini split system allows for mixing BTU sizes across its zones, as seen with its combination of 6K, 9K, and 12K units. This flexibility enables you to tailor cooling capacity to the specific needs of different rooms.
Do all zones in the Cooper & Hunter multi-zone mini split run simultaneously?
No, not all zones in the Cooper & Hunter 6 Zone system must run simultaneously. You can selectively operate individual zones based on your cooling requirements, which can enhance efficiency and reduce energy consumption.
What are the efficiency benefits of the Cooper & Hunter mini split compared to multiple single-zone units?
The Cooper & Hunter 48,000 BTU mini split boasts a high SEER rating of 22.0, making it significantly more efficient than running multiple single-zone units. Using one multi-zone system can reduce energy usage and installation complexity while providing consistent temperature control.
What is the warranty on the Cooper & Hunter mini split system?
The Cooper & Hunter mini split system comes with a 5-year parts warranty and a 7-year compressor warranty, provided that you register the product within 30 days of purchase. This warranty offers peace of mind and protection for your investment.
Does the Cooper & Hunter mini split come pre-charged with refrigerant?
Yes, the Cooper & Hunter mini split system is pre-charged with R454B refrigerant for installations using up to 25 ft of line set. This feature simplifies installation and ensures optimal performance right from the start.
Manufacturer Technical Support
Reach your brand's tech support team directly
You may also like
- R454BSEER2 18.0HEATS down to −22°FCOOLS up to 122°F
7-Yr Warranty
Cooper & HunterCooper & Hunter Hyper Heat 6,000 BTU Single Zone Slim Duct, 230V, R454B - Ducted Mini Split Air Conditioner Heat PumpFree Shipping
- R32SEER2 22.0Heats & Cools
7-Yr Warranty
BravoBravo Pisa 9,000 BTU Single Zone Concealed Duct, 230V, R32 - Ductless Mini Split Heat PumpFree Shipping
- R454BSEER2 19.0HEATS down to −13°FCOOLS up to 122°F
7-Yr Warranty
Cooper & HunterCooper & Hunter 9,000 BTU Single Zone Slim Duct, 230V, R454B - Ducted Mini Split Air Conditioner Heat PumpFree Shipping
- R454BSEER2 18.0HEATS down to −22°FCOOLS up to 122°F
7-Yr Warranty
Cooper & HunterCooper & Hunter Hyper Heat 9,000 BTU Single Zone Slim Duct, 230V, R454B - Ducted Mini Split Air Conditioner Heat PumpFree Shipping
The Cooper & Hunter 6-Zone Mini Split System features a 48,000 BTU capacity, 24 SEER2 efficiency, and built-in Wi-Fi control for seamless temperature management across six zones. It utilizes R454B refrigerant and operates effectively in heating conditions as low as -13°F, ensuring reliable performance in colder climates.
Key Features
- 6-zone system — the CH-R48MES-230VO outdoor unit supports up to 6 independently controlled indoor units; port adapters included, no branch boxes required
- 48,000 BTU nominal system capacity across 6 zones, each on its own remote
- 24 SEER2 inverter efficiency — current R454B generation
- Heat pump — heats down to -13°F outdoor ambient
- R454B refrigerant, factory pre-charged; built-in Wi-Fi control
- Mix any Cooper & Hunter head types — wall mount, ceiling cassette, slim duct, floor/ceiling console