Cooper & Hunter Olivia 12,000 BTU Indoor Wall Mount, 230V, R410A - Ductless Mini Split Air Conditioner Heat Pump
Cooper & Hunter7-Yr WarrantySKU: CH-12MOLVWM-230VI
Product specifications
- Voltage
- 230V
- SEER
- 26.4
- WiFi
- Not Included
- Type
- Wall Mount
- Freon
R410A
Choose Your Configuration
“No Installation Kit” ships the units only.
Save 10% on these accessories
ARMBRIDGE Mini Split Wall Mounting Bracket High Load Capacity Zinc, Vibration-Absorbing (Up to 550 lbs Each)-10%$49.00
ARMBRIDGE Heavy-Duty Mini Split Ground Stand, Zinc-Coated Brackets for 24,000–60,000 BTU Units Weatherproof Design, 330+ lbs Capacity-10%$89.00
ARMBRIDGE 30 AMP Fusible Metallic Disconnect Box Durable Enclosed Disconnect for Residential and Light Commercial HVAC Systems-10%$29.00
ARMBRIDGE Non-Metallic A/C Whip 3/4" x 6 ft – Pre-Wired Liquid tight Conduit with 8/2 & 10/1 Wires for HVAC & Air Conditioner Power Connection-10%$34.00
Fast Delivery
Ships from the nearest of our three US warehouses, leaves in 1–2 business days. Shipping policy
COOPER & HUNTER · OLIVIA
Built for year-round comfort
CH-12MOLVWM-230VI
System Specs
| Cooling Capacity | 12,000 BTU/h |
|---|---|
| SEER2 | 26.4 |
| Voltage | 230V |
| Refrigerant | R410A |
| Compressor | Inverter |
|---|---|
| Sound Level (indoor) | 41.5/36/24 dB |
| Warranty | 7-Yr Compressor |
Indoor Unit Specs
| Unit Dimensions (WxDxH) | Net / Gross Weight | Remote Control |
|---|---|---|
| 31.57 × 7.87 × 11.61 in | 18.74 / 24.25 lb | RG10K-exclusive remote |
Olivia Series Description
The Cooper & Hunter 12,000 BTU wall mount is a wall mount indoor unit for Cooper & Hunter ductless mini split systems, running on R410A refrigerant. It mounts in a single room or zone and is controlled independently with its included remote — pair it with a compatible outdoor condenser to complete your system.
6 Modes for Maximum Comfort
Engineered to adapt to every season, every room, every need.
Maintain a comfortable indoor temperature by automatically switching between heating and cooling as needed. Ideal for year-round use.
WARRANTY
BACKED BY COOPER & HUNTER
Industry-leading protection on every unit
Compressor: 7-year coverage
With product registration after professional installation.
Parts & components: 5-year coverage
All major components and refrigerant circuit parts.
Technical Specifications
Indoor Unit Specs— CH-12MOLVWM-230VI
| Model | CH-12MOLVWM-230VI |
|---|---|
| Unit Dimensions (WxDxH) | 31.57x7.87x11.61 in |
| Net/Gross Weight | 18.74/24.25 lb |
| Packing Dimensions (WxDxH) | 34.45x11.22x14.96 in |
| Power Supply | 208-230V, 1Ph, 60Hz |
| Maximum Fuse Size | 15 A |
| Min. Circuit Ampacity | 3 A |
| Copper Line Size (Liquid/Gas) | 1/4" - 1/2'' |
| Noise Level (Hi/Med/Lo) | 41.5/36/24 dB |
| Airflow (Turbo/Hi/Mi/Lo) | 341.18/291.18/194.12/152.94 CFM |
| Dehumidification | 3.06 pt/h |
| Drain Pipe Diameter | 5/8" |
| Controller | RG10K-exclusive remote |
Series Comparison Table
Technical specifications for every model in the series — this product is one of them.
Indoor Models Hyper
| Specification | CH-06MOLVWM-230WI | CH-09MOLVWM-230WI | CH-12MOLVWM-230WI | CH-18MOLVWM-230WI | CH-24MOLVWM-230WI |
|---|---|---|---|---|---|
| Power Supply Rated (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity (Btu/h) | 6,000 | 9,000 | 12,000 | 18,000 | 24,000 |
| Minimum Circuit Ampacity (MCA) (A) | 3 | 3 | 3 | 3 | 3 |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) | 294/247/176/141 | 341/291/194/152 | 341/291/194/152 | 768/530/458/382 | 790/601/459/382 |
| Indoor Noise Level (Hi/Mi/Lo) dB(A) | 38.5/30/20.5 | 40/35/23.5 | 41.5/36/24 | 46/40/25 | 46.5/44/35 |
| Dimension (WxDxH) (inch) | 28.70x7.87x11.30 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 42.64x9.61x13.23 | 42.68x9.21x13.27 |
| Packing (WxDxH) (inch) | 31.10x10.83x14.76 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 45.47x16.34x12.40 | 45.47x16.34x12.40 |
| Net/Gross Weight (lbs.) | 17.64/22.49 | 18.96/24.25 | 18.74/24.25 | 29.54/37.48 | 29.98/38.14 |
| Room Temperature Cooling (°F) | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 |
| Room Temperature Heating (°F) | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 |
| Liquid Side/Gas Side (inch) | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 1/2" | 1/4" / 1/2" | 3/8" / 5/8" |
Indoor Models Regular
| Specification | CH-060LVWM-115VI | CH-090LVWM-115WI | CH-120LVWM-115WI | CH-09MOLVWM-230VI | CH-12MOLVWM-230WI | CH-18MOLVWM-230WI | CH-24MOLVWM-230WI |
|---|---|---|---|---|---|---|---|
| Power Supply Rated (V, Ph, Hz) | 115V, 1, 60 | 115, 1, 60 | 115, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity (Btu/h) | 7,000 | 9,000 | 12,000 | 9,000 | 12,000 | 18,000 | 24,000 |
| Minimum Circuit Ampacity (MCA) (A) | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo) (CFM) | 341/300/241/176 | 341/300/241/176 | 341/300/241/176 | 291.18/194.12/152.94 | 341/291/194/152 | 768/530/458/382 | 790/601/459/382 |
| Indoor Noise Level (Hi/Mi/Lo) dB(A) | 41.5/36/24 | 41.5/36/24 | 41.5/36/24 | 40/34/23.5 | 42/36/25 | 45.5/41/24.5 | 48/40/28 |
| Dimension (WxDxH) (inch) | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 31.57x7.87x11.61 | 42.64x9.61x13.23 | 42.68x9.21x13.27 |
| Packing (WxDxH) (inch) | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 45.47x16.34x12.40 | 45.47x16.34x12.40 |
| Net/Gross Weight (lbs.) | 18.96/24.47 | 18.96/24.47 | 18.96/24.47 | 18.96/24.25 | 18.74/24.25 | 29.54/37.48 | 29.98/38.14 |
| Room Temperature Cooling (°F) | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 | 60 - 90 |
| Room Temperature Heating (°F) | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 | 32 - 86 |
| Liquid Side/Gas Side (inch) | 1/4" / 1/2" | 1/4" / 1/2" | 1/4" / 1/2" | 1/4" / 3/8" | 1/4" / 1/2" | 1/4" / 1/2" | 3/8" / 5/8" |
Outdoor Models Regular
| Specification | ES-Series |
|---|---|
| CH-18MES-230V0 | CH-28MES-230V0 |
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 |
| Voltage Range (V) | 187-253 |
| Cooling Rated Capacity (Btu/h) | 18,000(5,650~22,000) |
| Cooling Rated Current (A) | 6.2 |
| EER2 (Btu/h) | 13.9 |
| SEER2 (Btu/h) | 22.9 |
| Heating Rated Capacity (Btu/h) | 19,000(5,050~24,400) |
| Heating Rated Current (A) | 6.3 |
| Heating at 47°F COP (W/W) | 3.74 |
| HSPF4 | 10.5 |
| HSPF5 | 8 |
| Heating at 5°F Rated Capacity (Btu/h) | 12,600 |
| Heating at 5°F COP (W/W) | 2 |
| Minimum Circuit Ampacity (Outdoor unit) (A) | 18 |
| Max. Fuse (Outdoor unit) (A) | 25 |
| Outdoor Air Flow (Max) (CFM) | 1,765 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 58 |
| Dimension (WxDxH) (inch) | 35.04x13.46x26.50 |
| Packing (WxDxH) (inch) | 40.55x17.24x29.53 |
| Net/Gross Weight | 100/109 |
| Refrigerant Type/Charged (oz) | R410A/65.26 |
| Refrigerant Precharge (ft) | 49 |
| Additional Charge for Each (oz/ft) | 0.16 |
| Design Pressure (PSIG) | 550/340 |
| Refrigerant Piping Liquid Side (inch) | 2 x 1/4" |
| Refrigerant Piping Gas Side (inch) | 2 x 3/8" |
| Max. Pipe Length (ft) | 131 |
| Max. Length for One Indoor Unit (ft) | 82 |
| Max. Height Difference in Level (ft) | 49 |
| Max. Height Difference Between Indoor Units (ft) | 33 |
| Ambient Temperature Cooling (°F) | 5~122 |
| Ambient Temperature Heating (°F) | -13~75 |
| AHRI | ✔ |
| Energy Star | ✔ |
| NEEP | ✔ |
Outdoor Models Hyper
| Specification | CH-HPR19M-230V0 | CH-HPR28M-230V0 | CH-HPR36M-230V0 | CH-HPR48M-230VO | CH-HPR55M-230V0 |
|---|---|---|---|---|---|
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Rated Capacity (Btu/h) | 19,000 (5,500~-25,000) | 28,000(7,995-32,826) | 36,000(17,900~42,000) | 48,000 (19,300-51,000) | 55,000(11,600~58,000) |
| Cooling Rated Current (A) | 9.1 | 12.4 | 11.8 | 18 | 23.5 |
| EER2 (Btu/h) | 12.5 | 12.5 | 13.6 | 11.7 | 10.5 |
| SEER2 (Btu/h) | 22 | 23 | 22.2 | 21.8 | 22 |
| Heating Rated Capacity (Btu/h) | 20,000(8,100~29,700) | 28,000(5,035~38,712) | 36,500(12,500~49,000) | 49,000(11,500~58,000) | 55,000(33,000~63,000) |
| Heating Rated Current (A) | 9.4 | 10.5 | 12.2 | 17.8 | 22.5 |
| Heating at 47°F COP (W/W) | 3.4 | 3.66 | 3.9 | 3.8 | 3.05 |
| HSPF4 | 9.8 | 10.6 | 10.3 | 9.8 | 9.3 |
| HSPF5 | 7.7 | 8.1 | 8.3 | 7.6 | 7.3 |
| Heating at 5°F Rated Capacity (Btu/h) | 19,000 | 24,000 | 36,000 | 48,000 | 37,800 |
| Heating at 5°F COP (W/W) | 1.96 | 1.75 | 1.9 | 2 | 1.8 |
| Minimum Circuit Ampacity (Outdoor unit) (A) | 20 | 25 | 40 | 42 | 40 |
| Max. Fuse (Outdoor unit) (A) | 25 | 40 | 60 | 50 | 60 |
| Outdoor Air Flow (Max) (CFM) | 2,129 | 2,147 | 4,500 | 4,500 | 4,500 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 61 | 63 | 63 | 65 | 62 |
| Dimension (WxDxH) (inch) | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Packing (WxDxH) (inch) | 42.91x19.69x34.84 | 42.91x19.69x34.84 | 43.11x19.49x58.27 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Net/Gross Weight | 138/149 | 168/179 | 223/254 | 238/270 | 233/266 |
| Refrigerant Type/Charged (oz) | R410A/91.7 | R410A/134.04 | R410A/162 | R410A/162 | R410A/162 |
| Refrigerant Precharge (ft) | 49 | 74 | 98 | 123 | 123 |
| Additional Charge for Each (oz/ft) | 0.16 | 0.16 - *0.32 | 0.16 - *0.32 | 0.16 - *0.32 | 0.16 -*0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side (inch) | 2 x 1/4" | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 5 x 1/4" |
| Refrigerant Piping Gas Side (inch) | 2 x 3/8" | 2 x 3/8" +1 x 1/2" | 3 x 3/8" +1 x 1/2" | 3 x 3/8" + 2 x 1/2" | 3 x 3/8" +2 x 1/2" |
| Max. Pipe Length (ft) | 131 | 197 | 262 | 262 | 262 |
| Max. Length for One Indoor Unit (ft) | 82 | 98 | 115 | 115 | 115 |
| Max. Height Difference in Level (ft) | 49 | 49 | 49 | 49 | 49.21 |
| Max. Height Difference Between Indoor Units (ft) | 33 | 33 | 33 | 33 | 33 |
| Ambient Temperature Cooling (°F) | 5~122 | 5~122 | 5~122 | 5~122 | 5~122 |
| Ambient Temperature Heating (°F) | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 |
Frequently asked questions.
What size mini split do I need for my room?
For a space up to 550 sq ft, the Cooper & Hunter Olivia 12,000 BTU ductless mini split is ideal. This system efficiently provides cooling and heating for medium-sized rooms.
How much does a mini split system like the Cooper & Hunter Olivia cost?
The price of the Cooper & Hunter Olivia 12,000 BTU mini split varies based on installation options, with choices available for no kit, 16ft, 25ft, and 50ft line sets. Be sure to check current prices for the most accurate estimate.
Can I install the Cooper & Hunter Olivia mini split myself?
While some homeowners may attempt a DIY installation, it’s recommended to hire a professional, especially for the Cooper & Hunter Olivia 12,000 BTU system, to ensure proper setup and compliance with local codes.
Does the Cooper & Hunter Olivia mini split come pre-charged with refrigerant?
Yes, the Cooper & Hunter Olivia is pre-charged with R410A refrigerant for up to 25 ft of line set, making installation more straightforward, though additional charging may be necessary for longer runs.
What voltage does the Cooper & Hunter Olivia mini split require?
The Cooper & Hunter Olivia 12,000 BTU mini split operates on a 230V power supply, which is standard for many residential installations.
What warranty does the Cooper & Hunter Olivia offer?
The Cooper & Hunter Olivia provides a solid warranty, featuring a 5-year parts and 7-year compressor warranty, but registration is required within 30 days of purchase to activate these terms.
Manufacturer Technical Support
Reach your brand's tech support team directly
You may also like
- R410ASEER2 26.4Heats & Cools
7-Yr Warranty
Cooper & HunterCooper & Hunter Midnight Black 6,000 BTU Indoor Wall Mount, 230V, R410A - Ductless Mini Split Air Conditioner Heat Pump - R32Heats & Cools
7-Yr Warranty
BravoBravo Milano 9,000 BTU Indoor Wall Mount, 230V, R32 - Ductless Mini Split Air Conditioner Heat Pump - R32Heats & Cools
7-Yr Warranty
BravoBravo Milano 12,000 BTU Indoor Wall Mount, 230V, R32 - Ductless Mini Split Air Conditioner Heat Pump - R410ASEER2 22.0Heats & Cools
5-Yr Warranty
OLMOOLMO Sierra 18,000 BTU Indoor Wall Mount, 230V, R410A - Ductless Mini Split Air Conditioner Heat Pump
The Cooper & Hunter 12,000 BTU wall mount is a wall mount indoor unit for Cooper & Hunter ductless mini split systems, running on R410A refrigerant. It mounts in a single room or zone and is controlled independently with its included remote — pair it with a compatible outdoor condenser to complete your system.
Key Features
- Wall Mount indoor unit for Cooper & Hunter multi-zone / single-zone systems
- 12,000 BTU nominal capacity
- Individually controlled with included remote — set its own temperature per room
- R410A refrigerant
- Inverter heat pump — cools and heats when paired with a compatible condenser
Works With
Connects to a compatible Cooper & Hunter outdoor condenser (multi-zone or single-zone), sold separately. Choose a copper line-set kit length at checkout, or supply your own.