Cooper & Hunter Olivia 60,000 BTU 3-Zone 6k+18k+36k Wall Mount, 230V, R454B - Ductless Mini Split Air Conditioner Heat Pump
Cooper & Hunter7-Yr WarrantySKU: CH-R60MES-230VO/M06WM+M18WM+M36WM-NO/NO/NO
Product specifications
- Voltage
- 230V
- SEER
- 22.0
- WiFi
- Included
- Zone
- Three Zone
- Type
- Wall Mount
- Freon
R454B
Choose Your Configuration
Choose a line-set kit length for each indoor unit. “No Installation Kit” ships the units only.
Size — match your room area
Save 10% on these accessories
ARMBRIDGE Mini Split Wall Mounting Bracket High Load Capacity Zinc, Vibration-Absorbing (Up to 550 lbs Each)-10%$49.00
ARMBRIDGE Heavy-Duty Mini Split Ground Stand, Zinc-Coated Brackets for 24,000–60,000 BTU Units Weatherproof Design, 330+ lbs Capacity-10%$89.00
ARMBRIDGE 30 AMP Fusible Metallic Disconnect Box Durable Enclosed Disconnect for Residential and Light Commercial HVAC Systems-10%$29.00
ARMBRIDGE Non-Metallic A/C Whip 3/4" x 6 ft – Pre-Wired Liquid tight Conduit with 8/2 & 10/1 Wires for HVAC & Air Conditioner Power Connection-10%$34.00
FREE Delivery
Ships from the nearest of our three US warehouses, leaves in 1–2 business days. Shipping policy
COOPER & HUNTER · OLIVIA
Built for year-round comfort
CH-R60MES-230VO/M06WM+M18WM+M36WM-NO/NO/NO
System Specs
| Cooling Capacity | 60,000 BTU/h |
|---|---|
| Heating Capacity | 60,000 BTU/h |
| SEER2 | 22 |
| EER2 | 10 |
| Voltage | 230V |
| Refrigerant | R454B |
|---|---|
| Compressor | Inverter |
| Climate Range | -13–122°F / -13–75°F outdoor ambient |
| Sound Level (indoor) | 37/32/24 dB |
| Warranty | 7-Yr Compressor |
Indoor Unit Specs
| Unit Dimensions (WxDxH) | Net / Gross Weight | Remote Control |
|---|---|---|
| 28.70 × 7.87 × 11.50 in | 17.64 / 23.15 lb | Remote controller |
Olivia Series Description
The Cooper & Hunter Olivia 3-Zone Mini Split System features three wall-mounted zones with capacities of 6,000, 18,000, and 36,000 BTU, supported by an outdoor unit rated for 60,000 BTU nominal cooling and operation down to -13°F ambient temperature. It includes built-in Wi-Fi control, uses R454B refrigerant, and achieves a SEER2 efficiency rating of 22.
6 Modes for Maximum Comfort
Engineered to adapt to every season, every room, every need.
Maintain a comfortable indoor temperature by automatically switching between heating and cooling as needed. Ideal for year-round use.
WHEREVER YOU ARE
Control your comfort, your way
- Easy scheduling & timer
- Multiple ways to control your comfort
- Smart geo location
- In-app support & assistance
- Voice control

IN THE BOX
Everything included with this system
- Cooper & Hunter MES 60,000 BTU Outdoor Condenser, 230V, R454B - Mini Split Air Conditioner Heat Pump
- Indoor Wall Mount — CH-R06MOLVWM-230VI
- Indoor Wall Mount — CH-R18MOLVWM-230VI
- Indoor Wall Mount — CH-R36MELVWM-230VI
WARRANTY
BACKED BY COOPER & HUNTER
Industry-leading protection on every unit
Compressor: 7-year coverage
With product registration after professional installation.
Parts & components: 5-year coverage
All major components and refrigerant circuit parts.
Technical Specifications
Outdoor Unit Specs— CH-R60MES-230VO
| Model | CH-R60MES-230VO |
|---|---|
| Unit Dimensions (WxDxH) | 37.48 x 16.34 x 52.48 in |
| Net/Gross Weight | 237.88/270.28 lb |
| Packing Dimensions (WxDxH) | 43.11 x 19.49 x 58.27 in |
| Power Supply | 208-230V, 1Ph, 60Hz |
| Maximum Fuse Size | 40 A |
| Min. Circuit Ampacity | 36 A |
| Copper Line Size (Liquid/Gas) | 6x1/4" - 4x3/8"+2x1/2" |
| Noise Level | 65 dB |
| Airflow | 4,502.8 CFM |
| Dehumidification | 10.57 pt/h |
Indoor Unit Specs
| Model | CH-R06MOLVWM-230VI | CH-R18MOLVWM-230VI | CH-R36MELVWM-230VI |
|---|---|---|---|
| Unit Dimensions (WxDxH) | 28.70 x 7.87 x 11.50 in | 42.60 x 9.21 x 13.27 in | 49.57 x 11.14 x 14.25 in |
| Net/Gross Weight | 17.64/23.15 lb | 30.42/39.68 lb | 43.43/56.88 lb |
| Packing Dimensions (WxDxH) | 31.10 x 10.63 x 14.76 in | 45.47 x 16.34 x 12.40 in | 52.76 x 17.72 x 15.16 in |
| Power Supply | 208-230V, 1Ph, 60Hz | 208-230V, 1Ph, 60Hz | 208-230V, 1Ph, 60Hz |
| Maximum Fuse Size | 15 A | 15 A | 15 A |
| Min. Circuit Ampacity | 3 A | 3 A | 3 A |
| Copper Line Size (Liquid/Gas) | 1/4"/3/8" | 1/4"/1/2" | 3/8"/5/8" |
| Noise Level (Hi/Med/Lo) | 37/32/24 dB | 45/40/24.5 dB | 51/45/33.5 dB |
| Dehumidification | 0.63 pt/h | 3.81 pt/h | 10.78 pt/h |
| Drain Pipe Diameter | 5/8" | 5/8" | 5/8" |
| Controller | remote controller | remote controller | remote controller |
System Specs
| Cooling — Rated Capacity (Range) | 60,000 Btu/h (19,000–62,000) |
|---|---|
| Heating at 47°F — Rated Capacity (Range) | 60,000 Btu/h (20,000–60,000) |
| Rated Heating at 5°F | 39,000 Btu/h |
| SEER2 / EER2 | 22 / 10 |
| HSPF4 / HSPF5 / COP (47°F) | 9.5 / 7.4 / 3.7 |
| Outdoor Unit MCA / Max. Fuse | 36 A / 40 A |
| Max. Connectable Indoor Units | 6 |
| Outdoor Noise Level | 65 dB(A) |
| Outdoor Unit Dimensions (W×D×H) | 37.48 × 16.34 × 52.48 in |
| Outdoor Unit Net / Gross Weight | 237.88 / 270.28 lbs |
| Refrigerant Type / Charge | R454B / 151.68 oz |
| Pre-charged Line Length | 150 ft (add 0.16 oz/ft for 1/4 in liquid pipe / 0.32 oz/ft for 3/8 in liquid pipe) |
| Max. Total Pipe Length / Max. to One Indoor | 262.4 ft / 114.8 ft |
| Max. Height Difference (Indoor–Outdoor / Between Indoors) | 49.2 ft / 33 ft |
| Operating Range — Cooling / Heating | -13–122°F / -13–75°F outdoor ambient |
Series Comparison Table
Technical specifications for every model in the series — this product is one of them.
Indoor and Outdoor Hyper
| Specification | CH-R06MOLVWM-115VI | CH-R09MOLVWM-230VI | CH-R12MOLVWM-230VI | CH-R18MOLVWM-230VI | CH-R24MOLVWM-230VI | CH-R33HEMLVWM-230VI |
|---|---|---|---|---|---|---|
| Power Supply Rated | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity Btu/h | 6,000 | 9,000 | 12,000 | 18,000 | 23,000 | 33,000 |
| Minimum Circuit Ampacity (MCA) A | 3 | 3 | 3 | 3 | 3 | 3 |
| Max. Fuse A | 3 | 3 | 3 | 3 | 3 | 3 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) CFM | 294.3/225.4/176.8/141.3/NA | 382.6/293.1/194.2/153.0/NA | 382.6/293.1/194.2/153.0/NA | 759.3/530.4/419.1/382.6/NA | 759.3/586.5/419.1/382.6/NA | 829.6/716.6/592.7/447.3/NA |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) dB(A) | 42.0/37.0/32.0/24.0/NA | 42.0/37.0/32.0/24.0/NA | 43.0/37.0/32.0/24.0/NA | 52.5/44.0/40.5/35.2/25.0 | 54.5/49.0/45.3/41.3/27.0 | 56.0/49.5/45.3/41.3/27.0 |
| Dimension (WxDxH) inch | 28.7x7.87x11.81 | 31.5x7.87x11.61 | 31.5x7.87x11.61 | 45.47x12.01x16.14 | 45.47x12.01x16.14 | 52.76x15.16x17.72 |
| Packing (WxDxH) inch | 31.10x10.63x14.76 | 34.45x11.22x14.96 | 34.45x11.22x14.96 | 45.47x12.01x16.14 | 45.47x12.01x16.14 | 52.76x15.16x17.72 |
| Net/Gross Weight lbs. | 17.64/21.35 | 18.64/22.05 | 18.64/22.05 | 45.47/21.06 | 45.47/21.06 | 67.16/17.72 |
| Room temperature Cooling °F | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 |
| Room temperature Heating °F | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 |
| Liquid Side/Gas Side inch | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 1/2" | 3/8" / 5/8" | 3/8" / 3/4" |
Specification
| Specification | CH-RVHP19M-230VO | CH-RVHP28M-230VO | CH-RVHP36M-230VO | CH-RVHP48M-230VO | CH-RVHP55M-230VO |
|---|---|---|---|---|---|
| Power Supply (V/Ph/Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Operating Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Capacity (BTU/h) | 5,400~28,000 | 7,200~37,000 | 9,000~43,000 | 12,000~57,000 | 19,000~59,000 |
| Rated Current | 5.6 | 9.5 | 12 | 17.3 | 18.5 |
| EER2 | 15 | 12.5 | 13 | 12 | 12 |
| SEER2 | 25 | 23 | 23 | 23 | 22.2 |
| Heating Capacity (BTU/h) | 5,700~27,000 | 8,400~36,000 | 10,000~44,000 | 13,000~57,000 | 20,000~59,000 |
| HSPF2 | 6.5 | 9.1 | 11.5 | 17.3 | 20.1 |
| COP | 4 | 3.8 | 4 | 3.7 | 3.5 |
| SCOP | 10.4 | 10.5 | 10.7 | 11 | 10.5 |
| Power Input (W) | 8.5 | 8.5 | 8.5 | 9 | 8.5 |
| Air Flow (CFM) | 19,000 | 27,000 | 36,000 | 47,000 | 47,000 |
| Sound Level Indoor (dBA) | 17.5 | 30 | 37 | 37 | 39.5 |
| Sound Level Outdoor (dBA) | 20 | 35 | 40 | 40 | 40 |
| Weight Indoor (lbs) | 2,130.7 | 2,148.4 | 3,037.2 | 4,502.8 | 4,502.8 |
| Weight Outdoor (lbs) | 61.5 | 61 | 65 | 65 | 65 |
| Dimensions Indoor (in) | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 38.58x16.34x38.39 | 37.48x16.34x52.48 | 37.48x16.34x52.48 |
| Dimensions Outdoor (in) | 42.91x19.68x34.84 | 42.91x19.68x34.84 | 45.08x19.68x42.52 | 43.11x19.49x58.27 | 43.11x19.49x58.27 |
| Shipping Weight Indoor/Outdoor (lbs) | 137.35/148.15 | 168.43/179.67 | 211.86/244.71 | 246.47/276.68 | 246.47/276.68 |
| Refrigerant Type/Amount (lbs) | R454B/78.31 | R454B/120.63 | R454B/134.04 | R454B/151.68 | R454B/151.68 |
| Fuse Size (A) | 75 | 100 | 125 | 150 | 150 |
| Wire Size (AWG) | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 |
| Control Voltage (V) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Liquid Line | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 6 x 1/4" | 6 x 1/4" |
| Suction Line | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 3 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" | 4 x 3/8" + 2 x 1/2" |
| Max Line Length (ft) | 196.8 | 262.4 | 262.4 | 262.4 | 262.4 |
| Max Elevation Diff (ft) | 98.4 | 114.8 | 114.8 | 114.8 | 114.8 |
| Max Head Pressure (ft) | 49.2 | 49.2 | 49.2 | 49.2 | 49.2 |
| Max Suction Pressure (ft) | 33 | 33 | 33 | 33 | 33 |
| Operating Range Cooling (°F) | -22~122 | -22~122 | -22~122 | -22~122 | -22~122 |
| Operating Range Heating (°F) | -22~75 | -22~75 | -22~75 | -22~75 | -22~75 |
| Feature 1 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 2 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 3 | ✓ | ✓ | ✓ | ✓ | ✓ |
| Feature 4 | ✓ | ✓ | ✓ | ✓ | ✓ |
Indoor and Outdoor Regular
| Specification | CH-R060LVWM-115VI | CH-R09OLVWM-115VI | CH-R120LVWM-115VI | CH-RO9MOLVWM-230VI | CH-R12MOLVWM-230VI | CH-R18MOLVWM-230VI | CH-R24MOLVWM-230VI | CH-R30MELVWM-230VI | CH-R36MELVWM-230VI |
|---|---|---|---|---|---|---|---|---|---|
| Power Supply Rated | 115V, 1, 60 | 115V, 1, 60 | 115V, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Rated Capacity Btu/h | 7,000 | 9,000 | 12,000 | 9,000 | 12,000 | 18,000 | 24,000 | 30,000 | 36,000 |
| Minimum Circuit Ampacity (MCA) A | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
| Max. Fuse A | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) CFM | 370/340/265/174/- | 378/340/265/174/- | 378/340/265/174/- | 382/294/194/153/- | 382/294/194/153/- | 759/530/419/382/- | 759/586/419/382/- | 871/716/547/447/- | 871/716/547/447/- |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) dB(A) | 44/40/35/26/- | 44/40/35/26/- | 44/40/35/26/- | 45/41/32/24/- | 45/41/32/24/- | 54/49/45/41/27 | 54/49/45/41/27 | 56/52/45/38/22 | 56/52/45/38/22 |
| Dimension (WxDxH) inch | 31.57x7.87x11.95 | 31.57x7.87x11.95 | 31.57x7.87x11.95 | 31.57x7.87x11.95 | 31.57x7.87x11.95 | 45.47x12.01x16.34 | 45.47x12.01x16.34 | 49.57x11.14x14.25 | 49.57x11.14x14.25 |
| Packing (WxDxH) inch | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 34.92x13.27x24.02 | 42.91x19.09x34.84 | 42.91x19.09x34.84 | 42.91x19.09x34.84 | 42.91x19.09x34.84 |
| Net/Gross Weight lbs. | 18.64/22.05 | 18.64/22.05 | 18.64/22.05 | 18.64/22.05 | 18.64/22.05 | 45.47/21.06 | 45.47/21.06 | 67.16/17.72 | 67.16/17.72 |
| Room temperature Cooling °F | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 |
| Room temperature Heating °F | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 |
| Liquid Side/Gas Side inch | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 3/8" | 1/4" / 1/2" | 3/8" / 5/8" | 3/8" / 5/8" | 3/8" / 5/8" |
Specification
| Specification | CH-R60MES-230VOThis model | CH-R18MES-230VO | CH-R28MES-230VO | CH-R36MES-230VO | CH-R48MES-230VO |
|---|---|---|---|---|---|
| Power Supply (V, Ph, Hz) | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 | 208/230, 1, 60 |
| Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling Rated Capacity (range) (Btu/h) | 19,000~62,000 | 5,400~21,600 | 7,200~32,000 | 9,000~42,000 | 12,000~55,000 |
| Cooling Rated Current (A) | 26.2 | 6 | 9.2 | 13.5 | 16.6 |
| EER2 | 10 | 14 | 13 | 12 | 12.5 |
| SEER2 | 22 | 25.1 | 25 | 24 | 24 |
| Heating Rated Capacity (range) (Btu/h) | 20,000~60,000 | 5,700~21,600 | 8,400~29,000 | 10,000~42,500 | 13,000~53,000 |
| Heating Rated Current (A) | 21 | 6.8 | 9.2 | 14 | 16.3 |
| Heating at 47°F COP (W/W) | 3.7 | 3.8 | 3.8 | 3.5 | 3.8 |
| HSPF4 | 9.5 | 9.8 | 9.5 | 9.5 | 10.3 |
| HSPF5 | 7.4 | 7.8 | 7 | 7 | 8 |
| Heating at 5°F Rated Capacity (Btu/h) | 39,000 | 13,500 | 19,000 | 26,000 | 36,000 |
| Minimum Circuit Ampacity (Outdoor unit) (A) | 40 | 16 | 23 | 30.5 | 40 |
| Max. Fuse (Outdoor unit) (A) | 45 | 20 | 25 | 35 | 45 |
| Outdoor Air Flow (Max) (CFM) | 4,502.8 | 1,765.8 | 2,130.7 | 2,148.4 | 4,502.8 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 65 | 59.5 | 61 | 64.5 | 63 |
| Dimension (W×D×H) (inch) | 37.48x16.34x52.48 | 35.04x13.46x26.50 | 37.24x16.14x31.89 | 37.24x16.14x31.89 | 37.48x16.34x52.48 |
| Packing (W×D×H) (inch) | 43.11x19.49x58.27 | 40.55x17.24x29.53 | 42.91x19.68x34.84 | 42.91x19.68x34.84 | 43.11x19.49x58.27 |
| Net/Gross Weight (lbs) | 237.88/270.28 | 100.53/109.35 | 138.89/149.69 | 168.87/180.12 | 222.00/254.19 |
| Refrigerant Type/Charged (oz) | R454B/151.68 | R454B/61.73 | R454B/84.66 | R454B/120.63 | R454B/148.15 |
| Refrigerant Precharge (ft) | 150 | 75 | 100 | 125 | 150 |
| Additional Charge for Each (0.16 for 1/4 in liquid pipe / *0.32 for 3/8 in liquid pipe) (oz/ft) | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 | 0.16 / 0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping Liquid Side (inch) | 6 x 1/4" | 3 x 1/4" | 4 x 1/4" | 5 x 1/4" | 6 x 1/4" |
| Refrigerant Piping Gas Side (inch) | 4 x 3/8" + 2 x 1/2" | 3 x 3/8" | 3 x 3/8" + 1 x 1/2" | 4 x 3/8" + 1 x 1/2" | 4 x 3/8" + 2 x 1/2" |
| Max. Pipe Length (ft) | 262.4 | 196.8 | 262.4 | 262.4 | 262.4 |
| Max. Length for One Indoor Unit (ft) | 114.8 | 98.4 | 114.8 | 114.8 | 114.8 |
| Max. Height Difference in Level (ft) | 49.2 | 49.2 | 49.2 | 49.2 | 49.2 |
| Max. Height Difference Between Indoor Units (ft) | 33 | 33 | 33 | 33 | 33 |
| Ambient Temperature Cooling (°F) | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 |
| Ambient Temperature Heating (°F) | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 |
| Certification: AHRI | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: Energy Star | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: NEEP | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification: ETL | ✔ | ✔ | ✔ | ✔ | ✔ |
Which system is right for you?
| Your selection | ||||
|---|---|---|---|---|
| Cooling Capacity | 60,000 BTU/h | 60,000 BTU/h | 60,000 BTU/h | 60,000 BTU/h |
| SEER2 Rating | 22.0 | 22.0 | 22.0 | 25.0 |
| Refrigerant | R454B | R454B | R454B | R454B |
| Zones | Three Zone | Dual Zone | Three Zone | Four Zone |
| Voltage | 230V | 230V | 230V | 230V |
| Shop Now → | Shop Now → | Shop Now → |
Frequently asked questions.
How many rooms can the Cooper & Hunter Olivia 60,000 BTU mini split cool?
The Cooper & Hunter Olivia 60,000 BTU ductless mini split is designed to effectively cool or heat up to three zones, accommodating multiple rooms in a space of up to 2500 sq ft.
Can I mix BTU sizes for different zones with the Cooper & Hunter Olivia?
Yes, you can mix BTU sizes for the three zones with the Cooper & Hunter Olivia, as long as the combined BTU does not exceed the system's capacity of 60,000 BTU. This flexibility allows you to customize the cooling and heating based on the specific needs of each room.
Do all zones in the Cooper & Hunter Olivia mini split run simultaneously?
No, the zones in the Cooper & Hunter Olivia can be controlled independently, allowing you to run only the zones that need heating or cooling, which can enhance energy efficiency compared to running multiple single-zone units.
What is the warranty on the Cooper & Hunter Olivia mini split system?
The Cooper & Hunter Olivia comes with a generous warranty offering 5-year parts coverage and a 7-year compressor warranty, provided you register the product within 30 days of purchase.
Does the Cooper & Hunter Olivia mini split come pre-charged with refrigerant?
Yes, the Cooper & Hunter Olivia mini split is pre-charged with R454B refrigerant for up to 25 ft of line set, making installation more straightforward and efficient.
What SEER rating does the Cooper & Hunter Olivia mini split have?
The Cooper & Hunter Olivia boasts an impressive SEER rating of 22.0, which signifies high energy efficiency, making it an excellent choice for both heating and cooling in various climates.
Manufacturer Technical Support
Reach your brand's tech support team directly
You may also like
- R454BSEER2 24.6HEATS down to −13°FCOOLS up to 122°F
7-Yr Warranty
Cooper & HunterCooper & Hunter Olivia 9,000 BTU Single Zone Wall Mount, 230V, R454B - Ductless Mini Split Air Conditioner Heat PumpFree Shipping
- R454BSEER2 23.2HEATS down to −13°FCOOLS up to 122°F
7-Yr Warranty
Cooper & HunterCooper & Hunter Olivia 12,000 BTU Single Zone Wall Mount, 115V, R454B - Ductless Mini Split Air Conditioner Heat PumpFree Shipping
- R454BSEER2 24.0HEATS down to −22°FCOOLS up to 122°F
7-Yr Warranty
Cooper & HunterCooper & Hunter Olivia Hyper Heat 12,000 BTU Single Zone Wall Mount, 230V, R454B - Ductless Mini Split Air Conditioner Heat PumpFree Shipping
- R454BSEER2 24.0HEATS down to −13°FCOOLS up to 122°F
7-Yr Warranty
Cooper & HunterCooper & Hunter Olivia 18,000 BTU Single Zone Wall Mount, 230V, R454B - Ductless Mini Split Air Conditioner Heat PumpFree Shipping
The Cooper & Hunter Olivia 3-Zone Mini Split System features three wall-mounted zones with capacities of 6,000, 18,000, and 36,000 BTU, supported by an outdoor unit rated for 60,000 BTU nominal cooling and operation down to -13°F ambient temperature. It includes built-in Wi-Fi control, uses R454B refrigerant, and achieves a SEER2 efficiency rating of 22.
Key Features
- 3-zone system — the CH-R60MES-230VO outdoor unit supports up to 6 indoor units, each individually controlled; port adapters included, no branch boxes required
- 60,000 Btu/h rated cooling / 60,000 Btu/h rated heating — inverter range 19,000–62,000 cooling, 20,000–60,000 heating (Btu/h)
- 22 SEER2 / 10 EER2 / 9.5 HSPF4 — current R454B-generation efficiency
- Heats down to -13°F outdoor ambient — 39,000 Btu/h rated heating at 5°F; cooling operation -13–122°F
- Wi-Fi Smart Kit built in — Cooper & Hunter app control; remote control included with each indoor unit; compatible with C&H 12V wall thermostat (sold separately)
- ETL listed, AHRI certified, Energy Star Cold Climate & NEEP listed