HVAC Mart
Menu
(844) 558-6388

Monday–Friday, 9:00 AM – 5:00 PM EST

Cooper & Hunter Olivia 12,000 BTU Single Zone Wall Mount, 115V, R454B - Ductless Mini Split Air Conditioner Heat Pump

SEER2 23.2HEATS down to −13°FCOOLS up to 122°FR454B

Cooper & Hunter7-Yr Warranty

$1,401.12
As low as $117/mo withaffirm
Product specifications
Voltage
115V
SEER
23.2
WiFi
Included
Zone
Single Zone
Type
Wall Mount
Freon
R454B
See full Tech Specs

Choose Your Configuration

*Installation Kit Option*: No Installation Kit

“No Installation Kit” ships the units only.

Save 10% on these accessories

  • ARMBRIDGE Mini Split Wall Mounting Bracket High Load Capacity Zinc, Vibration-Absorbing (Up to 550 lbs Each)ARMBRIDGE Mini Split Wall Mounting Bracket High Load Capacity Zinc, Vibration-Absorbing (Up to 550 lbs Each)-10%$49.00
  • ARMBRIDGE Heavy-Duty Mini Split Ground Stand, Zinc-Coated Brackets for 24,000–60,000 BTU Units Weatherproof Design, 330+ lbs CapacityARMBRIDGE Heavy-Duty Mini Split Ground Stand, Zinc-Coated Brackets for 24,000–60,000 BTU Units Weatherproof Design, 330+ lbs Capacity-10%$89.00
  • ARMBRIDGE 30 AMP Fusible Metallic Disconnect Box Durable Enclosed Disconnect for Residential and Light Commercial HVAC SystemsARMBRIDGE 30 AMP Fusible Metallic Disconnect Box Durable Enclosed Disconnect for Residential and Light Commercial HVAC Systems-10%$29.00
  • ARMBRIDGE Non-Metallic A/C Whip 3/4" x 6 ft – Pre-Wired Liquid tight Conduit with 8/2 & 10/1 Wires for HVAC & Air Conditioner Power ConnectionARMBRIDGE Non-Metallic A/C Whip 3/4" x 6 ft – Pre-Wired Liquid tight Conduit with 8/2 & 10/1 Wires for HVAC & Air Conditioner Power Connection-10%$34.00
1

FREE Delivery

Ships from the nearest of our three US warehouses, leaves in 1–2 business days. Shipping policy

Warranty Included
30-Day Returns

COOPER & HUNTER · OLIVIA

Built for year-round comfort

Indoor unit

System Specs

Cooling Capacity12,000 BTU/h
Heating Capacityup to 12,800 BTU/h
SEER223.2
EER212.5
Voltage115V
RefrigerantR454B
CompressorInverter
Climate Range-13–122°F / -13–75°F outdoor ambient
Sound Level (indoor)40.5/35/26.5 dB
Warranty7-Yr Compressor

Indoor Unit Specs

Unit Dimensions (WxDxH)Net / Gross WeightRemote Control
31.57 × 7.87 × 11.61 in19.84 / 26.01 lbRemote controller

Olivia Series Description

The Cooper & Hunter Olivia 12,000 BTU (1 Ton) wall mount mini split is a single-zone ductless air conditioner and heat pump on next-generation R454B refrigerant. The slim wall-mounted air handler suits bedrooms, living rooms, home offices, additions, and garages. With a 23.2 SEER2 inverter system on 115V, it cools and heats spaces up to approximately 550 sq ft and keeps heating in outdoor temperatures as low as -13°F. Wi-Fi control is built in.

6 Modes for Maximum Comfort

Engineered to adapt to every season, every room, every need.

Auto mode

Maintain a comfortable indoor temperature by automatically switching between heating and cooling as needed. Ideal for year-round use.

WHEREVER YOU ARE

Control your comfort, your way

  • Easy scheduling & timer
  • Multiple ways to control your comfort
  • Smart geo location
  • In-app support & assistance
  • Voice control
Easy scheduling & timer
Package contents

IN THE BOX

Everything included with this system


  1. Cooper & Hunter 12,000 BTU Outdoor Condenser, 115V, R454B - Single Zone Mini Split Air Conditioner Heat Pump
  2. Indoor Wall Mount — CH-R12OLVWM-115VI
7YEAR COMPRESSOR
WARRANTY

BACKED BY COOPER & HUNTER

Industry-leading protection on every unit

  • Compressor: 7-year coverage

    With product registration after professional installation.

  • Parts & components: 5-year coverage

    All major components and refrigerant circuit parts.

Technical Specifications

Outdoor Unit Specs— CH-RES12-115VO

Outdoor Unit — CH-RES12-115VO
ModelCH-RES12-115VO
Unit Dimensions (WxDxH)30.12 x 11.93 x 21.85 in
Net/Gross Weight64.59/70.11 lb
Packing Dimensions (WxDxH)34.92 x 13.27 x 24.02 in
Power Supply115V,60Hz,1Ph
Maximum Fuse Size20 A
Min. Circuit Ampacity18 A
Copper Line Size (Liquid/Gas)1/4"/3/8"
Noise Level53 dB
Airflow1,235.3 CFM
Dehumidification2.54 pt/h

Indoor Unit Specs— CH-R12OLVWM-115VI

Indoor Unit — CH-R12OLVWM-115VI
ModelCH-R12OLVWM-115VI
Unit Dimensions (WxDxH)31.57 x 7.87 x 11.61 in
Net/Gross Weight19.84/26.01 lb
Packing Dimensions (WxDxH)34.45 x 11.22 x 14.96 in
Power Supply115V, 1Ph, 60Hz
Maximum Fuse Size15 A
Min. Circuit Ampacity3 A
Copper Line Size (Liquid/Gas)1/4"/3/8"
Noise Level (Hi/Med/Lo)40.5/35/26.5 dB
Dehumidification2.54 pt/h
Drain Pipe Diameter5/8"
Controllerremote controller

System Specs

System
Cooling — Rated Capacity (Range)12,000 Btu/h (3,100–10,900)
Heating Capacity Range (47°F)up to 12,800 Btu/h
Rated Heating at 17°F (AHRI)10,200 Btu/h
SEER2 / EER223.2 / 12.5
HSPF4 / HSPF5 / COP (47°F)10.4 / 7.6 / 3.70
Outdoor Unit MCA / Max. Fuse18 A / 20 A
Indoor Unit MCA / Max. Fuse3 A / 15 A
Indoor Air Flow (Turbo/Hi/Mid/Lo/Silent)370.8 / 306.1 / 235.4 / 188.4 / 141.3 CFM
Indoor Noise Level (Turbo/Hi/Mid/Lo/Silent)44.0 / 40.5 / 35.0 / 26.5 / 17.5 dB(A)
Indoor Unit Dimensions (W×D×H)31.57 × 7.87 × 11.61 in
Indoor Unit Net / Gross Weight18.96 / 24.47 lbs
Outdoor Noise Level53.0 dB(A)
Outdoor Unit Dimensions (W×D×H)30.12 × 11.93 × 21.85 in
Outdoor Unit Net / Gross Weight64.59 / 70.11 lbs
Refrigerant Type / ChargeR454B / 33.51 oz
Pre-charged Line Length25 ft (add 0.16 oz per additional ft)
Line Set (Liquid / Gas)1/4" / 3/8"
Max. Pipe Length82 ft
Max. Elevation Difference49.2 ft
Operating Range — Cooling / Heating-13–122°F / -13–75°F outdoor ambient
Recommended Coverageup to 550 sq ft (guidance)

Series Comparison Table

Technical specifications for every model in the series — this product is one of them.

Indoor and Outdoor Hyper

SpecificationCH-R006MOLVWM-230VICH-R009MOLVWM-230VICH-R012MOLVWM-230VICH-R018MOLVWM-230VICH-R024MOLVWM-230VICH-R033HOLVWM-230VI
Power Supply Rated208/230, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60
Rated Capacity Btu/h6,0009,00012,00018,00023,00033,000
Minimum Circuit Ampacity (MCA) A333333
Max. Fuse A151515151515
Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) CFM294.3/225.4/176.8/141.3/NA382.6/293.1/194.2/153.0/NA382.6/293.1/194.2/153.0/NA759.3/530.4/419.1/382.6/NA759.3/586.5/419.1/382.6/NA829.6/716.6/592.7/447.3/NA
Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) dB(A)42.0/37.0/32.0/24.0/NA42.0/37.0/32.0/24.0/NA43.0/37.0/32.0/24.0/NA52.5/44.0/40.5/35.2/25.054.5/49.0/45.3/41.3/27.056.0/49.5/45.3/41.3/27.0
Dimension (WxDxH) inch28.7x7.87x11.8131.57x7.87x11.6131.57x7.87x11.6142.60x9.21x13.2742.60x9.21x13.2752.76x15.16x17.72
Packing (WxDxH) inch31.10x10.63x14.7634.45x11.22x14.9634.45x11.22x14.9645.47x12.40x16.3445.47x12.40x16.3452.76x15.16x17.72
Net/Gross Weight lbs.17.64/23.1518.96/24.2518.96/24.2530.42/39.6830.86/40.5667.16/17.72
Room temperature Cooling °F60~9060~9060~9060~9060~9060~90
Room temperature Heating °F32~8632~8632~8632~8632~8632~86
Liquid Side/Gas Side inch1/4" / 3/8"1/4" / 3/8"1/4" / 3/8"1/4" / 1/2"3/8" / 5/8"3/8" / 3/4"

Outdoor Model

SpecificationCH-RHP06F9-230VOCH-RHP09-230VOCH-RHP12-230VOCH-RHP18-230VOCH-RHP24-230VOCH-RHP33-230VO
Power Supply Rated V, Ph, Hz208/230, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60
Voltage Range V187-253187-253187-253187-253187-253187-253
Rated Capacity Range Btu/h2,500~11,5003,600~13,5003,600~13,5008,400~20,20016,000~24,50015,000~35,000
Cooling EER2 Btu/h16.015.013.213.012.511.7
SEER2 Btu/h25.326.024.021.722.319.5
Rated current A3.14.04.19.08.414.1
Heating at 47°F COP W/W3.803.633.633.543.053.22
HSPF414.612.510.510.813.310.5
HSPF511.210.18.08.89.68.3
Heating at 17°F (AHRI) Rated capacity Btu/h8,60012,80012,80019,80024,40030,200
Minimum Circuit Ampacity A1215151924.935
Max.Fuse (Outdoor Unit) A151515202540
Outdoor Air Flow (Max.) CFM1,235.31,470.61,470.61,764.72,235.32,235.3
Outdoor Noise Level (Sound Pressure) dB(A)53.056.056.059.061.063.5
Dimension (WxDxH) inch30.12x11.93x21.8531.69x12.99x21.8131.69x12.99x21.8135.04x13.46x26.5037.24x16.14x31.8937.44x19.09x34.84
Packing (WxDxH) inch34.92x13.27x24.0236.02x14.57x24.2136.02x14.57x24.2139.17x15.67x29.1342.91x19.69x34.8442.91x19.09x34.84
Net/Gross Weight lbs.62.17/67.6872.75/78.7072.75/78.7099.87/107.80130.29/141.31156.87/197.99
Refrigerant Type / Charge oz.R454B/32.45R454B/35.27R454B/35.27R454B/55.38R454B/63.49R454B/87.13
Refrigerant Precharge Length #252525252525
Additional Charge for Each ft. oz/ft0.160.160.160.160.320.32
Design Pressure PSIG550/340550/340550/340550/340550/340550/340
Refrigerant Piping Liquid Side/Gas Side inch1/4" / 3/8"1/4" / 3/8"1/4" / 3/8"1/4" / 1/2"3/8" / 5/8"3/8" / 3/4"
Max. Pipe Length ft.82828298.4164164
Max. Difference in Level ft.49.249.249.265.68282
Ambient Temperature Cooling °F-22~122-22~122-22~122-22~122-22~122-22~122
Heating °F-22~75-22~75-22~75-22~75-22~75-22~75
UL✓✓✓✓✓✓
AHRI✓✓✓✓✓✓
Energy Star✓✓✓✓✓✓
NEEP✓✓✓✓✓✓

Indoor and Outdoor Regular

SpecificationCH-R060LVWM-115VICH-R09OLVWM-115VICH-R120LVWM-115VICH-RO9MOLVWM-230VICH-R12MOLVWM-230VICH-R18MOLVWM-230VICH-R24MOLVWM-230VICH-R30MELVWM-230VICH-R36MELVWM-230VI
Power Supply Rated115V, 1, 60115V, 1, 60115V, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60
Rated Capacity Btu/h7,0009,00012,0009,00012,00018,00024,00030,00036,000
Minimum Circuit Ampacity (MCA) A333333333
Max. Fuse A333333333
Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) CFM370/340/265/174/-378/340/265/174/-378/340/265/174/-382/294/194/153/-382/294/194/153/-759/530/419/382/-759/586/419/382/-871/716/547/447/-871/716/547/447/-
Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) dB(A)44/40/35/26/-44/40/35/26/-44/40/35/26/-45/41/32/24/-45/41/32/24/-54/49/45/41/2754/49/45/41/2756/52/45/38/2256/52/45/38/22
Dimension (WxDxH) inch31.57x7.87x11.9531.57x7.87x11.9531.57x7.87x11.9531.57x7.87x11.9531.57x7.87x11.9545.47x12.01x16.3445.47x12.01x16.3449.57x11.14x14.2549.57x11.14x14.25
Packing (WxDxH) inch34.92x13.27x24.0234.92x13.27x24.0234.92x13.27x24.0234.92x13.27x24.0234.92x13.27x24.0242.91x19.09x34.8442.91x19.09x34.8442.91x19.09x34.8442.91x19.09x34.84
Net/Gross Weight lbs.18.64/22.0518.64/22.0518.64/22.0518.64/22.0518.64/22.0545.47/21.0645.47/21.0667.16/17.7267.16/17.72
Room temperature Cooling °F60~9060~9060~9060~9060~9060~9060~9060~9060~90
Room temperature Heating °F32~8632~8632~8632~8632~8632~8632~8632~8632~86
Liquid Side/Gas Side inch1/4" / 3/8"1/4" / 3/8"1/4" / 3/8"1/4" / 3/8"1/4" / 3/8"1/4" / 1/2"3/8" / 5/8"3/8" / 5/8"3/8" / 5/8"

Outdoor Model

SpecificationCH-RES06-115V0CH-RES09-115VOCH-RES12-115VOCH-RES09-230VOCH-RES12-230VOCH-RES18-230VOCH-RES24-230VOCH-REL30-230V0CH-REL36-230VO
Power Supply Rated V, Ph, Hz115, 1, 60115, 1, 60115, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60
Voltage Range V103.5-126.5103.5-126.5103.5-126.5187-253187-253187-253187-253187-253187-253
Rated Capacity Range Btu/h2,600~13,0002,600~13,0003,100~19,0002,600~13,7002,600~13,7003,600~20,0009,700~32,7006,800~33,9006,600~36,800
Cooling EER2 Btu/h6.96.910.06.96.911.011.011.011.0
SEER2 Btu/h15.015.015.015.015.015.015.015.015.0
Rated current A6.96.912.010.010.011.011.011.011.0
Heating at 47°F COP W/W24.524.523.224.623.122.319.522.319.5
HSPF44,500~12,8004,500~12,80045,00~12,8004,200~14,2004,100~14,4007,600~22,00011,300~32,70011,300~32,10011,400~44,000
HSPF57.67.610.33.64.36.213.412.613.6
Heating at 17°F (AHRI) Rated capacity Btu/h8.28.27.69.58.58.37.77.07.0
Minimum Circuit Ampacity A8,6008,90010,2008,9009,90014,50021,30021,50025,600
Max.Fuse (Outdoor Unit) A202018121820253035
Outdoor Air Flow (Max.) CFM1,235.31,235.31,235.31,235.31,235.31,794.72,235.32,235.32,205.0
Outdoor Noise Level (Sound Pressure) dB(A)53.053.053.053.053.054.060.060.060.0
Dimension (WxDxH) inch30.12x11.93x21.8530.12x11.93x21.8530.12x11.93x21.8530.12x11.93x21.8530.12x11.93x21.8535.04x13.46x26.5037.24x16.14x31.8937.24x16.14x31.8937.24x16.14x31.89
Packing (WxDxH) inch34.92x13.27x24.0234.92x13.27x24.0234.92x13.27x24.0234.92x13.27x24.0234.92x13.27x24.0239.17x15.67x29.1342.91x19.09x34.8442.91x19.09x34.8442.91x19.09x34.84
Net/Gross Weight lbs.64.59/70.1164.59/70.1164.59/70.1164.59/70.1164.59/70.1192.59/107.60128.17/132.28142.86/154.84150.35/160.27
Refrigerant Type / Charge oz.R454B/33.51R454B/33.51R454B/33.51R454B/32.45R454B/32.45R454B/47.97R454B/70.55R454B/84.66R454B/112.88
Refrigerant Precharge Length #252525252525252525
Additional Charge for Each ft. oz/ft0.160.160.160.160.160.320.320.320.32
Design Pressure PSIG550/340550/340550/340550/340550/340550/340550/340550/340550/340
Refrigerant Piping Liquid Side/Gas Side inch1/4" / 3/8"1/4" / 3/8"1/4" / 3/8"1/4" / 3/8"1/4" / 3/8"1/4" / 1/2"3/8" / 5/8"3/8" / 5/8"3/8" / 5/8"
Max. Pipe Length ft.828282828298.4164164213.2
Max. Difference in Level ft.49.249.249.249.249.265.6828298.4
Ambient Temperature Cooling °F-13~122-13~122-13~122-13~122-13~122-13~122-13~122-13~122-13~122
Heating °F-13~75-13~75-13~75-13~75-13~75-13~75-13~75-13~75-13~75
UL✓✓✓✓✓✓✓✓✓
AHRI✓✓✓✓✓✓✓✓✓
Energy Star✓✓✓✓✓✓✓✓✓
NEEP✓✓✓✓✓✓✓✓

Frequently asked questions.

What size mini split do I need for my room?

For optimal performance, the Cooper & Hunter Olivia 12,000 BTU mini split is suitable for spaces up to 550 sq ft. This capacity ensures adequate heating and cooling for average-sized rooms.

Can I install a mini split myself?

While some homeowners may attempt DIY installation, it's recommended to hire a professional for the Cooper & Hunter Olivia system to ensure proper setup, especially since it involves refrigerant handling. However, the installation process is straightforward for those with HVAC experience.

Does the mini split come pre-charged with refrigerant?

Yes, the Cooper & Hunter Olivia mini split comes pre-charged with R454B refrigerant for up to 25 ft of line set, making installation easier. This allows for a quick setup without the need for additional refrigerant filling.

What voltage does a mini split require?

The Cooper & Hunter Olivia operates on a standard 115V electrical supply, which is common in residential settings. This voltage requirement makes it compatible with most home electrical setups.

What warranty does Cooper & Hunter Olivia offer?

The Cooper & Hunter Olivia mini split features a solid warranty that includes a 5-year parts warranty and a 7-year compressor warranty, provided registration occurs within 30 days of purchase. This warranty offers peace of mind for your investment.

What SEER rating do I need for energy efficiency?

The Cooper & Hunter Olivia boasts an impressive SEER rating of 23.2, which is above the minimum efficiency standards set for mini splits. This high efficiency not only reduces energy costs but also qualifies for certain energy rebates and incentives.

Talk to a Sales Specialist

Not sure which system is right for your space? Our experts help with sizing and installation questions.

Mon – Fri, 8 AM – 5 PM (PST)

Get Support

Manufacturer Technical Support

Reach your brand's tech support team directly

Cooper & Hunter


(888) 201-2119

Olmo Comfort


(800) 977-0724

You may also like

The Cooper & Hunter Olivia 12,000 BTU (1 Ton) wall mount mini split is a single-zone ductless air conditioner and heat pump on next-generation R454B refrigerant. The slim wall-mounted air handler suits bedrooms, living rooms, home offices, additions, and garages. With a 23.2 SEER2 inverter system on 115V, it cools and heats spaces up to approximately 550 sq ft and keeps heating in outdoor temperatures as low as -13°F. Wi-Fi control is built in.

Key Features

  • 12,000 Btu/h rated cooling — inverter cooling range 3,100–10,900 Btu/h; heating capacity range up to 12,800 Btu/h at 47°F
  • 10,200 Btu/h AHRI rated heating at 17°F — certified low-ambient heat output
  • 23.2 SEER2 / 12.5 EER2 / 10.4 HSPF4 — current R454B-generation efficiency
  • Heats down to -13°F outdoor ambient; cooling operation -13–122°F
  • Auto-swing horizontal louvers with Turbo Mode, Follow Me mode, Sleep Mode, and Timer On/Off
  • Self-Cleaning and Eco modes (active on single-zone systems); 46°F freeze-protection function
  • Quiet: indoor unit from 17.5 dB(A) with Genius Core ultra-low 12Hz compressor speeds; outdoor unit 53.0 dB(A)
  • Wi-Fi Smart Kit built in — Cooper & Hunter app control; remote control included; compatible with C&H 12V wall thermostat (sold separately)
  • ETL listed, AHRI certified, Energy Star Cold Climate & NEEP listed

Cooper & Hunter Olivia Wall Mount (R454B) Lineup

Capacity Outdoor + Indoor Unit SEER2 Heats down to Coverage*
6,000 BTU Hyper Heat CH-RHP06F9-230VO + CH-R06MOLVWM-230VI 25.3 -22°F up to 300 sq ft
9,000 BTU CH-RES09-230VO + CH-R09MOLVWM-230VI 24.6 -13°F up to 400 sq ft
9,000 BTU Hyper Heat CH-RHP09-230VO + CH-R09MOLVWM-230VI 26.0 -22°F up to 400 sq ft
12,000 BTU CH-RES12-230VO + CH-R12MOLVWM-230VI 23.1 -13°F up to 550 sq ft
12,000 BTU (115V) CH-RES12-115VO + CH-R12OLVWM-115VI 23.2 -13°F up to 550 sq ft
12,000 BTU Hyper Heat CH-RHP12-230VO + CH-R12MOLVWM-230VI 24.0 -22°F up to 550 sq ft
18,000 BTU CH-RES18-230VO + CH-R18MOLVWM-230VI 24.0 -13°F up to 1,000 sq ft
18,000 BTU Hyper Heat CH-RHP18-230VO + CH-R18MOLVWM-230VI 21.7 -22°F up to 1,000 sq ft
24,000 BTU CH-RES24-230VO + CH-R24MOLVWM-230VI 23.5 -13°F up to 1,500 sq ft
24,000 BTU Hyper Heat CH-RHP24-230VO + CH-R24MOLVWM-230VI 22.3 -22°F up to 1,400 sq ft
30,000 BTU CH-REL30-230VO + CH-R30MELVWM-230VI 22.3 -13°F up to 1,800 sq ft
36,000 BTU CH-REL36-230VO + CH-R36MELVWM-230VI 19.5 -13°F up to 2,200 sq ft

*Coverage is sizing guidance; actual load depends on insulation, ceiling height, sun exposure, and climate.

Cart

Add $300.00 more for FREE shipping!

Your cart is empty

Looks like you haven't added anything yet.