HVAC Mart
Menu
(844) 558-6388

Monday–Friday, 9:00 AM – 5:00 PM EST

Cooper & Hunter Hyper Heat 12,000 BTU Single Zone Ceiling Cassette, 230V, R454B - Ductless Mini Split Air Conditioner Heat Pump

SEER2 21.1HEATS down to −22°FCOOLS up to 122°FR454B

Cooper & Hunter7-Yr WarrantySKU: CH-RHP12-230VO12CT

$2,026.42
As low as $169/mo withaffirm
Product specifications
Voltage
230V
SEER
21.1
WiFi
Included
Zone
Single Zone
Type
Ceiling Cassette
Freon
R454B
See full Tech Specs

Choose Your Configuration

Installation Kit: NO INSTALLATION KIT

“No Installation Kit” ships the units only.

Save 10% on these accessories

  • ARMBRIDGE Mini Split Wall Mounting Bracket High Load Capacity Zinc, Vibration-Absorbing (Up to 550 lbs Each)ARMBRIDGE Mini Split Wall Mounting Bracket High Load Capacity Zinc, Vibration-Absorbing (Up to 550 lbs Each)-10%$49.00
  • ARMBRIDGE Heavy-Duty Mini Split Ground Stand, Zinc-Coated Brackets for 24,000–60,000 BTU Units Weatherproof Design, 330+ lbs CapacityARMBRIDGE Heavy-Duty Mini Split Ground Stand, Zinc-Coated Brackets for 24,000–60,000 BTU Units Weatherproof Design, 330+ lbs Capacity-10%$89.00
  • ARMBRIDGE 30 AMP Fusible Metallic Disconnect Box Durable Enclosed Disconnect for Residential and Light Commercial HVAC SystemsARMBRIDGE 30 AMP Fusible Metallic Disconnect Box Durable Enclosed Disconnect for Residential and Light Commercial HVAC Systems-10%$29.00
  • ARMBRIDGE Non-Metallic A/C Whip 3/4" x 6 ft – Pre-Wired Liquid tight Conduit with 8/2 & 10/1 Wires for HVAC & Air Conditioner Power ConnectionARMBRIDGE Non-Metallic A/C Whip 3/4" x 6 ft – Pre-Wired Liquid tight Conduit with 8/2 & 10/1 Wires for HVAC & Air Conditioner Power Connection-10%$34.00
1

FREE Delivery

Ships from the nearest of our three US warehouses, leaves in 1–2 business days. Shipping policy

Warranty Included
30-Day Returns

COOPER & HUNTER · HYPER HEAT

Built for year-round comfort

Indoor unit

CH-RHP12-230VO12CT

System Specs

Cooling Capacity12,000 BTU/h
SEER222.2
EER212.5
Voltage230V
RefrigerantR454B
CompressorInverter
Climate Range-22–122°F / -22–75°F outdoor ambient
Sound Level (indoor)43.5/40.5/27.5 dB
Warranty7-Yr Compressor

Indoor Unit Specs

Unit Dimensions (WxDxH)Net / Gross WeightRemote Control
22.44 × 22.44 × 9.65 in35.27 / 41.89 lbWire controller + remote controller available

Hyper Heat Series Description

The Cooper & Hunter Hyper Heat 12,000 BTU (1 Ton) ceiling cassette is a single-zone flush-mount mini split air conditioner and heat pump on next-generation R454B refrigerant. The cassette recesses fully into the ceiling — only the low-profile panel stays visible — and a built-in condensate pump handles drainage. With a 22.2 SEER2 inverter system on 208/230V, it cools and heats spaces up to approximately 550 sq ft and keeps heating in outdoor temperatures as low as -22°F. Wi-Fi control is built in.

6 Modes for Maximum Comfort

Engineered to adapt to every season, every room, every need.

Auto mode

Maintain a comfortable indoor temperature by automatically switching between heating and cooling as needed. Ideal for year-round use.

WHEREVER YOU ARE

Control your comfort, your way

  • Easy scheduling & timer
  • Multiple ways to control your comfort
  • Smart geo location
  • In-app support & assistance
  • Voice control
Easy scheduling & timer
Package contents

IN THE BOX

Everything included with this system


  1. Cooper & Hunter Hyper 12,000 BTU Outdoor Condenser, 230V, R454B - Single Zone Mini Split Air Conditioner Heat Pump
  2. Indoor Ceiling Cassette — CH-RH12MCT
  3. Indoor Ceiling Cassette — CH-NPNL09-18CT
7YEAR COMPRESSOR
WARRANTY

BACKED BY COOPER & HUNTER

Industry-leading protection on every unit

  • Compressor: 7-year coverage

    With product registration after professional installation.

  • Parts & components: 5-year coverage

    All major components and refrigerant circuit parts.

Technical Specifications

Outdoor Unit Specs— CH-RHP12-230VO

Outdoor Unit — CH-RHP12-230VO
ModelCH-RHP12-230VO
Unit Dimensions (WxDxH)31.69 x 12.99 x 21.81 in
Net/Gross Weight72.75/78.70 lb
Packing Dimensions (WxDxH)36.02 x 14.57 x 24.21 in
Power Supply208-230V, 1Ph, 60Hz
Maximum Fuse Size15 A
Min. Circuit Ampacity15 A
Copper Line Size (Liquid/Gas)1/4"/3/8"
Noise Level56 dB
Airflow1,470.6 CFM
Dehumidification2.96 pt/h

Indoor Unit Specs— CH-RH12MCT

Indoor Unit — CH-RH12MCT
ModelCH-RH12MCT
Unit Dimensions (WxDxH)22.44 x 22.44 x 9.65 in
Net/Gross Weight35.27/41.89 lb
Packing Dimensions (WxDxH)28.15 x 25.20 x 11.61 in
Power Supply208-230V, 1Ph, 60Hz
Maximum Fuse Size15 A
Min. Circuit Ampacity3 A
Copper Line Size (Liquid/Gas)1/4"/3/8"
Noise Level (Hi/Med/Lo)43.5/40.5/27.5 dB
Dehumidification3.07 pt/h
Drain Pipe Diameter1"
Controllerwire controller + remote controller available

System Specs

System
Cooling — Rated Capacity (Range)12,000 Btu/h (3,800–15,100)
Heating — Rated Capacity (Range)12,000 Btu/h (5,300–16,200)
SEER2 / EER222.2 / 12.5
HSPF4 / HSPF5 / COP (47°F)11.6 / 8.9 / 3.70
Outdoor Unit MCA / Max. Fuse15 A / 15 A
Indoor Unit MCA / Max. Fuse3 A / 15 A
Indoor Air Flow (Turbo/Hi/Mid/Lo/Silent)418 / 365 / 306 / 194 / 147 CFM
Indoor Noise Level (Turbo/Hi/Mid/Lo/Silent)46.0 / 43.5 / 40.5 / 27.5 / 26.0 dB(A)
Indoor Cassette Dimensions (W×D×H)22.44 × 22.44 × 9.65 in (recessed body)
Decorative PanelCH-NPNL09-18CT — 25.47 × 25.47 × 1.97 in
Indoor Unit Net / Gross Weight35.3 / 41.9 lbs
Condensate RemovalBuilt-in drain pump; lift pipe up to 29.5 in above ceiling
Outdoor Noise Level57.0 dB(A)
Outdoor Unit Dimensions (W×D×H)31.69 × 12.99 × 21.81 in
Outdoor Unit Net / Gross Weight72.8 / 78.7 lbs
Refrigerant Type / ChargeR454B / 35.27 oz
Pre-charged Line Length25 ft (add 0.16 oz per additional ft)
Line Set (Liquid / Gas)1/4" / 3/8"
Max. Pipe Length82 ft
Max. Elevation Difference49.2 ft
Operating Range — Cooling / Heating-22–122°F / -22–75°F outdoor ambient
Recommended Coverageup to 550 sq ft (guidance)

Series Comparison Table

Technical specifications for every model in the series — this product is one of them.

System Type

SpecificationHyperRegular
Ceiling Cassette PROCH-RSH09-12MCT(Dip Switch for 9K)CH-RSH09-12MCT(Dip Switch for 12K)
Ceiling CassetteCH-RH09MCTCH-RH12MCT
Panel Model NumberCH-NPNL09-18CTCH-NPNL09-18CT
Power Supply (V,Ph,Hz)208/230,1,60208/230,1,60
Rated Capacity (Btu/h)9,00012,000
Minimum Circuit Ampacity (A)33
Max. Fuse (A)1515
Indoor Air Flow - Turbo/Hi/Mi/Lo (CFM)417.9/364.9/306.1/194.2/147.2417.9/364.9/306.1/194.2/147.2
Indoor Noise Level - Hi/Mi/Lo (dB(A))42.5/40/37.5/26/2446/43.5/40.5/27.5/26
Dimension (WxDxH) (inch)22.44x22.44x9.6522.44x22.44x9.65
Packing (WxDxH) (inch)28.15x25.20x11.6128.15x25.20x11.61
Net/Gross Weight (lbs.)35.27/41.8935.27/41.89
Cooling (°F)60~9060~90
Heating (°F)32~8632~86

System Type

SpecificationHyperRegular
Outdoor ModelCH-RHP09-230VOCH-RHP12-230VO
Power Supply (V,Ph,Hz)208/230,1,60208/230,1,60
Voltage Range (V)187-253187-253
Rated Capacity (range) (Btu/h)3,700~13,6003,800~15,100
Rated Current (A)4.84.6
EER2 (Btu/h)1412.5
SEER2 (Btu/h)22.622.2
Rated Capacity (range) (Btu/h)5,100~15,7005,300~16,200
Rated Current (A)3.34.4
COP (W/W)4.003.70
HSPF412.111.6
HSPF59.38.9
Minimum Circuit Ampacity (A)1515
Max. Fuse (Outdoor Unit) (A)1515
Outdoor Air Flow (Max.) (CFM)1,471.51,471.5
Outdoor Noise Level (Sound Pressure) (dB(A))5557
Dimension (WxDxH) (inch)31.69x12.99x21.8131.69x12.99x21.81
Packing (WxDxH) (inch)36.02x14.57x24.2136.02x14.57x24.21
Net/Gross Weight (lbs.)72.75/78.7072.75/78.70
Refrigerant Type/Charge (oz.)R454B/35.27R454B/35.27
Refrigerant Precharge Length (ft.)2525
Additional Charge for Each ft. (oz/ft)0.160.16
Design Pressure (PSIG)550/340550/340
Refrigerant Piping Liquid Side/Gas Side (inch)1/4"/3/8"1/4"/3/8"
Max. Pipe Length (ft.)82.0082.00
Max. Difference in Level (ft.)49.2049.20
Cooling (°F)-22~122-22~122
Heating (°F)22~75-22~75

Frequently asked questions.

What's included in this system?

A complete single-zone system: the indoor unit and its matching outdoor condenser. Choose a line-set kit length at checkout, or supply your own.

What size room does it suit?

It is rated at 12,000 BTU — size it to your room’s square footage and insulation for the best match.

Does it heat as well as cool?

Yes — it is an inverter heat pump that both cools and heats down to -22°F outdoor ambient (Hyper Heat). See the specifications for this model’s heating range.

What refrigerant does it use?

R454B. The system ships factory pre-charged; a licensed installer adjusts the charge for your line length.

Who should install it?

A licensed HVAC professional — required for the refrigerant, electrical, and startup work, and to keep the manufacturer warranty valid. Many customers buy the equipment here and hire a local installer.

What warranty does it come with?

Cooper & Hunter backs it with a 7-year compressor and 5-year parts limited warranty (with professional installation and registration).

Talk to a Sales Specialist

Not sure which system is right for your space? Our experts help with sizing and installation questions.

Mon – Fri, 8 AM – 5 PM (PST)

Get Support

Manufacturer Technical Support

Reach your brand's tech support team directly

Cooper & Hunter


(888) 201-2119

Olmo Comfort


(800) 977-0724

You may also like

The Cooper & Hunter Hyper Heat 12,000 BTU (1 Ton) ceiling cassette is a single-zone flush-mount mini split air conditioner and heat pump on next-generation R454B refrigerant. The cassette recesses fully into the ceiling — only the low-profile panel stays visible — and a built-in condensate pump handles drainage. With a 22.2 SEER2 inverter system on 208/230V, it cools and heats spaces up to approximately 550 sq ft and keeps heating in outdoor temperatures as low as -22°F. Wi-Fi control is built in.

Key Features

  • 12,000 Btu/h cooling / 12,000 Btu/h heating — inverter range 3,800–15,100 cooling, 5,300–16,200 heating
  • 22.2 SEER2 / 12.5 EER2 / 11.6 HSPF4 — current R454B-generation efficiency
  • Hyper Heat: heats down to -22°F outdoor ambient; cooling operation -22–122°F
  • Built-in condensate pump — drain lift pipe up to 29.5 in above the ceiling board
  • Humidity sensor (active on single-zone systems) and washable fresh-air filter
  • Quiet: indoor unit from 26.0 dB(A); outdoor unit 57.0 dB(A)
  • Wi-Fi Smart Kit built in — Cooper & Hunter app control; IR remote and 12V wall thermostat included (thermostat connection enables smart features)
  • ETL listed, AHRI certified, Energy Star Cold Climate & NEEP listed

Cooper & Hunter Ceiling Cassette (R454B) Lineup

Capacity Outdoor + Indoor Cassette SEER2 Heats down to Coverage*
9,000 BTU CH-RES09-230VO + CH-RH09MCT 21.6 -13°F up to 400 sq ft
9,000 BTU Hyper Heat CH-RHP09-230VO + CH-RH09MCT 22.6 -22°F up to 400 sq ft
12,000 BTU CH-RES12-230VO + CH-RH12MCT 21.1 -13°F up to 550 sq ft
12,000 BTU Hyper Heat CH-RHP12-230VO + CH-RH12MCT 22.2 -22°F up to 550 sq ft
18,000 BTU CH-RES18-230VO + CH-RH18MCT 20.7 -13°F up to 900 sq ft
18,000 BTU Hyper Heat CH-RHP18-230VO + CH-RH18MCT 20.0 -22°F up to 850 sq ft
24,000 BTU CH-RES24-230VO + CH-RH24MCT 22.0 -13°F up to 1,500 sq ft
24,000 BTU Hyper Heat CH-RHP24-230VO + CH-RH24MCT 20.7 -22°F up to 1,400 sq ft
36,000 BTU LC CH-R36LCU-230VO + CH-RH36LCCT 20.0 -13°F up to 2,200 sq ft
36,000 BTU Hyper Heat LC CH-RHP36LCU-230VO + CH-RH36LCCT 21.2 -22°F up to 2,200 sq ft
48,000 BTU LC CH-R48LCU-230VO + CH-RH48LCCT 19.0 -13°F up to 3,000 sq ft
48,000 BTU Hyper Heat LC CH-RHP48LCU-230VO + CH-RH48LCCT 18.0 -22°F up to 3,000 sq ft

*Coverage is sizing guidance; actual load depends on insulation, ceiling height, sun exposure, and climate. LC = Light Commercial.

Cart

Add $300.00 more for FREE shipping!

Your cart is empty

Looks like you haven't added anything yet.