Cooper & Hunter 60,000 BTU Single Zone Light Commercial Slim Duct, 230V, R454B - Ductless Mini Split Air Conditioner Heat Pump
Cooper & Hunter7-Yr WarrantySKU: CH-R60LCU-230VO60DT
Product specifications
- Voltage
- 230V
- SEER
- 18.0
- WiFi
- Included
- Zone
- Single Zone
- Type
- Concealed Duct
- Freon
R454B
Choose Your Configuration
“No Installation Kit” ships the units only.
Size — match your room area
Save 10% on these accessories
ARMBRIDGE Mini Split Wall Mounting Bracket High Load Capacity Zinc, Vibration-Absorbing (Up to 550 lbs Each)-10%$49.00
ARMBRIDGE Heavy-Duty Mini Split Ground Stand, Zinc-Coated Brackets for 24,000–60,000 BTU Units Weatherproof Design, 330+ lbs Capacity-10%$89.00
ARMBRIDGE 30 AMP Fusible Metallic Disconnect Box Durable Enclosed Disconnect for Residential and Light Commercial HVAC Systems-10%$29.00
ARMBRIDGE Non-Metallic A/C Whip 3/4" x 6 ft – Pre-Wired Liquid tight Conduit with 8/2 & 10/1 Wires for HVAC & Air Conditioner Power Connection-10%$34.00
FREE Delivery
Ships from the nearest of our three US warehouses, leaves in 1–2 business days. Shipping policy
COOPER & HUNTER · STANDARD
Built for year-round comfort
CH-R60LCU-230VO60DT
System Specs
| Cooling Capacity | 58,000 BTU/h |
|---|---|
| SEER2 | 17.0 |
| EER2 | 10.0 |
| Voltage | 230V |
| Refrigerant | R454B |
| Compressor | Inverter |
|---|---|
| Climate Range | −13–122°F / −13–75°F outdoor ambient |
| Sound Level (indoor) | 52/48/42 dB |
| Warranty | 7-Yr Compressor |
Indoor Unit Specs
| Unit Dimensions (WxDxH) | Net / Gross Weight | Remote Control |
|---|---|---|
| 55.12 × 31.50 × 14.96 in | 161.38 / 178.13 lb | Wire controller + remote controller available |
Product Description
The Cooper & Hunter 60,000 BTU (5 Ton) single-zone Light Commercial slim duct mini split is a concealed-duct air conditioner and heat pump running on next-generation R454B refrigerant. The low-profile ducted air handler hides above a ceiling or in a soffit and distributes air through short duct runs — central-air comfort with mini-split efficiency ( 17.0 SEER2, 208/230V). Heating operation continues down to −13°F outdoor ambient.
6 Modes for Maximum Comfort
Engineered to adapt to every season, every room, every need.
Maintain a comfortable indoor temperature by automatically switching between heating and cooling as needed. Ideal for year-round use.
WHEREVER YOU ARE
Control your comfort, your way
- Easy scheduling & timer
- Multiple ways to control your comfort
- Smart geo location
- In-app support & assistance
- Voice control

IN THE BOX
Everything included with this system
- Cooper & Hunter 60,000 BTU Outdoor Condenser, 230V, R454B - Single Zone Mini Split Air Conditioner Heat Pump
- Indoor Concealed Duct — CH-RS60LCDT-HS
WARRANTY
BACKED BY COOPER & HUNTER
Industry-leading protection on every unit
Compressor: 7-year coverage
With product registration after professional installation.
Parts & components: 5-year coverage
All major components and refrigerant circuit parts.
Technical Specifications
Outdoor Unit Specs— CH-R60LCU-230VO
| Model | CH-R60LCU-230VO |
|---|---|
| Unit Dimensions (WxDxH) | 37.48 x 16.34 x 52.48 in |
| Net/Gross Weight | 209.44/240.08 lb |
| Packing Dimensions (WxDxH) | 43.11 x 19.49 x 58.27 in |
| Power Supply | 208-230V, 1Ph, 60Hz |
| Maximum Fuse Size | 45 A |
| Min. Circuit Ampacity | 42 A |
| Copper Line Size (Liquid/Gas) | 3/8"/3/4" |
| Noise Level | 63.5 dB |
| Airflow | 4,237,9 CFM |
| Dehumidification | 15.81 pt/h |
Indoor Unit Specs— CH-RS60LCDT-HS
| Model | CH-RS60LCDT-HS |
|---|---|
| Unit Dimensions (WxDxH) | 55.12 x 31.50 x 14.96 in |
| Net/Gross Weight | 161.38/178.13 lb |
| Packing Dimensions (WxDxH) | 62.99 x 36.02 x 17.52 in |
| Power Supply | 208-230V, 1Ph, 60Hz |
| Maximum Fuse Size | 15 A |
| Min. Circuit Ampacity | 5 A |
| Copper Line Size (Liquid/Gas) | 3/8"/3/4" |
| Noise Level (Hi/Med/Lo) | 52/48/42 dB |
| Dehumidification | 7.67 pt/h |
| Filter Dimensions | 24.80x12.60 in |
| Drain Pipe Diameter | 1" |
| Controller | wire controller + remote controller available |
System Specs
| Cooling — Rated Capacity (Range) | 58,000 Btu/h (14,600–63,000) |
|---|---|
| Heating — Rated Capacity (Range) | 60,000 Btu/h (11,800–67,000) |
| SEER2 / EER2 | 17.0 / 10.0 |
| HSPF4 / HSPF5 / COP (47°F) | 9.7 / 7.6 / 3.70 |
| Rated Current (Cooling) | 25.6 A |
| Minimum Circuit Ampacity — Outdoor / Indoor | 42 A / 3 A |
| Max. Fuse — Outdoor / Indoor | 45 A / 15 A |
| External Static Pressure (ESP) | 0–0.8 in.WG (high static, 8 fan curves) |
| Indoor Air Flow (Turbo/Hi/Mid/Lo) | 2,001 / 1,707 / 1,413 / 1,118 CFM |
| Indoor Noise Level | 52 / 48 / 43 / 42 dB(A) (Hi/Mid/Lo/Silent) |
| Indoor Unit Dimensions (W×D×H) | 55.12 × 31.50 × 14.96 in |
| Indoor Unit Net Weight | 161.4 lbs |
| Outdoor Air Flow (Max.) | 4,238 CFM |
| Outdoor Noise Level | 64.0 dB(A) |
| Outdoor Unit Dimensions (W×D×H) | 37.48 × 16.34 × 52.48 in |
| Outdoor Unit Net / Gross Weight | 209.4 / 240.1 lbs |
| Refrigerant Type / Charge | R454B / 144.62 oz |
| Pre-charged Line Length | 25 ft (add 0.32 oz per additional ft) |
| Line Set (Liquid / Gas) | 3/8" / 3/4" |
| Max. Pipe Length | 246 ft |
| Max. Elevation Difference | 98.4 ft |
| Operating Range — Cooling / Heating | −13–122°F / −13–75°F outdoor ambient |
| Drain Pump | Built-in |
Frequently asked questions.
How many rooms can the Cooper & Hunter 60,000 BTU mini split cool?
The Cooper & Hunter 60,000 BTU Single Zone Light Commercial Slim Duct mini split can effectively cover up to 2,500 square feet, making it suitable for multiple rooms depending on their size and layout.
Can I mix BTU sizes when installing a mini split system?
While you can mix BTU sizes in a multi-zone setup, it's essential to ensure that the total BTU does not exceed the capacity of the outdoor unit, such as the Cooper & Hunter's 60,000 BTU model which operates efficiently at a SEER rating of 18.0.
Do all zones run simultaneously in a multi-zone mini split system?
In a multi-zone system, such as those offered by Cooper & Hunter, zones can be controlled independently, allowing you to heat or cool different areas without all zones running at the same time.
What is the efficiency advantage of using a Cooper & Hunter mini split vs multiple single-zone units?
Using the Cooper & Hunter 60,000 BTU mini split, which boasts an 18.0 SEER rating, can be more energy-efficient compared to several single-zone units, as it minimizes energy loss and optimizes performance across larger spaces.
What warranty does the Cooper & Hunter mini split offer?
The Cooper & Hunter mini split system comes with a 5-year parts warranty and a 7-year compressor warranty, provided you register the product within 30 days of purchase.
Does the Cooper & Hunter mini split come pre-charged with refrigerant?
Yes, the Cooper & Hunter 60,000 BTU mini split is pre-charged with R454B refrigerant for up to 25 ft of line set, allowing for a straightforward installation process.
Manufacturer Technical Support
Reach your brand's tech support team directly
You may also like
- R454BSEER2 16.4HEATS down to −13°FCOOLS up to 122°F
7-Yr Warranty
Cooper & HunterCooper & Hunter 36,000 BTU Single Zone Light Commercial Ceiling Cassette, 230V, R454B - Ductless Mini Split Air Conditioner Heat PumpFree Shipping
- R454BSEER2 20.0HEATS down to −13°FCOOLS up to 122°F
7-Yr Warranty
Cooper & HunterCooper & Hunter 36,000 BTU Single Zone Light Commercial Universal Floor/Ceiling, 230V, R454B - Ductless Mini Split Air Conditioner Heat PumpFree Shipping
- R454BSEER2 16.5HEATS down to −13°FCOOLS up to 122°F
7-Yr Warranty
Cooper & HunterCooper & Hunter 36,000 BTU Single Zone Light Commercial Slim Duct, 230V, R454B - Ductless Mini Split Air Conditioner Heat PumpFree Shipping
- R454BSEER2 21.2HEATS down to −22°FCOOLS up to 122°F
7-Yr Warranty
Cooper & HunterCooper & Hunter 36,000 BTU Single Zone Light Commercial Ceiling Cassette, 230V, R454B - Ductless Mini Split Air Conditioner Heat PumpFree Shipping
The Cooper & Hunter 60,000 BTU (5 Ton) single-zone Light Commercial slim duct mini split is a concealed-duct air conditioner and heat pump running on next-generation R454B refrigerant. The low-profile ducted air handler hides above a ceiling or in a soffit and distributes air through short duct runs — central-air comfort with mini-split efficiency (17.0 SEER2, 208/230V). Heating operation continues down to −13°F outdoor ambient.
Key Features
- 58,000 BTU cooling / 60,000 BTU heating — inverter range 14,600–63,000 Btu/h cooling, 11,800–67,000 Btu/h heating
- 17.0 SEER2 / 10.0 EER2 / 9.7 HSPF4 — current R454B-generation ratings
- Concealed installation: external static pressure 0–0.8 in.WG (high static, 8 fan curves) — supports real duct runs, grilles and filters
- Heats down to −13°F, cooling operation −13–122°F outdoor ambient
- Built-in condensate drain pump — simplifies above-ceiling installation
- Wired wall thermostat and IR remote included; Smart Kit built in (Wi-Fi via wall thermostat connection)
- 208/230V, 1Ph, 60Hz — MCA 42 A, max fuse 45 A
- ETL listed, AHRI certified, NEEP listed
Cooper & Hunter Single-Zone Slim Duct (R454B) Lineup
| Capacity | Model (Indoor + Outdoor) | SEER2 |
| 9,000 BTU | CH-RS06-12MDT-MS + CH-RES09-230VO | 19.5 |
| 12,000 BTU | CH-RS06-12MDT-MS + CH-RES12-230VO | 19.0 |
| 18,000 BTU | CH-RS18MDT-MS + CH-RES18-230VO | 20.0 |
| 24,000 BTU | CH-RS24MDT-HS + CH-RES24-230VO | 19.0 |
| 36,000 BTU | CH-RS36LCDT-HS + CH-R36LCU-230VO | 18.7 |
| 48,000 BTU | CH-RS48LCDT-HS + CH-R48LCU-230VO | 17.1 |
| 60,000 BTU | CH-RS60LCDT-HS + CH-R60LCU-230VO | 17.0 |