Cooper & Hunter 60,000 BTU 230V Ductless Mini Split AC R454B Light Commercial Universal Floor/Ceiling Console Heat Pump
Cooper & Hunter7-Yr WarrantySKU: CH-R60LCU-230VO60FC
Product specifications
- Voltage
- 230V
- SEER
- 19.5
- WiFi
- Included
- Zone
- Single Zone
- Type
- Universal Floor/Ceiling
- Freon
R454B
Choose Your Configuration
“No Installation Kit” ships the units only.
Save 10% on these accessories
ARMBRIDGE Mini Split Wall Mounting Bracket High Load Capacity Zinc, Vibration-Absorbing (Up to 550 lbs Each)-10%$49.00
ARMBRIDGE Heavy-Duty Mini Split Ground Stand, Zinc-Coated Brackets for 24,000–60,000 BTU Units Weatherproof Design, 330+ lbs Capacity-10%$89.00
ARMBRIDGE 30 AMP Fusible Metallic Disconnect Box Durable Enclosed Disconnect for Residential and Light Commercial HVAC Systems-10%$29.00
ARMBRIDGE Non-Metallic A/C Whip 3/4" x 6 ft – Pre-Wired Liquid tight Conduit with 8/2 & 10/1 Wires for HVAC & Air Conditioner Power Connection-10%$34.00
FREE Delivery
Ships from the nearest of our three US warehouses, leaves in 1–2 business days. Shipping policy
COOPER & HUNTER · STANDARD
Built for year-round comfort
CH-R60LCU-230VO60FC
System Specs
| Cooling Capacity | 54,000 BTU/h |
|---|---|
| SEER2 | 19.5 |
| EER2 | 9.5 |
| Voltage | 230V |
| Refrigerant | R454B |
| Compressor | Inverter |
|---|---|
| Climate Range | -13–122°F / -13–75°F outdoor ambient |
| Sound Level (indoor) | 54.5 / 49.5 / 41.5 / 38.5 dB(A) |
| Warranty | 7-Yr Compressor |
Indoor Unit Specs
| Unit Dimensions (WxDxH) | Net / Gross Weight | Remote Control |
|---|---|---|
| 64.96 × 26.57 × 9.25 in | 95.24 / 111.33 lb | Remote controller |
Product Description
The Cooper & Hunter 60,000 BTU (5 Ton) light commercial universal floor/ceiling unit is a single-zone mini split air conditioner and heat pump on next-generation R454B refrigerant that installs two ways: suspended flat under the ceiling or as a console at the base of the wall — no ductwork either way. With a 19.5 SEER2 inverter system on 208/230V, it cools and heats open spaces up to approximately 3,300 sq ft and keeps heating in outdoor temperatures as low as -13°F (rated 54,000 Btu/h cooling / 60,000 Btu/h heating). Wi-Fi control is built in.
6 Modes for Maximum Comfort
Engineered to adapt to every season, every room, every need.
Maintain a comfortable indoor temperature by automatically switching between heating and cooling as needed. Ideal for year-round use.
WHEREVER YOU ARE
Control your comfort, your way
- Easy scheduling & timer
- Multiple ways to control your comfort
- Smart geo location
- In-app support & assistance
- Voice control

IN THE BOX
Everything included with this system
- Cooper & Hunter 60,000 BTU Outdoor Condenser, 230V, R454B - Single Zone Mini Split Air Conditioner Heat Pump
- Indoor Universal Floor/Ceiling — CH-RSH60LCFC
WARRANTY
BACKED BY COOPER & HUNTER
Industry-leading protection on every unit
Compressor: 7-year coverage
With product registration after professional installation.
Parts & components: 5-year coverage
All major components and refrigerant circuit parts.
Technical Specifications
Outdoor Unit Specs— CH-R60LCU-230VO
| Model | CH-R60LCU-230VO |
|---|---|
| Unit Dimensions (WxDxH) | 37.48 x 16.34 x 52.48 in |
| Net/Gross Weight | 209.44/240.08 lb |
| Packing Dimensions (WxDxH) | 43.11 x 19.49 x 58.27 in |
| Power Supply | 208-230V, 1Ph, 60Hz |
| Maximum Fuse Size | 45 A |
| Min. Circuit Ampacity | 42 A |
| Copper Line Size (Liquid/Gas) | 3/8"/3/4" |
| Noise Level | 63.5 dB |
| Airflow | 4,237,9 CFM |
| Dehumidification | 15.81 pt/h |
Indoor Unit Specs— CH-RSH60LCFC
| Model | CH-RSH60LCFC |
|---|---|
| Unit Dimensions (WxDxH) | 64.96 x 26.57 x 9.25 in |
| Net/Gross Weight | 95.24/111.33 lb |
| Packing Dimensions (WxDxH) | 67.91 x 29.72 x 12.52 in |
| Power Supply | 208-230V, 1Ph, 60Hz |
| Maximum Fuse Size | 15 A |
| Min. Circuit Ampacity | 3 A |
| Copper Line Size (Liquid/Gas) | 3/8"/3/4" |
| Noise Level (Hi/Med/Lo) | 54.5/49/42 dB |
| Dehumidification | 15.14 pt/h |
| Drain Pipe Diameter | 1" |
| Controller | remote controller |
System Specs
| Cooling — Rated Capacity (Range) | 54,000 Btu/h (15,000–54,500) |
|---|---|
| Heating — Rated Capacity (Range) | 60,000 Btu/h (20,200–60,000) |
| SEER2 / EER2 | 19.5 / 9.5 |
| HSPF4 / HSPF5 / COP (47°F) | 9.5 / 7.2 / 3.05 |
| Outdoor Unit MCA / Max. Fuse | 42 A / 45 A |
| Indoor Unit MCA / Max. Fuse | up to 3 A / 15 A |
| Indoor Air Flow (Turbo/Hi/Mid/Lo/Silent) | 1366 / 1236 / 1118 / 883 / 777 CFM |
| Indoor Noise Level (Hi/Mid/Lo/Silent) | 54.5 / 49.5 / 41.5 / 38.5 dB(A) |
| Indoor Unit Dimensions (W×D×H) | 64.96 × 26.57 × 9.25 in |
| Indoor Unit Net / Gross Weight | 95.2 / 111.3 lbs |
| Outdoor Noise Level | 63.5 dB(A) |
| Outdoor Unit Dimensions (W×D×H) | 37.48 × 16.34 × 52.48 in |
| Outdoor Unit Net / Gross Weight | 209.4 / 240.1 lbs |
| Refrigerant Type / Charge | R454B / 144.62 oz |
| Pre-charged Line Length | 25 ft (add 0.32 oz per additional ft) |
| Line Set (Liquid / Gas) | 3/8" / 3/4" |
| Max. Pipe Length | 246 ft |
| Max. Elevation Difference | 98.4 ft |
| Operating Range — Cooling / Heating | -13–122°F / -13–75°F outdoor ambient |
| Recommended Coverage | up to 3,300 sq ft (guidance) |
Series Comparison Table
Technical specifications for every model in the series — this product is one of them.
Indoor Model
| Specification | Model Numbers |
|---|---|
| CH-RSH18MFC | CH-RSH24MFC |
| Rated (V, Ph, Hz) | 208/230,1,60 |
| Cooling (Btu/h) | 17,000 |
| Heating (Btu/h) | 19,000 |
| Minimum Circuit Ampacity (MCA) (A) | 1.9 |
| Max. Fuse (A) | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) (CFM) | 576.8/547.4/465.6/420.8/INA |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) (dB(A)) | 45/42.5/39.5/30.5/29 |
| Dimension (W×D×H) (inch) | 42.05×26.57×9.25 |
| Packing (W×D×H) (inch) | 45.08×29.72×12.52 |
| Net/Gross Weight (lbs.) | 58.42/70.55 |
| Cooling (°F) | 60~90 |
| Heating (°F) | 32~86 |
| Liquid Side/Gas Side (inch) | 1/4"/1/2" |
Specification
| Specification | Outdoor Model |
|---|---|
| CH-RHP18-230V0 | CH-RHP24-230V0 |
| Rated (V, Ph, Hz) | 208/230,1,60 |
| Voltage Range (V) | 187-253 |
| Rated Capacity Range (Btu/h) | 7,400~19,200 |
| Rated Current (A) | 8.7 |
| EER2 (Btu/h) | 12.5 |
| SEER2 (Btu/h) | 20.4 |
| Rated Capacity Range (Btu/h) | 8,300~20,700 |
| Rated Current (A) | 11 |
| COP (W/W) | 3.07 |
| HSPF4 | 10.3 |
| HSPF5 | 8.2 |
| Minimum Circuit Ampacity (A) | 19 |
| Max.Fuse (Outdoor Unit) (A) | 20 |
| Outdoor Air Flow (Max.) (CFM) | 1,765.8 |
| Outdoor Noise Level (Sound Pressure) (dB(A)) | 58 |
| Dimension (W×D×H) (inch) | 35.04×13.46×26.50 |
| Packing (W×D×H) (inch) | 39.17×15.67×29.13 |
| Net/Gross Weight (lbs.) | 99.87/107.80 |
| Refrigerant Type / Charge (oz.) | R454B/55.38 |
| Refrigerant Precharge Length (ft.) | 25 |
| Additional Charge for Each ft. (oz/ft) | 0.16 |
| Design Pressure (PSIG) | 550/340 |
| Refrigerant Piping Liquid Side/Gas Side (inch) | 1/4"×1/2" |
| Max. Pipe Length (ft.) | 98.42 |
| Max. Difference in Level (ft.) | 65.60 |
| Ambient Temperature - Cooling (°F) | -22~122 |
| Ambient Temperature - Heating (°F) | -22~75 |
| ETL | ✔ |
| AHRI | ✔ |
| Energy Star | ✔ |
| NEEP | ✔ |
Specification
| Specification | CH-RSH18MFC | CH-RSH24MFC | CH-RSH36LCFC | CH-RSH48LCFC | CH-RSH60LCFC |
|---|---|---|---|---|---|
| Power Supply - Rated (V, Ph, Hz) | 208/230,1,60 | 208/230,1,60 | 208/230,1,60 | 208/230,1,60 | 208/230,1,60 |
| Cooling Capacity (Btu/h) | 18,000 | 24,000 | 36,000 | 48,000 | 54,000 |
| Heating Capacity (Btu/h) | 18,000 | 24,400 | 38,000 | 50,000 | 60,000 |
| Minimum Circuit Ampacity (A) | 1.9 | 2.5 | 3 | 3 | 3 |
| Max. Fuse (A) | 15 | 15 | 15 | 15 | 15 |
| Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) (CFM) | 576.8/547.4/485.6/420.8/N\A | 735.8/706.3/606.3/453.2/376.7 | 1224.3/1088.9/988.8/765.2/653.3 | 1353.8/1236.1/1083.0/800.5/665.1 | 1365.6/1236.1/1118.3/882.9/777.0 |
| Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) (dB(A)) | N\A/43.0/40.0/32.0/29.0 | 51.5/49/45/34/29 | 50.5/49/44.5/37/33 | N\A/53/49/39/34.5 | N\A/54.5/49.5/41.5/38.5 |
| Dimension (W×D×H) (inch) | 42.05×26.57×9.25 | 42.05×26.57×9.25 | 64.96×26.57×9.25 | 64.96×26.57×9.25 | 64.96×26.57×9.25 |
| Packing (W×D×H) (inch) | 45.08×29.72×12.52 | 45.08×29.72×12.52 | 67.91×29.72×12.52 | 67.91×29.72×12.52 | 67.91×29.72×12.52 |
| Net/Gross Weight (lbs.) | 58.42/70.55 | 61.29/73.19 | 88.85/104.94 | 89.07/105.16 | 95.24/111.33 |
| Operating Temperature - Cooling (°F) | 60~90 | 60~90 | 60~90 | 60~90 | 60~90 |
| Operating Temperature - Heating (°F) | 32~86 | 32~86 | 32~86 | 32~86 | 32~86 |
| Refrigerant Piping (Liquid Side/Gas Side) (inch) | 1/4"×1/2" | 3/8"×5/8" | 3/8"×3/4" | 3/8"×3/4" | 3/8"×3/4" |
Specification
| Specification | CH-RES18-230V0 | CH-RES24-230V0 | CH-R36LCU-230V0 | CH-R48LCU-230V0 | CH-R60LCU-230V0 |
|---|---|---|---|---|---|
| Power Supply - Rated (V, Ph, Hz) | 208/230,1,60 | 208/230,1,60 | 208/230,1,60 | 208/230,1,60 | 208/230,1,60 |
| Power Supply - Voltage Range (V) | 187-253 | 187-253 | 187-253 | 187-253 | 187-253 |
| Cooling - Rated Capacity Range (Btu/h) | 7,000~19,300 | 11,100~29,000 | 7,300~39,500 | 10,100~50,000 | 15,000~54,500 |
| Cooling - Rated Current (A) | 6.4 | 8.6 | 15.3 | 22 | 24.6 |
| Cooling - EER (Btu/h) | 12.5 | 12.2 | 10.1 | 9.5 | 9.5 |
| Cooling - SEER (Btu/h) | 23.3 | 21.1 | 20 | 19.8 | 19.5 |
| Heating - Rated Capacity Range (Btu/h) | 7,200~22,200 | 11,800~32,600 | 14,100~40,400 | 15,800~59,100 | 20,200~60,000 |
| Heating - Rated Current (A) | 7.2 | 10.4 | 14.3 | 22.6 | 26.2 |
| Heating - COP (W/W) | 3.30 | 2.99 | 3.34 | 2.82 | 3.05 |
| Heating - HSPF4 | 10.4 | 11.1 | 10 | 10.2 | 9.5 |
| Heating - HSPF5 | 8.0 | 8.4 | 7.7 | 7.8 | 7.2 |
| Minimum Circuit Ampacity (A) | 18 | 24 | 33 | 39 | 42 |
| Max.Fuse (Outdoor Unit) (A) | 20 | 25 | 35 | 40 | 45 |
| Outdoor Air Flow (Max.) (CFM) | 1,765.8 | 2,236.7 | 2,413.3 | 4,237.9 | 4,237.9 |
| Outdoor Noise Level (dB(A)) | 57 | 59 | 64 | 62.5 | 63.5 |
| Dimension (W×D×H) (inch) | 35.04×13.46×26.50 | 37.24×16.14×31.89 | 37.24×16.14×31.89 | 37.48×16.34×52.48 | 37.48×16.34×52.48 |
| Packing (W×D×H) (inch) | 39.17×15.67×29.13 | 42.91×19.69×34.84 | 42.91×19.68×34.84 | 43.11×19.49×57.48 | 43.11×19.49×58.27 |
| Net/Gross Weight (lbs.) | 42.0/45.5 | 55.4/60.0 | 152.34/162.48 | 208.78/239.86 | 209.44/240.08 |
| Refrigerant Type / Charge (oz.) | R454B/47.97 | R454B/70.55 | R454B/91.71 | R454B/126.99 | R454B/144.62 |
| Refrigerant Precharge Length (ft.) | 25 | 25 | 25 | 25 | 25 |
| Additional Charge for Each ft. (oz/ft) | 0.16 | 0.32 | 0.32 | 0.32 | 0.32 |
| Design Pressure (PSIG) | 550/340 | 550/340 | 550/340 | 550/340 | 550/340 |
| Refrigerant Piping (Liquid Side/Gas Side) (inch) | 1/4"×1/2" | 3/8"×5/8" | 3/8"×3/4" | 3/8"×3/4" | 3/8"×3/4" |
| Max. Pipe Length (ft.) | 98.40 | 164 | 246 | 246 | 246 |
| Max. Difference in Level (ft.) | 65.60 | 82 | 98.40 | 98.40 | 98.40 |
| Ambient Temperature - Cooling (°F) | -13~122 | -13~122 | -13~122 | -13~122 | -13~122 |
| Ambient Temperature - Heating (°F) | -13~75 | -13~75 | -13~75 | -13~75 | -13~75 |
| Certification - Standard 1 | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification - Standard 2 | ✔ | ✔ | ✔ | ✔ | ✔ |
| Certification - Standard 3 | ✔ | ✔ | ✔ | ✔ | ✔ |
Frequently asked questions.
What size mini split do I need for my space?
For effective cooling and heating, the Cooper & Hunter 60,000 BTU mini split is suitable for spaces up to 2,500 sq ft. This capacity makes it ideal for light commercial applications or larger residential areas.
How much does a mini split system like Cooper & Hunter cost?
The price of the Cooper & Hunter 60,000 BTU ductless mini split varies based on the installation kit selected, ranging from no kit to 50 ft options. Check our site for the most current pricing and promotional offers.
Can I install a mini split myself or do I need a professional?
While DIY installation is possible for the Cooper & Hunter system, it is recommended to have a professional install it to ensure proper setup and efficiency. This unit requires specific knowledge regarding refrigerant handling and electrical connections.
Does the Cooper & Hunter mini split come pre-charged with refrigerant?
Yes, the Cooper & Hunter 60,000 BTU mini split comes pre-charged with R454B refrigerant for up to 25 ft of line set. This feature simplifies installation as you won't need to add refrigerant immediately.
What voltage does the Cooper & Hunter mini split require?
The Cooper & Hunter 60,000 BTU ductless mini split operates on 230V. Ensure your electrical system can support this voltage to avoid installation issues.
What warranty does the Cooper & Hunter offer for this mini split?
The Cooper & Hunter 60,000 BTU mini split comes with a 5-year parts warranty and a 7-year compressor warranty, provided you register within 30 days of purchase. This warranty ensures long-term reliability and peace of mind.
Manufacturer Technical Support
Reach your brand's tech support team directly
You may also like
- R454BSEER2 21.5HEATS down to 5°FCOOLS up to 122°F
7-Yr Warranty
Cooper & HunterCooper & Hunter MIA 6,000 BTU Single Zone Wall Mount, 115V, R454B - Ductless Mini Split Air Conditioner Heat PumpFree Shipping
- R454BSEER2 21.2HEATS down to 5°FCOOLS up to 122°F
7-Yr Warranty
Cooper & HunterCooper & Hunter MIA 9,000 BTU Single Zone Wall Mount, 230V, R454B - Ductless Mini Split Air Conditioner Heat PumpFree Shipping
- R454BSEER2 21.2HEATS down to 5°FCOOLS up to 122°F
7-Yr Warranty
Cooper & HunterCooper & Hunter MIA 9,000 BTU Single Zone Wall Mount, 115V, R454B - Ductless Mini Split Air Conditioner Heat PumpFree Shipping
- R32HEATS down to 23°FCOOLS up to 109°F
1-Yr Warranty
Cooper & HunterCooper & Hunter 9,000 BTU PTAC Air Conditioner, Heat Pump, Heating and Cooling, w/Electric Cord and RemoteFree Shipping
The Cooper & Hunter 60,000 BTU (5 Ton) light commercial universal floor/ceiling unit is a single-zone mini split air conditioner and heat pump on next-generation R454B refrigerant that installs two ways: suspended flat under the ceiling or as a console at the base of the wall — no ductwork either way. With a 19.5 SEER2 inverter system on 208/230V, it cools and heats open spaces up to approximately 3,300 sq ft and keeps heating in outdoor temperatures as low as -13°F (rated 54,000 Btu/h cooling / 60,000 Btu/h heating). Wi-Fi control is built in.
Key Features
- 54,000 Btu/h cooling / 60,000 Btu/h heating — inverter range 15,000–54,500 cooling, 20,200–60,000 heating
- 19.5 SEER2 / 9.5 EER2 / 9.5 HSPF4 — current R454B-generation efficiency
- Heats down to -13°F outdoor ambient; cooling operation -13–122°F
- Universal 2-way installation — ceiling-suspended or floor-console mounting from one unit; long-throw airflow for large, open rooms
- Refrigerant leak sensor and humidity sensor (active on single-zone systems)
- Quiet: indoor unit from 38.5 dB(A); outdoor unit 63.5 dB(A)
- Wi-Fi Smart Kit built in — Cooper & Hunter app control; IR remote and 12V wall thermostat included (thermostat connection enables smart features)
- ETL listed, AHRI certified & NEEP listed
Cooper & Hunter Universal Floor/Ceiling (R454B) Lineup
| Capacity | Outdoor + Indoor Unit | SEER2 | Heats down to | Coverage* |
| 18,000 BTU | CH-RES18-230VO + CH-RSH18MFC | 22.3 | -13°F | up to 1,000 sq ft |
| 18,000 BTU Hyper Heat | CH-RHP18-230VO + CH-RSH18MFC | 20.4 | -22°F | up to 950 sq ft |
| 24,000 BTU | CH-RES24-230VO + CH-RSH24MFC | 21.1 | -13°F | up to 1,500 sq ft |
| 24,000 BTU Hyper Heat | CH-RHP24-230VO + CH-RSH24MFC | 20.4 | -22°F | up to 1,300 sq ft |
| 36,000 BTU LC | CH-R36LCU-230VO + CH-RSH36LCFC | 20.0 | -13°F | up to 2,200 sq ft |
| 36,000 BTU Hyper Heat LC | CH-RHP36LCU-230VO + CH-RSH36LCFC | 20.0 | -22°F | up to 2,200 sq ft |
| 48,000 BTU LC | CH-R48LCU-230VO + CH-RSH48LCFC | 19.8 | -13°F | up to 3,000 sq ft |
| 48,000 BTU Hyper Heat LC | CH-RHP48LCU-230VO + CH-RSH48LCFC | 18.5 | -22°F | up to 3,000 sq ft |
| 60,000 BTU LC | CH-R60LCU-230VO + CH-RSH60LCFC | 19.5 | -13°F | up to 3,300 sq ft |
| 60,000 BTU Hyper Heat LC | CH-RHP60LCU-230VO + CH-RSH60LCFC | 18.0 | -22°F | up to 3,300 sq ft |
*Coverage is sizing guidance; actual load depends on insulation, ceiling height, sun exposure, and climate. LC = Light Commercial.