HVAC Mart
Menu
(844) 558-6388

Monday–Friday, 9:00 AM – 5:00 PM EST

Cooper & Hunter Olivia Hyper Heat 24,000 BTU Single Zone Wall Mount, 230V, R454B - Ductless Mini Split Air Conditioner Heat Pump

SEER2 22.3HEATS down to −22°FCOOLS up to 122°FR454B

Cooper & Hunter7-Yr WarrantySKU: CH-RHP24-230VO24OLV

ASIN: B07HCM1KXW

$2,592.96
As low as $217/mo withaffirm
Product specifications
Voltage
230V
SEER
22.3
WiFi
Included
Zone
Single Zone
Type
Wall Mount
Freon
R454B
See full Tech Specs

Choose Your Configuration

Installation Kit: NO INSTALLATION KIT

“No Installation Kit” ships the units only.

Save 10% on these accessories

  • ARMBRIDGE Mini Split Wall Mounting Bracket High Load Capacity Zinc, Vibration-Absorbing (Up to 550 lbs Each)ARMBRIDGE Mini Split Wall Mounting Bracket High Load Capacity Zinc, Vibration-Absorbing (Up to 550 lbs Each)-10%$49.00
  • ARMBRIDGE Heavy-Duty Mini Split Ground Stand, Zinc-Coated Brackets for 24,000–60,000 BTU Units Weatherproof Design, 330+ lbs CapacityARMBRIDGE Heavy-Duty Mini Split Ground Stand, Zinc-Coated Brackets for 24,000–60,000 BTU Units Weatherproof Design, 330+ lbs Capacity-10%$89.00
  • ARMBRIDGE 30 AMP Fusible Metallic Disconnect Box Durable Enclosed Disconnect for Residential and Light Commercial HVAC SystemsARMBRIDGE 30 AMP Fusible Metallic Disconnect Box Durable Enclosed Disconnect for Residential and Light Commercial HVAC Systems-10%$29.00
  • ARMBRIDGE Non-Metallic A/C Whip 3/4" x 6 ft – Pre-Wired Liquid tight Conduit with 8/2 & 10/1 Wires for HVAC & Air Conditioner Power ConnectionARMBRIDGE Non-Metallic A/C Whip 3/4" x 6 ft – Pre-Wired Liquid tight Conduit with 8/2 & 10/1 Wires for HVAC & Air Conditioner Power Connection-10%$34.00
1

FREE Delivery

Ships from the nearest of our three US warehouses, leaves in 1–2 business days. Shipping policy

Warranty Included
30-Day Returns

COOPER & HUNTER · OLIVIA HYPER HEAT

Built for year-round comfort

Indoor unit

CH-RHP24-230VO24OLV

System Specs

Cooling Capacity23,000 BTU/h
Heating Capacity11,800–28,100 BTU/h
SEER222.3
EER212.5
Voltage230V
RefrigerantR454B
CompressorInverter
Climate Range-22–122°F / -22–75°F outdoor ambient
Sound Level (indoor)49.5/43.5/34.5 dB
Warranty7-Yr Compressor

Indoor Unit Specs

Unit Dimensions (WxDxH)Net / Gross WeightRemote Control
42.60 × 9.21 × 13.27 in30.86 / 40.56 lbRemote controller

Olivia Hyper Heat Series Description

The Cooper & Hunter Olivia Hyper Heat 24,000 BTU (2 Ton) wall mount mini split is a single-zone ductless air conditioner and heat pump on next-generation R454B refrigerant. The slim wall-mounted air handler suits bedrooms, living rooms, home offices, additions, and garages. With a 22.3 SEER2 inverter system on 208/230V, it cools and heats spaces up to approximately 1,400 sq ft and keeps heating in outdoor temperatures as low as -22°F (rated 23,000 Btu/h cooling as printed in the catalog — an honest rating slightly below the 24k nominal). Wi-Fi control is built in.

6 Modes for Maximum Comfort

Engineered to adapt to every season, every room, every need.

Auto mode

Maintain a comfortable indoor temperature by automatically switching between heating and cooling as needed. Ideal for year-round use.

WHEREVER YOU ARE

Control your comfort, your way

  • Easy scheduling & timer
  • Multiple ways to control your comfort
  • Smart geo location
  • In-app support & assistance
  • Voice control
Easy scheduling & timer
Package contents

IN THE BOX

Everything included with this system


  1. Cooper & Hunter Hyper 24,000 BTU Outdoor Condenser, 230V, R454B - Single Zone Mini Split Air Conditioner Heat Pump
  2. Indoor Wall Mount — CH-RB24MOLVWM-230VI
7YEAR COMPRESSOR
WARRANTY

BACKED BY COOPER & HUNTER

Industry-leading protection on every unit

  • Compressor: 7-year coverage

    With product registration after professional installation.

  • Parts & components: 5-year coverage

    All major components and refrigerant circuit parts.

Technical Specifications

Outdoor Unit Specs— CH-RHP24-230VO

Outdoor Unit — CH-RHP24-230VO
ModelCH-RHP24-230VO
Unit Dimensions (WxDxH)37.24 x 16.14 x 31.89 in
Net/Gross Weight130.29/141.31 lb
Packing Dimensions (WxDxH)42.91 x 19.68 x 34.84 in
Power Supply208-230V, 1Ph, 60Hz
Maximum Fuse Size25 A
Min. Circuit Ampacity24.9 A
Copper Line Size (Liquid/Gas)3/8"/5/8"
Noise Level61 dB
Airflow2,235.3 CFM
Dehumidification5.50 pt/h

Indoor Unit Specs

Indoor Unit — CH-R24MOLVWM-230VI, CH-RB24MOLVWM-230VI
ModelCH-R24MOLVWM-230VICH-RB24MOLVWM-230VI
Unit Dimensions (WxDxH)42.60 x 9.21 x 13.27 in
Net/Gross Weight30.86/40.56 lb
Packing Dimensions (WxDxH)45.47 x 16.34 x 12.40 in
Power Supply208-230V, 1Ph, 60Hz
Maximum Fuse Size15 A
Min. Circuit Ampacity3 A
Copper Line Size (Liquid/Gas)3/8"/5/8"
Noise Level (Hi/Med/Lo)49.5/43.5/34.5 dB
Dehumidification5.50 pt/h
Drain Pipe Diameter5/8"
Controllerremote controllerRG10K-exclusive remote
Indoor noise level (Hi/Med/Lo) (dB)48/40/28
SEER2 up to22.3
EER2 up to13.5
BTU Rated24,000
Power source208-230V, 1Ph, 60Hz
Operation room temperature Cooling (F)60~90
Operation room temperature Heating (F)32~86
Minimum circuit ampacity (A)3
Max. fuse (A)15
Voltage range (V)187-253
Unit dimensions (WxDxH)42.64x9.61x13.23
Packing dimensions (WxDxH)45.47x16.34x12.40
Net/Gross weight (lb)29.98/38.14
System typeSingle/Multi-zone unit
Refrigerant typeR454B
Refrigerant piping Liquid/Gas side (inch)3/8"/5/8"
Drainage water pipe diameter (inch)5/8"
Dehumidification (Pnt/H)5.43
Indoor Airflow (Turbo/Hi/Mi/Lo) (CFM)760.59/601.18/458.82/382.35

System Specs

System
Cooling — Rated Capacity (Range)23,000 Btu/h (16,800–24,500) (rated 23,000 Btu/h as printed — honest rating below the 24k nominal)
Heating Capacity Range (47°F)11,800–28,100 Btu/h
Rated Heating at 17°F (AHRI)24,400 Btu/h
SEER2 / EER222.3 / 12.5
HSPF4 / HSPF5 / COP (47°F)13.3 / 9.6 / 3.05
Outdoor Unit MCA / Max. Fuse24.9 A / 25 A
Indoor Unit MCA / Max. Fuse3 A / 15 A
Indoor Air Flow (Turbo/Hi/Mid/Lo)759.3 / 588.6 / 459.1 / 382.6 CFM
Indoor Noise Level (Turbo/Hi/Mid/Lo)54.5 / 49.5 / 43.5 / 34.5 dB(A)
Indoor Unit Dimensions (W×D×H)42.60 × 9.21 × 13.27 in
Indoor Unit Net / Gross Weight30.86 / 40.56 lbs
Outdoor Noise Level61.0 dB(A)
Outdoor Unit Dimensions (W×D×H)37.24 × 16.14 × 31.89 in
Outdoor Unit Net / Gross Weight130.29 / 141.31 lbs
Refrigerant Type / ChargeR454B / 63.49 oz
Pre-charged Line Length25 ft (add 0.32 oz per additional ft)
Line Set (Liquid / Gas)3/8" / 5/8"
Max. Pipe Length164 ft
Max. Elevation Difference82 ft
Operating Range — Cooling / Heating-22–122°F / -22–75°F outdoor ambient
Recommended Coverageup to 1,400 sq ft (guidance)

Series Comparison Table

Technical specifications for every model in the series — this product is one of them.

Indoor and Outdoor Hyper

SpecificationCH-R006MOLVWM-230VICH-R009MOLVWM-230VICH-R012MOLVWM-230VICH-R018MOLVWM-230VICH-R024MOLVWM-230VICH-R033HOLVWM-230VI
Power Supply Rated208/230, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60
Rated Capacity Btu/h6,0009,00012,00018,00023,00033,000
Minimum Circuit Ampacity (MCA) A333333
Max. Fuse A151515151515
Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) CFM294.3/225.4/176.8/141.3/NA382.6/293.1/194.2/153.0/NA382.6/293.1/194.2/153.0/NA759.3/530.4/419.1/382.6/NA759.3/586.5/419.1/382.6/NA829.6/716.6/592.7/447.3/NA
Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) dB(A)42.0/37.0/32.0/24.0/NA42.0/37.0/32.0/24.0/NA43.0/37.0/32.0/24.0/NA52.5/44.0/40.5/35.2/25.054.5/49.0/45.3/41.3/27.056.0/49.5/45.3/41.3/27.0
Dimension (WxDxH) inch28.7x7.87x11.8131.57x7.87x11.6131.57x7.87x11.6142.60x9.21x13.2742.60x9.21x13.2752.76x15.16x17.72
Packing (WxDxH) inch31.10x10.63x14.7634.45x11.22x14.9634.45x11.22x14.9645.47x12.40x16.3445.47x12.40x16.3452.76x15.16x17.72
Net/Gross Weight lbs.17.64/23.1518.96/24.2518.96/24.2530.42/39.6830.86/40.5667.16/17.72
Room temperature Cooling °F60~9060~9060~9060~9060~9060~90
Room temperature Heating °F32~8632~8632~8632~8632~8632~86
Liquid Side/Gas Side inch1/4" / 3/8"1/4" / 3/8"1/4" / 3/8"1/4" / 1/2"3/8" / 5/8"3/8" / 3/4"

Outdoor Model

SpecificationCH-RHP24-230VOThis modelCH-RHP06F9-230VOCH-RHP09-230VOCH-RHP12-230VOCH-RHP18-230VOCH-RHP33-230VO
Power Supply Rated V, Ph, Hz208/230, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60
Voltage Range V187-253187-253187-253187-253187-253187-253
Rated Capacity Range Btu/h16,000~24,5002,500~11,5003,600~13,5003,600~13,5008,400~20,20015,000~35,000
Cooling EER2 Btu/h12.516.015.013.213.011.7
SEER2 Btu/h22.325.326.024.021.719.5
Rated current A8.43.14.04.19.014.1
Heating at 47°F COP W/W3.053.803.633.633.543.22
HSPF413.314.612.510.510.810.5
HSPF59.611.210.18.08.88.3
Heating at 17°F (AHRI) Rated capacity Btu/h24,4008,60012,80012,80019,80030,200
Minimum Circuit Ampacity A24.91215151935
Max.Fuse (Outdoor Unit) A251515152040
Outdoor Air Flow (Max.) CFM2,235.31,235.31,470.61,470.61,764.72,235.3
Outdoor Noise Level (Sound Pressure) dB(A)61.053.056.056.059.063.5
Dimension (WxDxH) inch37.24x16.14x31.8930.12x11.93x21.8531.69x12.99x21.8131.69x12.99x21.8135.04x13.46x26.5037.44x19.09x34.84
Packing (WxDxH) inch42.91x19.69x34.8434.92x13.27x24.0236.02x14.57x24.2136.02x14.57x24.2139.17x15.67x29.1342.91x19.09x34.84
Net/Gross Weight lbs.130.29/141.3162.17/67.6872.75/78.7072.75/78.7099.87/107.80156.87/197.99
Refrigerant Type / Charge oz.R454B/63.49R454B/32.45R454B/35.27R454B/35.27R454B/55.38R454B/87.13
Refrigerant Precharge Length #252525252525
Additional Charge for Each ft. oz/ft0.320.160.160.160.160.32
Design Pressure PSIG550/340550/340550/340550/340550/340550/340
Refrigerant Piping Liquid Side/Gas Side inch3/8" / 5/8"1/4" / 3/8"1/4" / 3/8"1/4" / 3/8"1/4" / 1/2"3/8" / 3/4"
Max. Pipe Length ft.16482828298.4164
Max. Difference in Level ft.8249.249.249.265.682
Ambient Temperature Cooling °F-22~122-22~122-22~122-22~122-22~122-22~122
Heating °F-22~75-22~75-22~75-22~75-22~75-22~75
UL✓✓✓✓✓✓
AHRI✓✓✓✓✓✓
Energy Star✓✓✓✓✓✓
NEEP✓✓✓✓✓✓

Indoor and Outdoor Regular

SpecificationCH-R060LVWM-115VICH-R09OLVWM-115VICH-R120LVWM-115VICH-RO9MOLVWM-230VICH-R12MOLVWM-230VICH-R18MOLVWM-230VICH-R24MOLVWM-230VICH-R30MELVWM-230VICH-R36MELVWM-230VI
Power Supply Rated115V, 1, 60115V, 1, 60115V, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60
Rated Capacity Btu/h7,0009,00012,0009,00012,00018,00024,00030,00036,000
Minimum Circuit Ampacity (MCA) A333333333
Max. Fuse A333333333
Indoor Air Flow (Turbo/Hi/Mi/Lo/Si) CFM370/340/265/174/-378/340/265/174/-378/340/265/174/-382/294/194/153/-382/294/194/153/-759/530/419/382/-759/586/419/382/-871/716/547/447/-871/716/547/447/-
Indoor Noise Level (Turbo/Hi/Mi/Lo/Si) dB(A)44/40/35/26/-44/40/35/26/-44/40/35/26/-45/41/32/24/-45/41/32/24/-54/49/45/41/2754/49/45/41/2756/52/45/38/2256/52/45/38/22
Dimension (WxDxH) inch31.57x7.87x11.9531.57x7.87x11.9531.57x7.87x11.9531.57x7.87x11.9531.57x7.87x11.9545.47x12.01x16.3445.47x12.01x16.3449.57x11.14x14.2549.57x11.14x14.25
Packing (WxDxH) inch34.92x13.27x24.0234.92x13.27x24.0234.92x13.27x24.0234.92x13.27x24.0234.92x13.27x24.0242.91x19.09x34.8442.91x19.09x34.8442.91x19.09x34.8442.91x19.09x34.84
Net/Gross Weight lbs.18.64/22.0518.64/22.0518.64/22.0518.64/22.0518.64/22.0545.47/21.0645.47/21.0667.16/17.7267.16/17.72
Room temperature Cooling °F60~9060~9060~9060~9060~9060~9060~9060~9060~90
Room temperature Heating °F32~8632~8632~8632~8632~8632~8632~8632~8632~86
Liquid Side/Gas Side inch1/4" / 3/8"1/4" / 3/8"1/4" / 3/8"1/4" / 3/8"1/4" / 3/8"1/4" / 1/2"3/8" / 5/8"3/8" / 5/8"3/8" / 5/8"

Outdoor Model

SpecificationCH-RES06-115V0CH-RES09-115VOCH-RES12-115VOCH-RES09-230VOCH-RES12-230VOCH-RES18-230VOCH-RES24-230VOCH-REL30-230V0CH-REL36-230VO
Power Supply Rated V, Ph, Hz115, 1, 60115, 1, 60115, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60208/230, 1, 60
Voltage Range V103.5-126.5103.5-126.5103.5-126.5187-253187-253187-253187-253187-253187-253
Rated Capacity Range Btu/h2,600~13,0002,600~13,0003,100~19,0002,600~13,7002,600~13,7003,600~20,0009,700~32,7006,800~33,9006,600~36,800
Cooling EER2 Btu/h6.96.910.06.96.911.011.011.011.0
SEER2 Btu/h15.015.015.015.015.015.015.015.015.0
Rated current A6.96.912.010.010.011.011.011.011.0
Heating at 47°F COP W/W24.524.523.224.623.122.319.522.319.5
HSPF44,500~12,8004,500~12,80045,00~12,8004,200~14,2004,100~14,4007,600~22,00011,300~32,70011,300~32,10011,400~44,000
HSPF57.67.610.33.64.36.213.412.613.6
Heating at 17°F (AHRI) Rated capacity Btu/h8.28.27.69.58.58.37.77.07.0
Minimum Circuit Ampacity A8,6008,90010,2008,9009,90014,50021,30021,50025,600
Max.Fuse (Outdoor Unit) A202018121820253035
Outdoor Air Flow (Max.) CFM1,235.31,235.31,235.31,235.31,235.31,794.72,235.32,235.32,205.0
Outdoor Noise Level (Sound Pressure) dB(A)53.053.053.053.053.054.060.060.060.0
Dimension (WxDxH) inch30.12x11.93x21.8530.12x11.93x21.8530.12x11.93x21.8530.12x11.93x21.8530.12x11.93x21.8535.04x13.46x26.5037.24x16.14x31.8937.24x16.14x31.8937.24x16.14x31.89
Packing (WxDxH) inch34.92x13.27x24.0234.92x13.27x24.0234.92x13.27x24.0234.92x13.27x24.0234.92x13.27x24.0239.17x15.67x29.1342.91x19.09x34.8442.91x19.09x34.8442.91x19.09x34.84
Net/Gross Weight lbs.64.59/70.1164.59/70.1164.59/70.1164.59/70.1164.59/70.1192.59/107.60128.17/132.28142.86/154.84150.35/160.27
Refrigerant Type / Charge oz.R454B/33.51R454B/33.51R454B/33.51R454B/32.45R454B/32.45R454B/47.97R454B/70.55R454B/84.66R454B/112.88
Refrigerant Precharge Length #252525252525252525
Additional Charge for Each ft. oz/ft0.160.160.160.160.160.320.320.320.32
Design Pressure PSIG550/340550/340550/340550/340550/340550/340550/340550/340550/340
Refrigerant Piping Liquid Side/Gas Side inch1/4" / 3/8"1/4" / 3/8"1/4" / 3/8"1/4" / 3/8"1/4" / 3/8"1/4" / 1/2"3/8" / 5/8"3/8" / 5/8"3/8" / 5/8"
Max. Pipe Length ft.828282828298.4164164213.2
Max. Difference in Level ft.49.249.249.249.249.265.6828298.4
Ambient Temperature Cooling °F-13~122-13~122-13~122-13~122-13~122-13~122-13~122-13~122-13~122
Heating °F-13~75-13~75-13~75-13~75-13~75-13~75-13~75-13~75-13~75
UL✓✓✓✓✓✓✓✓✓
AHRI✓✓✓✓✓✓✓✓✓
Energy Star✓✓✓✓✓✓✓✓✓
NEEP✓✓✓✓✓✓✓✓

Frequently asked questions.

What size mini split do I need for my home?

For spaces up to 1,200 sq ft, the Cooper & Hunter Olivia Hyper Heat 24,000 BTU mini split is ideal. Its 24k BTU capacity ensures effective cooling and heating for larger rooms.

Can I install a mini split myself?

While some homeowners may attempt a DIY installation, the Cooper & Hunter Olivia Hyper Heat system, with its 230V requirement and up to 25 ft of line set, is best installed by a professional. Proper installation ensures efficiency and adherence to warranty terms.

Does the mini split come pre-charged with refrigerant?

Yes, the Cooper & Hunter Olivia Hyper Heat system comes pre-charged with R454B refrigerant for installations with up to 25 ft of line set. This feature simplifies the installation process and ensures optimal performance.

What voltage does a mini split require?

The Cooper & Hunter Olivia Hyper Heat operates on a 230V electrical system. Ensure your electrical supply matches this requirement for proper functionality.

What warranty does the Cooper & Hunter Olivia Hyper Heat offer?

The Cooper & Hunter Olivia Hyper Heat comes with a 5-year parts warranty and a 7-year compressor warranty, provided you register within 30 days of purchase. This warranty reflects the brand's commitment to quality and durability.

What is the SEER rating of the Cooper & Hunter Olivia Hyper Heat?

The Cooper & Hunter Olivia Hyper Heat boasts an impressive SEER rating of 22.3, making it highly efficient for both cooling and heating. This efficiency can significantly lower your energy bills compared to lower-rated systems.

Talk to a Sales Specialist

Not sure which system is right for your space? Our experts help with sizing and installation questions.

Mon – Fri, 8 AM – 5 PM (PST)

Get Support

Manufacturer Technical Support

Reach your brand's tech support team directly

Cooper & Hunter


(888) 201-2119

Olmo Comfort


(800) 977-0724

You may also like

The Cooper & Hunter Olivia Hyper Heat 24,000 BTU (2 Ton) wall mount mini split is a single-zone ductless air conditioner and heat pump on next-generation R454B refrigerant. The slim wall-mounted air handler suits bedrooms, living rooms, home offices, additions, and garages. With a 22.3 SEER2 inverter system on 208/230V, it cools and heats spaces up to approximately 1,400 sq ft and keeps heating in outdoor temperatures as low as -22°F (rated 23,000 Btu/h cooling as printed in the catalog — an honest rating slightly below the 24k nominal). Wi-Fi control is built in.

Key Features

  • 23,000 Btu/h rated cooling — inverter cooling range 16,800–24,500 Btu/h; heating capacity range 11,800–28,100 Btu/h at 47°F
  • 24,400 Btu/h AHRI rated heating at 17°F — certified low-ambient heat output
  • 22.3 SEER2 / 12.5 EER2 / 13.3 HSPF4 — current R454B-generation efficiency
  • Hyper Heat: heats down to -22°F outdoor ambient; cooling operation -22–122°F
  • Auto-swing horizontal louvers with Turbo Mode, Follow Me mode, Sleep Mode, and Timer On/Off
  • Self-Cleaning and Eco modes (active on single-zone systems); 46°F freeze-protection function
  • Quiet: indoor unit from 34.5 dB(A) with Genius Core ultra-low 12Hz compressor speeds; outdoor unit 61.0 dB(A)
  • Wi-Fi Smart Kit built in — Cooper & Hunter app control; remote control included; compatible with C&H 12V wall thermostat (sold separately)
  • ETL listed, AHRI certified, Energy Star Cold Climate & NEEP listed

Cooper & Hunter Olivia Wall Mount (R454B) Lineup

Capacity Outdoor + Indoor Unit SEER2 Heats down to Coverage*
6,000 BTU Hyper Heat CH-RHP06F9-230VO + CH-R06MOLVWM-230VI 25.3 -22°F up to 300 sq ft
9,000 BTU CH-RES09-230VO + CH-R09MOLVWM-230VI 24.6 -13°F up to 400 sq ft
9,000 BTU Hyper Heat CH-RHP09-230VO + CH-R09MOLVWM-230VI 26.0 -22°F up to 400 sq ft
12,000 BTU CH-RES12-230VO + CH-R12MOLVWM-230VI 23.1 -13°F up to 550 sq ft
12,000 BTU (115V) CH-RES12-115VO + CH-R12OLVWM-115VI 23.2 -13°F up to 550 sq ft
12,000 BTU Hyper Heat CH-RHP12-230VO + CH-R12MOLVWM-230VI 24.0 -22°F up to 550 sq ft
18,000 BTU CH-RES18-230VO + CH-R18MOLVWM-230VI 24.0 -13°F up to 1,000 sq ft
18,000 BTU Hyper Heat CH-RHP18-230VO + CH-R18MOLVWM-230VI 21.7 -22°F up to 1,000 sq ft
24,000 BTU CH-RES24-230VO + CH-R24MOLVWM-230VI 23.5 -13°F up to 1,500 sq ft
24,000 BTU Hyper Heat CH-RHP24-230VO + CH-R24MOLVWM-230VI 22.3 -22°F up to 1,400 sq ft
30,000 BTU CH-REL30-230VO + CH-R30MELVWM-230VI 22.3 -13°F up to 1,800 sq ft
36,000 BTU CH-REL36-230VO + CH-R36MELVWM-230VI 19.5 -13°F up to 2,200 sq ft

*Coverage is sizing guidance; actual load depends on insulation, ceiling height, sun exposure, and climate.

Cart

Add $300.00 more for FREE shipping!

Your cart is empty

Looks like you haven't added anything yet.